A four-layer depth of interaction detector block for small animal PET
…, T Omura, H Kawai, N Inadama… - … on Nuclear Science, 2004 - ieeexplore.ieee.org
We are now planning to develop a positron emission tomograph dedicated to small animals,
such as rats and mice, which meets the demand for higher sensitivity. For the positron …
such as rats and mice, which meets the demand for higher sensitivity. For the positron …
A proposal of an open PET geometry
…, S Minohara, E Yoshida, N Inadama… - Physics in Medicine …, 2008 - iopscience.iop.org
The long patient port of a PET scanner tends to put stress on patients, especially patients with
claustrophobia. It also prevents doctors and technicians from taking care of patients during …
claustrophobia. It also prevents doctors and technicians from taking care of patients during …
Development of a small prototype for a proof-of-concept of OpenPET imaging
…, H Tashima, F Nishikido, N Inadama… - Physics in Medicine …, 2011 - iopscience.iop.org
The OpenPET geometry is our new idea to visualize a physically opened space between
two detector rings. In this paper, we developed the first small prototype to show a proof-of-…
two detector rings. In this paper, we developed the first small prototype to show a proof-of-…
A SiPM-based isotropic-3D PET detector X'tal cube with a three-dimensional array of 1 mm3 crystals
…, T Mitsuhashi, T Matsumoto, N Inadama… - Physics in Medicine …, 2011 - iopscience.iop.org
We are developing a novel, general purpose isotropic-3D PET detector X'tal cube which has
high spatial resolution in all three dimensions. The research challenge for this detector is …
high spatial resolution in all three dimensions. The research challenge for this detector is …
Development of a small single-ring OpenPET prototype with a novel transformable architecture
H Tashima, E Yoshida, N Inadama… - Physics in Medicine …, 2016 - iopscience.iop.org
The single-ring OpenPET (SROP), for which the detector arrangement has a cylinder shape
cut by two parallel planes at a slant angle to form an open space, is our original proposal for …
cut by two parallel planes at a slant angle to form an open space, is our original proposal for …
Performance evaluation of a subset of a four-layer LSO detector for a small animal DOI PET scanner: jPET-RD
…, H Murayama, K Kitamura, N Inadama… - IEEE transactions on …, 2006 - ieeexplore.ieee.org
Previously, we proposed a new depth of interaction (DOI) encoding method and proved that
it worked successfully with four-layered Gd/sub 2/SiO/sub 5/ crystals for a small animal …
it worked successfully with four-layered Gd/sub 2/SiO/sub 5/ crystals for a small animal …
Annihilation photon acollinearity in PET: volunteer and phantom FDG studies
…, T Suzuki, T Tsuda, N Inadama… - Physics in Medicine …, 2007 - iopscience.iop.org
Annihilation photon acollinearity is a fundamental but little investigated problem in positron
emission tomography (PET). In this paper, the cause of the angular deviation from 180.00 is …
emission tomography (PET). In this paper, the cause of the angular deviation from 180.00 is …
Transaxial system models for jPET-D4 image reconstruction
…, H Haneishi, E Yoshida, N Inadama… - Physics in Medicine …, 2005 - iopscience.iop.org
A high-performance brain PET scanner, jPET-D4, which provides four-layer depth-of-interaction
(DOI) information, is being developed to achieve not only high spatial resolution, but …
(DOI) information, is being developed to achieve not only high spatial resolution, but …
A depth of interaction detector for PET with GSO crystals doped with different amounts of Ce
N Inadama, H Murayama, T Omura… - … on Nuclear Science, 2002 - ieeexplore.ieee.org
A new method for a four-stage depth of interaction (DOI) detector is proposed. The four-stage
DOI detector is constructed with two kinds of Gd/sub 2/SiO/sub 5/:Ce (GSO) crystals doped …
DOI detector is constructed with two kinds of Gd/sub 2/SiO/sub 5/:Ce (GSO) crystals doped …
Preliminary resolution performance of the prototype system for a 4-layer DOI-PET scanner: jPET-D4
…, T Hasegawa, H Haneishi, N Inadama… - IEEE transactions on …, 2006 - ieeexplore.ieee.org
We are developing a high-performance brain PET scanner, jPET-D4, which provides 4-layer
depth-of-interaction (DOI) information. The scanner is designed to achieve not only high …
depth-of-interaction (DOI) information. The scanner is designed to achieve not only high …