Direct relationship between proton T2 and exercise intensity in skeletal muscle MR images

…, GR ADAMS, JM FOLEY, EJ POTCHEN - Investigative …, 1990 - journals.lww.com
Exercise selectively increases the signal intensities (SI) of active muscles in T2-weighted
magnetic resonance (MR) images. If these SI increases are graded with exercise intensity, the …

Three-dimensional phase-contrast MR angiography in the head and neck: preliminary report.

JR Pernicone, JE Siebert, EJ Potchen… - … American journal of …, 1990 - Am Roentgen Ray Soc
Morbidity and possible mortality associated with contrast angiography lead to its cautious
use. A noninvasive method for screening and further delineating known abnormalities would …

Different effects of exercise and edema on T2 relaxation in skeletal muscle

…, S Nyren, TG Cooper, EJ Potchen… - Magnetic resonance …, 1997 - Wiley Online Library
The hypothesis that increased muscle T 2 after exercise is caused by increased extracellular
fluid volume was tested by comparing the effects of exercise versus external leg negative …

Measuring performance in chest radiography

EJ Potchen, TG Cooper, AE Sierra, GR Aben… - Radiology, 2000 - pubs.rsna.org
PURPOSE: To use a standardized set of chest radiographs to quantify interobserver
differences and to provide a basis for comparing the diagnostic performance of physicians. …

[PDF][PDF] Assessment of hepatic respiratory excursion

PH Weiss, JM Baker, EJ Potchen - Journal of Nuclear Medicine, 1972 - Soc Nuclear Med
MATERIALS AND METHODS Direct estimation of hepatic excursion. Hepatic excursion was
studied in a group of 25 patients re ferred to the Mallinckrodt Institute for liver scans. Scans …

Measuring observer performance in chest radiology: some experiences

EJ Potchen - Journal of the American College of Radiology, 2006 - Elsevier
All decisions made under conditions of uncertainty have error rates. All meaningful
decisions are made under conditions of uncertainty. Can this uncertainty be measured? Can …

Readability of the radiologic report

…, MA Bisesi, TL Rosenbaum, EJ Potchen - Investigative …, 1992 - journals.lww.com
Sierra AE, Bisesi MA., Rosenbaum TL, Potchen EJ. Readability of the radiologic report. Invest
Radiol 1992; 27: 236–239. To objectively assess the linguistic complexity of radiographic …

When is it malpractice to miss lung cancer on chest radiographs?

EJ Potchen, MA Bisesi - Radiology, 1990 - pubs.rsna.org
Case I (Fig 1)-A 66-year-old male smoker came to the emergency department because of
cough and shortness of breath. A chest radiograph was interpreted as negative except for left …

[PDF][PDF] Measurement of effective renal plasma flow in man by external counting methods

MD Blaufox, EJ Potchen, JP Merrill - Journal of Nuclear Medicine, 1967 - Soc Nuclear Med
DISCUSSION The results obtained in this study confirm the correlation between single
injection plasma clearances of OIH 1311and standard PAH clearances. The ratio of 0.91 of OIH/…

Effect of irradiation on tumor microvascular permeability to macromolecules

EJ Potchen, J Kinzie, C Curtis, BA Siegel, RK Studer - Cancer, 1972 - Wiley Online Library
In C3H mouse Gardner lymphosarcoma, we have demonstrated an increase in the extravascular
albumin space 48 hours after delivering 3,000 rads of irradiation. This observation has …