Diagnostic value of PET/CT for the staging and restaging of pediatric tumors

…, R Goldsby, Y Lu, T Schuster, C Schreck… - European journal of …, 2009 - Springer
Objective The objective of this retrospective study was to compare the diagnostic value of 2-[
18 F]fluoro-2-deoxy-d-glucose positron emission tomography ( 18 F-FDG PET)/CT versus …

A unique method by which to quantitate synchrony with equilibrium radionuclide angiography

JW O'Connell, C Schreck, M Moles, N Badwar… - Journal of Nuclear …, 2005 - Springer
Background Cardiac resynchronization therapy (CRT) improves symptoms and the survival
rate in patients with advanced heart failure by improving synchrony. However, CRT is not …

Inter-scanner differences in in vivo QCT measurements of the density and strength of the proximal femur remain after correction with anthropomorphic standardization …

RD Carpenter, I Saeed, S Bonaretti, C Schreck… - Medical engineering & …, 2014 - Elsevier
In multicenter studies and longitudinal studies that use two or more different quantitative
computed tomography (QCT) imaging systems, anthropomorphic standardization phantoms (…

Mapping of lymphatic drainage from the prostate using filtered 99mTc-sulfur nanocolloid and SPECT/CT

…, CP Chen, C Hsu, N Kased, C Schreck… - Journal of Nuclear …, 2011 - Soc Nuclear Med
We have developed a practice procedure for prostate lymphoscintigraphy using SPECT/CT
and filtered 99m Tc-sulfur nanocolloid, as an alternative to the proprietary product 99m Tc-…

Quantitative accuracy of PET/CT for image‐based kinetic analysis

Y Seo, BK Teo, M Hadi, C Schreck… - Medical …, 2008 - Wiley Online Library
Accuracy in quantification of activity concentrations (eg, in ) is essential for compartment
modeling and kinetic analysis of dynamic reconstructed PET images. Dynamic PET data can be …

Utility of equilibrium gated radionuclide angiography to guide coronary sinus lead placement in heart failure patients requiring cardiac resynchronization therapy

…, M Viswanathan, J O'Connell, T DeMarco, C Schreck… - 2006 - Soc Nuclear Med
1 Objectives: The equilibrium radionuclide angiogram (ERNA) provides an assessment of
left ventricular function and the location of dyssynchrony. We compared using the findings …

P5-45: Novel scintigraphic parameters to assess left ventricular dyssynchrony predict clinical response in patients requiring cardiac resynchronization therapy

…, JW O'Connell, M Vishwanathan, C Schreck… - Heart …, 2006 - heartrhythmjournal.com
Background The equilibrium radionuclide angiogram (ERNA) is an imaging method that
can be used to assess left ventricular (LV) function and synchrony. Each pixel of an ERNA is …

Novel scintigraphic parameters to assess left ventricular dyssynchrony predict clinical response in heart failure patients requiring cardiac resynchronization therapy

NI Badhwar, J O'Connell, M Viswanathan, C Schreck… - 2006 - Soc Nuclear Med
357 Objectives: The equilibrium radionuclide angiogram (ERNA) is an imaging method that
can be used to assess left ventricular (LV) function and synchrony. Each pixel of an ERNA is …

FDG PET for assessing response to therapy in patients with cervical cancer

D Carlson, C Schreck, MH Pampaloni - 2012 - Soc Nuclear Med
1334 Objectives To demostrate the value of FDG PET/CT in determining response to
treatment in patients with cervical cancer. Methods Thirty-three patients with pathology proven …

Regadenoson assessment of quantitative myocardial blood flow with (13) N ammonia PET/CT: Preliminary experience

MH Pampaloni, E Botvinick, C Schreck… - 2012 - Soc Nuclear Med
1815 Objectives Regadenoson is a selective widely used A2A adenosine receptor agonist
for pharmacologic myocardial perfusion imaging. However, clinical data of regadenoson with …