Radiation dosimetry in nuclear medicine

MG Stabin, M Tagesson, SR Thomas… - Applied Radiation and …, 1999 - Elsevier
Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic
procedures. A knowledge of the radiation dose received by different organs in the body is …

OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine

MG Stabin, RB Sparks, E Crowe - Journal of nuclear medicine, 2005 - Soc Nuclear Med
The OLINDA/EXM version 1.0 personal computer code was created as a replacement for the
widely used MIRDOSE3.1 code. This paper documents the basic function of the code and …

Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources—1950–2007

…, JA Lipoti, M Mahesh, JL McCrohan, MG Stabin… - Radiology, 2009 - pubs.rsna.org
The US National Council on Radiation Protection and Measurements and United Nations
Scientific Committee on Effects of Atomic Radiation each conducted respective assessments of …

Procedure guideline for tumor imaging with 18F-FDG PET/CT 1.0

…, JA Parker, K Hubner, MG Stabin… - Journal of nuclear …, 2006 - Soc Nuclear Med
… material should not be administered when the serum creatinine level is above 2.0 mg/dL. …
Most institutions reschedule the patient if the blood glucose level is greater than 150–200 mg/…

[PDF][PDF] MIRD pamphlet no. 16: techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates

…, SR Thomas, JB Stubbs, MG Stabin… - Journal of Nuclear …, 1999 - Soc Nuclear Med
Theabsorbedradiationdosefrominternallydepositedradio nuclides is a major factor in assessing
risk and therapeutic utility when evaluating new radiopharmaceuticals for use in nuclear …

[BOOK][B] Radiation protection and dosimetry

MG Stabin - 2007 - Springer
… From Chapter 4, we recall that the range in mg/cm2 of electrons of energy E is given as …
ln(2.27) = 1090 mg/cm2. The thickness of Lucite needed is thus: …

[PDF][PDF] Breast milk excretion of radiopharmaceuticals: mechanisms, findings, and radiation dosimetry

MG Stabin, HB Breitz - Journal of Nuclear Medicine, 2000 - Soc Nuclear Med
… The radiation dose was calculated using S values for breast-to breast from the adult female
model of Stabin et al. (45). The … •Stabin and Breitz … Stabin MG. Radiation dose from breast …

Physical models and dose factors for use in internal dose assessment

MG Stabin, JA Siegel - Health physics, 2003 - journals.lww.com
… with myriads of equations that have confused many potential users, the basic equations
used for performing internal dose calculations are all essentially compatible ( Stabin 1996a ). In …

SNM practice guideline for sodium 18F-fluoride PET/CT bone scans 1.0

G Segall, D Delbeke, MG Stabin… - Journal of Nuclear …, 2010 - Soc Nuclear Med
The Society of Nuclear Medicine (SNM) is an international scientific and professional
organization founded in 1954 to promote the science, technology, and practical application of …

SNMMI and EANM practice guideline for meckel diverticulum scintigraphy 2.0

…, AH Maurer, JE Seabold, MG Stabin… - Journal of nuclear …, 2014 - Soc Nuclear Med
… Intravenous administration: 50 μg/kg intravenously, to a maximum of 1 mg, diluted to a
volume of 10 mL with sterile water, infused slowly over 2 min immediately before injection of the …