Improvement in lesion detection with whole-body oncologic time-of-flight PET

…, S Surti, CM Trott, J Scheuermann… - Journal of Nuclear …, 2011 - Soc Nuclear Med
Time-of-flight (TOF) PET has great potential in whole-body oncologic applications, and
recent work has demonstrated qualitatively in patient studies the improvement that can be …

Accuracy of [18F]Fluorodopa Positron Emission Tomography for Diagnosing and Localizing Focal Congenital Hyperinsulinism

…, JR Saffer, JS Scheuermann… - The Journal of …, 2007 - academic.oup.com
Objectives: Focal lesions in infants with congenital hyperinsulinism (HI) represent areas of
adenomatosis that express a paternally derived ATP-sensitive potassium channel mutation …

Qualification of PET scanners for use in multicenter cancer clinical trials: the American College of Radiology Imaging Network experience

JS Scheuermann, JR Saffer, JS Karp… - Journal of Nuclear …, 2009 - Soc Nuclear Med
The PET Core Laboratory of the American College of Radiology Imaging Network (ACRIN)
qualifies sites to participate in multicenter research trials by quantitatively reviewing …

Impact of time-of-flight PET on whole-body oncologic studies: a human observer lesion detection and localization study

S Surti, J Scheuermann, G El Fakhri… - Journal of Nuclear …, 2011 - Soc Nuclear Med
Phantom studies have shown improved lesion detection performance with time-of-flight (TOF)
PET. In this study, we evaluate the benefit of fully 3-dimensional, TOF PET in clinical whole-…

Performance evaluation of the SiPM-based Siemens Biograph Vision PET/CT system

JS Reddin, JS Scheuermann… - 2018 Ieee nuclear …, 2018 - ieeexplore.ieee.org
The Siemens Biograph Vision PET/CT is a SiPM-based scanner composed of detector blocks
consisting of 5x5 arrays of 3.2x3.2x20mm 3 LSO crystals coupled to a 4x4 SiPM array. The …

Biodistribution and dosimetry of 18F-EF5 in cancer patients with preliminary comparison of 18F-EF5 uptake versus EF5 binding in human glioblastoma

CJ Koch, JS Scheuermann, C Divgi, KD Judy… - European journal of …, 2010 - Springer
Purpose The primary purpose of this study was to assess the biodistribution and radiation
dose resulting from administration of 18 F-EF5, a lipophilic 2-nitroimidazole hypoxia marker in …

Preliminary Evaluation of 68Ga-P16-093, a PET Radiotracer Targeting Prostate-Specific Membrane Antigen in Prostate Cancer

H Lee, JS Scheuermann, AJ Young, RK Doot… - Molecular Imaging and …, 2022 - Springer
Purpose Prostate-specific membrane antigen (PSMA) is a promising molecular target for
imaging of prostate adenocarcinoma. Ga-P16-093, a small molecule PSMA ligand, previously …

The effect of breathing irregularities on quantitative accuracy of respiratory gated PET/CT

…, B Saboury, R Munbodh, J Scheuermann… - Medical …, 2012 - Wiley Online Library
Purpose: 4D positron emission tomography and computed tomography (PET/CT) can be
used to reduce motion artifacts by correlating the raw PET data with the respiratory cycle. The …

Qualification of National Cancer Institute–Designated Cancer Centers for Quantitative PET/CT Imaging in Clinical Trials

JS Scheuermann, JS Reddin… - Journal of Nuclear …, 2017 - Soc Nuclear Med
The National Cancer Institute developed the Centers for Quantitative Imaging Excellence (CQIE)
initiative in 2010 to prequalify imaging facilities at all of the National Cancer Institute–…

Development and evaluation of an automatic interstitial catheter digitization tool for adaptive high-dose-rate brachytherapy

J Dise, X Liang, J Scheuermann, S Anamalayil… - Brachytherapy, 2015 - Elsevier
Purpose To develop and evaluate an automatic interstitial catheter digitization algorithm for
use in adaptive high-dose-rate brachytherapy for gynecologic cancers using the Syed-…