User profiles for Matthew G. Spangler-Bickell

Matthew Spangler-Bickell

GE HealthCare
Verified email at ge.com
Cited by 267

Ultra-fast list-mode reconstruction of short PET frames and example applications

MG Spangler-Bickell, TW Deller… - Journal of Nuclear …, 2021 - Soc Nuclear Med
Standard clinical reconstructions usually require several minutes to complete, and this time
is mostly independent of the duration of the data being reconstructed. Applications such as …

Rigid motion correction for brain PET/MR imaging using optical tracking

MG Spangler-Bickell, MM Khalighi… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
A significant challenge during high-resolution PET brain imaging on PET/MR scanners is
patient head motion. This challenge is particularly significant for clinical patient populations …

[HTML][HTML] The effect of isoflurane on 18F-FDG uptake in the rat brain: a fully conscious dynamic PET study using motion compensation

MG Spangler-Bickell, B de Laat, R Fulton, G Bormans… - EJNMMI research, 2016 - Springer
Background In preclinical positron emission tomography (PET) studies an anaesthetic is used
to ensure that the animal does not move during the scan. However, anaesthesia may have …

Evaluation of data-driven rigid motion correction in clinical brain PET imaging

MG Spangler-Bickell, SA Hurley… - Journal of Nuclear …, 2022 - Soc Nuclear Med
Head motion during brain PET imaging can significantly degrade the quality of the reconstructed
image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-…

Optimising rigid motion compensation for small animal brain PET imaging

MG Spangler-Bickell, L Zhou, AZ Kyme… - Physics in Medicine …, 2016 - iopscience.iop.org
Motion compensation (MC) in PET brain imaging of awake small animals is attracting increased
attention in preclinical studies since it avoids the confounding effects of anaesthesia and …

Optimizing the frame duration for data‐driven rigid motion estimation in brain PET imaging

MG SpanglerBickell, SA Hurley, TW Deller… - Medical …, 2021 - Wiley Online Library
Purpose Data‐driven rigid motion estimation for PET brain imaging is usually performed
using data frames sampled at low temporal resolution to reduce the overall computation time …

An Event-Driven Subsetting Approach for Accelerated PET List-Mode Reconstruction

TW Deller, MG Spangler-Bickell… - … on Radiation and …, 2023 - ieeexplore.ieee.org
PET iterative reconstruction typically employs subsetting to reduce computation time. List
mode PET data provides flexibility for subsetting approaches, but optimization of list mode …

Effect of image noise on registration in PET brain imaging

MG Spangler-Bickell, T Deller… - 2019 IEEE Nuclear …, 2019 - ieeexplore.ieee.org
Rigid image registration techniques can be used in PET imaging to align frames acquired
during a brain scan where motion may or may not have been present during the scan. The …

Implementation and image quality benefit of a hybrid-space PET point spread function

…, KA Wangerin, MG Spangler-Bickell… - 2021 IEEE Nuclear …, 2021 - ieeexplore.ieee.org
High resolution PET imaging is being driven by recent advances in both scanner hardware
and image reconstruction. As a result, images are being reconstructed with smaller pixel …

A solution to PET brain motion artefact

KM Bradley, TW Deller, MG Spangler-Bickell… - Journal of …, 2021 - Springer
Head movement during PET acquisition degrades image quality and may render studies
non-diagnostic. Rebinning of the list mode data to reconstruct optimised images from a …