Tissue distribution and radiation dosimetry of astatine-211-labeled chimeric 81C6, an alpha-particle-emitting immunoconjugate

Nucl Med Biol. 1997 Apr;24(3):255-61. doi: 10.1016/s0969-8051(97)00060-7.

Abstract

A paired-label study was performed in athymic mice bearing subcutaneous D-54 MG human glioma xenografts to compare the localization of human/mouse anti-tenascin chimeric antibody 81C6 labeled by reaction with N-succinimidyl 3-[211At]astatobenzoate and N-succinimidyl 3-[131I]iodobenzoate. Over the 48-h observation period, the distribution of 211At- and 131I-labeled antibody were quite similar in tumor and normal tissues except stomach. These data were used to calculate human radiation doses for both intravenously and intrathecal administered 211At-labeled chimeric 81C6 using a quality factor of 5 for alpha-emissions.