User profiles for Floris Jansen
Floris JansenGE Healthcare Verified email at ge.com Cited by 1136 |
Design features and mutual compatibility studies of the time-of-flight PET capable GE SIGNA PET/MR system
A recent entry into the rapidly evolving field of integrated PET/MR scanners is presented in
this paper: a whole body hybrid PET/MR system (SIGNA PET/MR, GE Healthcare) capable of …
this paper: a whole body hybrid PET/MR system (SIGNA PET/MR, GE Healthcare) capable of …
[HTML][HTML] Image enhancement of whole-body oncology [18F]-FDG PET scans using deep neural networks to reduce noise
Purpose To enhance the image quality of oncology [ 18 F]-FDG PET scans acquired in shorter
times and reconstructed by faster algorithms using deep neural networks. Methods List-…
times and reconstructed by faster algorithms using deep neural networks. Methods List-…
[HTML][HTML] Deep learning–based time-of-flight (ToF) image enhancement of non-ToF PET scans
Purpose To improve the quantitative accuracy and diagnostic confidence of PET images
reconstructed without time-of-flight (ToF) using deep learning models trained for ToF image …
reconstructed without time-of-flight (ToF) using deep learning models trained for ToF image …
The future of SPECT in a time of PET
FP Jansen, JL Vanderheyden - Nuclear medicine and biology, 2007 - Elsevier
As positron emission tomography (PET) imaging is becoming more prevalent in clinical
practice, it is reasonable to ask if there will be a role for single photon emission computed …
practice, it is reasonable to ask if there will be a role for single photon emission computed …
Rigid motion correction for brain PET/MR imaging using optical tracking
…, G Zaharchuk, M Zeineh, F Jansen - IEEE transactions on …, 2018 - ieeexplore.ieee.org
A significant challenge during high-resolution PET brain imaging on PET/MR scanners is
patient head motion. This challenge is particularly significant for clinical patient populations …
patient head motion. This challenge is particularly significant for clinical patient populations …
Ultra-fast list-mode reconstruction of short PET frames and example applications
Standard clinical reconstructions usually require several minutes to complete, and this time
is mostly independent of the duration of the data being reconstructed. Applications such as …
is mostly independent of the duration of the data being reconstructed. Applications such as …
Joint estimation of activity and attenuation for PET using pragmatic MR-based prior: application to clinical TOF PET/MR whole-body data for FDG and non-FDG tracers
…, H Qian, SS Kaushik, FP Jansen… - Physics in Medicine …, 2018 - iopscience.iop.org
Accurate and robust attenuation correction remains challenging in hybrid PET/MR particularly
for torsos because it is difficult to segment bones, lungs and internal air in MR images. …
for torsos because it is difficult to segment bones, lungs and internal air in MR images. …
[HTML][HTML] PET image reconstruction using physical and mathematical modelling for time of flight PET-MR scanners in the STIR library
This work demonstrates how computational and physical modelling of the positron emission
tomography (PET) image acquisition process for a state-of-the-art integrated PET and …
tomography (PET) image acquisition process for a state-of-the-art integrated PET and …
Clinical evaluation of whole-body oncologic PET with time-of-flight and point-spread function for the hybrid PET/MR system
…, B Cui, J Ma, D Shuai, Z Liang, F Jansen… - European Journal of …, 2017 - Elsevier
Purpose Hybrid positron emission tomography/magnetic resonance (PET/MR) imaging is a
new multimodality imaging technology that can provide structural and functional information …
new multimodality imaging technology that can provide structural and functional information …
Optimizing the frame duration for data‐driven rigid motion estimation in brain PET imaging
Purpose Data‐driven rigid motion estimation for PET brain imaging is usually performed
using data frames sampled at low temporal resolution to reduce the overall computation time …
using data frames sampled at low temporal resolution to reduce the overall computation time …