Heart imaging with cationic complexes of technetium

…, KA Glavan, RC Elder, VJ Sodd, KL Scholz… - Science, 1981 - science.org
The cationic technetium-99 complex trans-[ 99 TC(dmpe) 2 Cl 2 ] + , where dmpe is bis(1,2-dimethylphosphino)ethane
or (CH 3 ) 2 P-CH 2 CH 2 -P(CH 3 ) 2 , has been prepared and …

[PDF][PDF] Basal kinetic studies of Tc-99m DMPE as a myocardial imaging agent in the dog

…, DL Fortman, KL Scholz… - Journal of Nuclear …, 1982 - Soc Nuclear Med
Basal Kinetic Studiesof Tc-99m DMPEas a MyocardiaiImagingAgent in the Dog Page 1
CLINICALSCIENCES The early results of our continuing search for Tc 99m labeled myocardial …

Cyclotron production of rhodium-101m through its precursor palladium-101

KL Scholz, VJ Sodd, JW Blue - … Journal of Applied Radiation and Isotopes, 1977 - Elsevier
The preparation of high-purity 101m Rh through its natural precursor, 101 Pd was investigated.
The 103 Rh(p,3n) 101 Pd and natural Pd (p,xn) 101 Ag → 101 Pd ; Pd (p,pxn) 101 Pd …

Production of Thulium-167 for medical use by irradiation of letetium, hafnium, tantalum and tungsten with 590-MeV protons

KL Scholz, VJ Sodd, JW Blue - … Journal of Applied Radiation and Isotopes, 1976 - Elsevier
The feasibility of producing high-purity 167 Tm by spallation for use in nuclear medicine
was investigated. Lutetium-oxide powder and hafnium, tantalum and tungsten foils were …

[PDF][PDF] Synthesis and kinetics of [18F] 4′-fluoroantipyrine in normal mice

PJ Robbins, DL Fortman, KL Scholz… - Journal of Nuclear …, 1978 - Soc Nuclear Med
There has been considerable interest in the de velopment of Fi 8-labeled radiopharmaceuticals
be cause of the short physical half-life of Fi 8 (109.8 mm) and its ability to be imaged with …

Mechanics of faulting

CH Scholz - Annual Review of Earth and Planetary Sciences, 1989 - annualreviews.org
… zone can develop (Cox & Scholz 1988a,b). Initially a … L, where L is a critical slip distance
required for friction to change in response to a step velocity change (Gu et aI1984). If K < Ken

Analysis of tritium in water: a collaborative study

VJ Sodd, KL Scholz - Journal of the Association of Official …, 1969 - academic.oup.com
A liquid scintillation procedure using 1,4-dioxane, naphthalene, PPO, and POPOP as the
scintillator was evaluated in a collaborative study of the determination of tritium in water. The …

Nuclide parameters and S factors for 201Tl dosimetry estimates

PA Feller, KL Scholz - Medical Physics, 1976 - Wiley Online Library
The mean numbers per disintegration, n, and equilibrium‐dose constants Δ for the various
emissions of 201 Tl were computed. The sums of the penetrating and nonpenetrating …

Film reciprocity law failure in scintillation camera imaging.

LW Grossman, RJ Van Tuinen, JB Kruger, KL Scholz - Radiology, 1981 - pubs.rsna.org
Sensitometric measurements of scintillation camera images show that substantial changes
in film response occur with variations in imaging time or dot focus. Both the speed and the …

Spallation production of 127Cs-129Cs mixtures for medical use

KL Scholz, VJ Sodd, JW Blue - … Journal of Applied Radiation and Isotopes, 1974 - Elsevier
The feasibility of producing 127 Cs- 129 Cs mixtures by spallation for use in nuclear
medicine was investigated. It is possible to use this mixture since the energies of the principal …