First determination of the heart-to-mediastinum ratio using cardiac dual isotope (123I-MIBG/99mTc-tetrofosmin) CZT imaging in patients with heart failure: the …

…, N Roth, T Blaire, C Desmonts, A Bailliez… - European journal of …, 2015 - Springer
Purpose Cardiac innervation is assessed using the heart-to-mediastinum ratio (HMR) of
metaiodobenzylguanidine (MIBG) on planar imaging using Anger single photon emission …

Quantitation of myocardial 99mTc-HMDP uptake with new SPECT/CT cadmium zinc telluride (CZT) camera in patients with transthyretin-related cardiac amyloidosis …

D Bellevre, A Bailliez, F Delelis, T Blaire… - Journal of Nuclear …, 2022 - Elsevier
Background The aim of this study was to investigate the feasibility of assessing absolute
myocardial 99mTc-HMDP uptake in patients with suspected cardiac ATTR using SUV with a …

First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study

T Blaire, A Bailliez, F Ben Bouallegue… - Journal of Nuclear …, 2018 - Springer
Background We studied the impact of simultaneous dual-isotope acquisition on 123 I/ 99m
Tc mismatch assessment using two CZT cameras (DNM 530c, GE Healthcare and DSPECT, …

Left ventricular function assessment using 2 different cadmium-zinc-telluride cameras compared with a γ-camera with cardiofocal collimators: dynamic cardiac …

A Bailliez, O Lairez, C Merlin, N Piriou… - Journal of Nuclear …, 2016 - Soc Nuclear Med
This study compared two SPECT cameras with cadmium-zinc-telluride (CZT) detectors to a
conventional Anger camera with cardiofocal collimators for the assessment of left ventricular (…

First follow-up of cardiac amyloidosis treated by tafamidis, evaluated by absolute quantification in bone scintigraphy

D Bellevre, A Bailliez, S Maréchaux, A Manrique… - JACC: Case …, 2021 - Elsevier
Assessment of absolute myocardial hydroxydimethylene diphosphonate–technetium-99m
uptake using standardized uptake value with a single-photon emission computed tomography…

Determination of the heart-to-mediastinum ratio of 123I-MIBG uptake using dual-isotope (123I-MIBG/99mTc-tetrofosmin) multipinhole cadmium-zinc-telluride SPECT in …

T Blaire, A Bailliez, FB Bouallegue… - Journal of Nuclear …, 2018 - Soc Nuclear Med
The aim of this retrospective study was to compare the heart-to-mediastinum ratio (HMR) of
123 I-metaiodobenzylguanidine ( 123 I-MIBG) uptake obtained using a multipinhole cadmium…

First comparison of performances between the new whole-body cadmium–zinc–telluride SPECT-CT camera and a dedicated cardiac CZT camera for myocardial …

…, C Hossein-Foucher, A Manrique, A Bailliez - Journal of Nuclear …, 2020 - Elsevier
Background Dedicated cardiac Cadmium–zinc–telluride (CZT) cameras show superior
performances compared with Anger systems, particularly in terms of spatial resolution and count …

Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and …

A Bailliez, T Blaire, F Mouquet, R Legghe… - Journal of Nuclear …, 2014 - Elsevier
… Author links open overlay panel Alban Bailliez MD a d , Tanguy Blaire MD a d , Frédéric
Mouquet MD, PhD b , R. Legghe MD a , B. Etienne MD a , Damien Legallois MD c d , Denis …

[HTML][HTML] Left ventricular function assessment using 123I/99mTc dual-isotope acquisition with two semi-conductor cadmium–zinc–telluride (CZT) cameras: a gated …

T Blaire, A Bailliez, FB Bouallegue, D Bellevre… - EJNMMI physics, 2016 - Springer
Background The impact of increased energy resolution of cadmium–zinc–telluride (CZT)
cameras on the assessment of left ventricular function under dual-isotope conditions ( 99m Tc …

Somatostatin receptor scintigraphy to predict the clinical evolution and therapeutic response of thyroid-associated ophthalmopathy

M Nocaudie, A Bailliez, E Itti, C Bauters… - European journal of …, 1999 - Springer
Management of thyroid-associated ophthalmopathy remains a topic of controversy.
Immunosuppressive treatments have to be applied at peak disease activity and before criteria of …