Paramagnetic complexes of manganese (II), iron (III), and gadolinium (III) as contrast agents for magnetic resonance imaging: the influence of stability constants on the …

D FORNASIERO, JC BELLEN, RJ BAKER… - Investigative …, 1987 - journals.lww.com
Fornasiero D, Bellen JC, Baker RJ, Chatterton BE. Paramagnetic complexes of manganese (II),
iron (III), and gadolinium (III) as contrast agents for magnetic resonance imaging: the …

[PDF][PDF] Gallium-67 complexes as radioactive markers to assess gastric and colonic transit

JC Bellen, BE Chatterton, S Penglis… - Journal of Nuclear …, 1995 - Soc Nuclear Med
67-EDTA showed &rrHiarpartitioningin the lIquidphase of the gastñcemi*@ ingmodel
compared w@ i 11@ In-DWA Conclusion: Gallium-67-citrateis an economicaland readily …

Kit preparation of technetium-99m-mercaptoacetyltriglycine: analysis, biodistribution and comparison with technetium-99m-DTPA in patients with impaired renal …

KM Bannister, S Penglis, JC Bellen… - Journal of Nuclear …, 1990 - europepmc.org
Technetium-99m-mercaptoacetyltriglycine (99mTc-MAG3) was prepared by a frozen solution
method, enabling the preparation of kits yielding a product substantially free of lipophilic …

[PDF][PDF] Technetium-99m calcium phytate—optimization of calcium content for liver and spleen scintigraphy: concise communication

J Campbell, JC Bellen, RJ Baker… - Journal of Nuclear …, 1981 - Soc Nuclear Med
MATERIALS AND METHODS Kit preparation. Kits were prepared containing the equivalent
of 20 mg anhydrous sodium phytate* and 1.0 mg SnCI2. 2H2O in 0.5 ml water for injection at …

[PDF][PDF] Segmental colonic transit after oral 67Ga-citrate in healthy subjects and those with chronic idiopathic constipation

…, BE Chatterton, JC Bellen… - Journal of Nuclear …, 1999 - Soc Nuclear Med
24hr 48hr 72hr underwent 67Ga-citratestudies and 10 patients (median age 43 y; age range
34— 68y) underwent †œIn-DTPAstudies. All of these subjects had a history of chronic …

The Preparation of 99mTc—Tertiarybutylisonitrile (99mTc-TBI) by a method suitable for routine clinical use

RJ Baker, JC Bellen, D Fornasiero, S Penglis - International Journal of …, 1986 - Elsevier
The myocardial imaging agent technetium-99m-hexakis (tertiarybutylisonitrile) ( 99m Tc-TBI)
was prepared by the reaction of [ 99m Tc]pertechnetate with TBI in 50% ethanol/0.9% saline …

Studies of 99mTc-acylplasmins as agents for thrombus detection

RJ Baker, AB McLaren, J Campbell, JC Bellen… - European Journal of …, 1985 - Springer
It has been proposed that acylation at the active site of plasmin is able to prevent its reaction
with α2-antiplasmin without affecting the fibrin affinity of the enzyme. To investigate the …

The effect of lipophilic substituents on the biological properties of EDTA complexes containing paramagnetic metal ions

RJ Baker, AB McLaren, JC Bellen, S Penglis - International Journal of …, 1987 - Elsevier
Complexes of the radioactive paramagnetic metal ions 51 Cr(III), 54 Mn(II), 59 Fe(III), 57 Co(II),
64 Cu(II) and 153 Gd(III) were prepared with EDTA and its derivative containing the …

A comparison of radiolabelled agents for thrombus imaging using a rabbit model

J Campbell, JC Bellen, RJ Baker… - International Journal of …, 1986 - Elsevier
The quantitative uptakes of five potential thrombus-localizing radiopharmaceuticals in
experimental thrombi of the rabbit jugular vein have been compared to assist with the selection of …

[PDF][PDF] ofSamotusandSchwimmer (5)(RK Barnes, personal

J Campbell, JC Bellen, RJ Baker, DJ Cook - Citeseer
MATERIALS AND METHODS Kit preparation. Kits were prepared containing the equivalent
of 20 mg anhydrous sodium phytate* and 1.0 mg SnCI2. 2H2O in 0.5 ml water for injection at …