Simultaneous reconstruction of activity and attenuation in time-of-flight PET

A Rezaei, M Defrise, G Bal, C Michel… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
In positron emission tomography (PET) and single photon emission tomography (SPECT),
attenuation correction is necessary for quantitative reconstruction of the tracer distribution. …

Completion of a truncated attenuation image from the attenuated PET emission data

J Nuyts, G Bal, F Kehren, M Fenchel… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
Positron emission tomographs (PETs) are currently almost exclusively designed as hybrid
systems. The current standard is the PET/CT combination, while prototype PET/MRI systems …

Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging—a simulation study

Z Cao, G Bal, R Accorsi, PD Acton - Physics in Medicine & …, 2005 - iopscience.iop.org
This study simulates a multi-pinhole single-photon emission computed tomography (SPECT)
system using the Monte Carlo method, and investigates different multi-pinhole designs for …

Physical performance of adaptive axial FOV PET scanners with a sparse detector block rings or a checkerboard configuration

…, MH Nehmeh, M Conti, G Bal… - Physics in Medicine …, 2022 - iopscience.iop.org
Objective. Using Monte-Carlo simulations, we evaluated the physical performance of a
hypothetical state-of-the-art clinical PET scanner with adaptive axial field-of-view (AFOV) based …

Analytical derivation of the point spread function for pinhole collimators

G Bal, PD Acton - Physics in Medicine & Biology, 2006 - iopscience.iop.org
The point spread function (PSF) of a pinhole collimator plays an important role in determining
the resolution and characterizing the sensitivity of the accepted photons from a given point …

Simultaneous reconstruction of activity and attenuation in time-of-flight PET

A Rezaei, J Nuyts, M Defrise, G Bal… - 2011 IEEE Nuclear …, 2011 - ieeexplore.ieee.org
In positron emission tomography (PET) and single photon emission tomography (SPECT),
attenuation correction is necessary for quantitative reconstruction of the tracer distribution. …

Attenuation correction for rotating slant-hole (RSH) SPECT using exact rebinning

JM Wagner, F Noo, R Clackdoyle, G Bal… - IEEE Transactions on …, 2003 - ieeexplore.ieee.org
We have recently derived an analytic method of image reconstruction for the rotating slant-hole
(RSH) SPECT scanner for cardiac imaging. The method assumes that the emission …

Clinical evaluation of MLAA for MR-PET

G Bal, F Kehren, C Michel, C Watson, D Manthey… - 2011 - Soc Nuclear Med
263 Objectives The new Siemens Biograph mMR whole-body MR-PET uses the simultaneously
acquired MR images for PET attenuation correction. As with most CT/MR generated mu-…

Revolving multipinhole SPECT for small animal imaging

G Bal, PD Acton, F Jansen… - 2008 IEEE Nuclear …, 2008 - ieeexplore.ieee.org
Multi-pinhole collimators are often used to obtain the detection sensitivity necessary for small
animal SPECT with submillimeter spatial resolution. However, in comparison to pinhole …

Studying effects of missing data for clinical TOF PET

G Bal, V Panin, I Huff, C Michel… - 2018 IEEE Nuclear …, 2018 - ieeexplore.ieee.org
Up to recently, accounting for missing data in PET reconstruction has been used to rescue (remove
artifacts and restore quantitation on) studies when a few block detectors were out of …