Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the …

H Iida, I Kanno, S Miura, M Murakami… - Journal of Cerebral …, 1986 - journals.sagepub.com
The effect of the inaccuracy of the input function on CBF measured by the H 15 2 O autoradiographic
method was investigated. In H 15 2 O autoradiography the measured input function …

Reduction in regional cerebral metabolic rate of oxygen during human aging.

…, F Shishido, A Inugami, T Ogawa, M Murakami… - Stroke, 1986 - Am Heart Assoc
To investigate changes in cerebral circulation and oxygen metabolism during aging, regional
cerebral blood flow (rCBF), regional oxygen extraction fraction (rOEF), regional cerebral …

Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume …

H Iida, I Kanno, A Takahashi, S Miura, M Murakami… - Circulation, 1988 - Am Heart Assoc
An in vivo technique was developed for measuring the absolute myocardial blood flow with
H215O and dynamic positron-emission tomography. This technique was based on a new …

[PDF][PDF] Re-evaluation of amino acid PET studies: can the protein synthesis rates in brain and tumor tissues be measured in vivo?

K Ishiwata, K Kubota, M Murakami… - Journal of Nuclear …, 1993 - Soc Nuclear Med
Tritium-3-Met (specificactivityof 7.3 GBq/mmol) was pur chased from Du Pont-NEN Research
Products (Wilmington, DE) and 14C-Leu (specific activity of 1.92 GBq/mmol) from ICN Bio …

Clinical positron emission tomography for brain tumors: comparison of fludeoxyglucose F 18 and L-methyl-11C-methionine.

…, J Hatazawa, I Kanno, M Murakami… - American journal …, 1996 - Am Soc Neuroradiology
PURPOSE To evaluate the differences between fludeoxyglucose F 18 (FDG) and L-methyl-11C-methionine
(11C-methionine) as tracers for positron emission tomography (PET) in the …

Age-related decline of cerebral oxygen metabolism in normal population detected with positron emission tomography

…, A Inugami, H Fujita, T Ogawa, M Murakami… - Neurological …, 1992 - Taylor & Francis
Using positron emission tomography (PET), cerebral blood flow (CBF) and cerebral metabolic
rate of oxygen (CMR02) were measured in 32 healthy volunteers aged from 27 to 67 years…

Methionine PET for follow-up of radiation therapy of primary lymphoma of the brain.

…, A Inugami, H Fujita, E Shimosegawa, M Murakami… - Radiographics, 1994 - pubs.rsna.org
Positron emission tomography (PET) with carbon-11 methionine, computed tomography (CT),
and magnetic resonance (MR) imaging were performed in 10 patients with histologically …

Potential radiopharmaceuticals labeled with titanium-45

K Ishiwata, T Ido, M Monma, M Murakami… - International journal of …, 1991 - Elsevier
The potential of some compounds labeled with cyclotron-produced titanium-45 ( 45 Ti) as
radiopharmaceuticals was studied. Properties of colloid formation of 45 TiOCl 2 or 45 TiO-…

Oxygen Extraction Fraction at Maximally Vasodilated Tissue in the Ischemic Brain Estimated from the Regional CO2 Responsiveness Measured by Positron Emission …

…, K Uemura, S Higano, M Murakami… - Journal of Cerebral …, 1988 - journals.sagepub.com
The oxygen extraction fraction (OEF) at maximally vasodilated tissue in patients with chronic
cerebrovascular disease was evaluated using positron emission tomography. The vascular …

A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

…, M Munaka, S Higano, M Murakami… - European journal of …, 1994 - Springer
A method has been developed to quantitate regional cerebral blood blow (rCBF) using
iodine-123-labelled N-isopropyl-p-iodoamphetamine (IMP). This technique requires only two …