[PDF][PDF] Elimination of liver interference from the selenomethionine pancreas scan

E Kaplan, M Ben-Porath, S Fink… - Journal of Nuclear …, 1966 - Soc Nuclear Med
RESULTS The results of scanning the model system described above may be visualized in
Figure three. The 75Sewithin the inner plastic bottle may be visualized clearly when the †…

[PDF][PDF] The biological half-life of 75Se-selenomethionine in man

M Ben-Porath, L Case, E Kaplan - Journal of Nuclear Medicine, 1968 - Soc Nuclear Med
F1G. 1. ThSedisappearancecurvesin normals and lymphomas (averages). approximates 8
days, and while it is of the same order of magnitude as the half-time of serum protein and may …

Treatment of thyrotoxicosis with 125I and 131I

Z Lewitus, E Lubin, J Rechnic, M Ben-Porath… - Seminars in Nuclear …, 1971 - Elsevier
The mode of decay of 125 I, which emits in the course of its transmutation cascades of low-energy
Auger electrons of a high linear energy transfer (LET), explains its radiobiologic …

[PDF][PDF] Modification of a multi-isotope color scanner for multi-purpose scanning

M Ben-Porath, G Clayton, E Kaplan - Journal of Nuclear Medicine, 1967 - Soc Nuclear Med
In recent publications from our laboratories, a technique using dual pulse height analyzer
count rate systems has been described for electronic subtraction of one gamma photopeak …

Radioiodine uptake by the infarcted heart

F Dreyfuss, M Ben-Porath, J Menczel - The American Journal of Cardiology, 1960 - Elsevier
An increased uptake of radioiodine by the infarcted heart has been reported by us
previously. Forty-nine patients have now been investigated: twenty-three patients with recent …

[PDF][PDF] Current status of dual-channel pancreas scanning

S Fink, M Ben-Porath, B Jacobson… - Journal of Nuclear …, 1969 - Soc Nuclear Med
21 11). This detector was first placed over the right lobe of the liver remote from the pancreas.
Gamma rays of different energies from the two isotopes were discriminated by two pulse-…

DUAL CHANNEL SCANNING.

E Kaplan, M Ben-Porath - 1969 - osti.gov
Subject: N28530*-Life Sciences-Medicine-Radiodiagnosis; DIAGNOSIS; DISEASES;
GLANDS; GOLD 198; MAN; MEDICINE; PANCREAS; RATE METERS; SCINTILLATION …

[PDF][PDF] A Comparison of Iodine-125 and Iodine-131 as Tracers in the Diagnosis of Thyroid Disease. I. Physical Aspects

MB Porath, A Hochman, J Gross - Journal of Nuclear Medicine, 1966 - Soc Nuclear Med
Myers and Vanderleeden(1) first pointed out that the physical proper ties of 1251provided
certain advantages over the commonly used 1311as a diag nostic tracer both in vivo and in …

[PDF][PDF] Tape recording of dual-channel energy-modulated color scanning

M Ben-Porath, GD Clayton… - Journal of Nuclear …, 1969 - Soc Nuclear Med
BEN-PORATH, CLAYTON AND KAPLAN area of overlap is seen in white, effectively revealing
the distribution boundary of each isotope in the mdi vidual organs. The production of …

[PDF][PDF] The distribution and concentration of 75Se-selenomethionine in man

M Ben-Porath, E Kaplan - Journal of Nuclear Medicine, 1969 - Soc Nuclear Med
2¾X 2¾X @ X 8in. is availablefrom the author upon request. RR CAVALIERI Page 1
LETTERS TO THE EDITOR LOW-COSTPRECISIONLINEARSCANNING TABLE The …