User profiles for Matthew G. Spangler-Bickell
Matthew Spangler-BickellGE HealthCare Verified email at ge.com Cited by 267 |
Ultra-fast list-mode reconstruction of short PET frames and example applications
MG Spangler-Bickell, TW Deller… - Journal of Nuclear …, 2021 - Soc Nuclear Med
Standard clinical reconstructions usually require several minutes to complete, and this time
is mostly independent of the duration of the data being reconstructed. Applications such as …
is mostly independent of the duration of the data being reconstructed. Applications such as …
Rigid motion correction for brain PET/MR imaging using optical tracking
MG Spangler-Bickell, MM Khalighi… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
A significant challenge during high-resolution PET brain imaging on PET/MR scanners is
patient head motion. This challenge is particularly significant for clinical patient populations …
patient head motion. This challenge is particularly significant for clinical patient populations …
[HTML][HTML] The effect of isoflurane on 18F-FDG uptake in the rat brain: a fully conscious dynamic PET study using motion compensation
Background In preclinical positron emission tomography (PET) studies an anaesthetic is used
to ensure that the animal does not move during the scan. However, anaesthesia may have …
to ensure that the animal does not move during the scan. However, anaesthesia may have …
Evaluation of data-driven rigid motion correction in clinical brain PET imaging
MG Spangler-Bickell, SA Hurley… - Journal of Nuclear …, 2022 - Soc Nuclear Med
Head motion during brain PET imaging can significantly degrade the quality of the reconstructed
image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-…
image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-…
Optimising rigid motion compensation for small animal brain PET imaging
Motion compensation (MC) in PET brain imaging of awake small animals is attracting increased
attention in preclinical studies since it avoids the confounding effects of anaesthesia and …
attention in preclinical studies since it avoids the confounding effects of anaesthesia and …
Optimizing the frame duration for data‐driven rigid motion estimation in brain PET imaging
Purpose Data‐driven rigid motion estimation for PET brain imaging is usually performed
using data frames sampled at low temporal resolution to reduce the overall computation time …
using data frames sampled at low temporal resolution to reduce the overall computation time …
An Event-Driven Subsetting Approach for Accelerated PET List-Mode Reconstruction
TW Deller, MG Spangler-Bickell… - … on Radiation and …, 2023 - ieeexplore.ieee.org
PET iterative reconstruction typically employs subsetting to reduce computation time. List
mode PET data provides flexibility for subsetting approaches, but optimization of list mode …
mode PET data provides flexibility for subsetting approaches, but optimization of list mode …
Effect of image noise on registration in PET brain imaging
MG Spangler-Bickell, T Deller… - 2019 IEEE Nuclear …, 2019 - ieeexplore.ieee.org
Rigid image registration techniques can be used in PET imaging to align frames acquired
during a brain scan where motion may or may not have been present during the scan. The …
during a brain scan where motion may or may not have been present during the scan. The …
Implementation and image quality benefit of a hybrid-space PET point spread function
…, KA Wangerin, MG Spangler-Bickell… - 2021 IEEE Nuclear …, 2021 - ieeexplore.ieee.org
High resolution PET imaging is being driven by recent advances in both scanner hardware
and image reconstruction. As a result, images are being reconstructed with smaller pixel …
and image reconstruction. As a result, images are being reconstructed with smaller pixel …
A solution to PET brain motion artefact
KM Bradley, TW Deller, MG Spangler-Bickell… - Journal of …, 2021 - Springer
Head movement during PET acquisition degrades image quality and may render studies
non-diagnostic. Rebinning of the list mode data to reconstruct optimised images from a …
non-diagnostic. Rebinning of the list mode data to reconstruct optimised images from a …