Incremental diagnostic value of dobutamine stress echocardiography and dobutamine scintigraphy (technetium 99m-labeled sestamibi single-photon emission computed tomography) for assessment of presence and extent of coronary artery disease

J Nucl Cardiol. 1996 May-Jun;3(3):212-20. doi: 10.1016/s1071-3581(96)90035-5.

Abstract

Background: The incremental diagnostic value of dobutamine stress echocardiography (DSE) and 99mTc-labeled sestamibi single-photon emission computed tomography for the evaluation of the presence and extent of coronary artery disease (CAD) was assessed with ordered logistic regression and receiver-operating characteristic curves.

Methods and results: Forty-five consecutive patients (33 men and 12 women; 53 +/- 6.8 years) underwent exercise electrocardiography and simultaneous DSE and sestamibi single-photon emission computed tomographic imaging. Coronary angiography was performed in all patients (significant coronary stenosis > 50%). On the basis of the results of exercise electrocardiography, the pretest probability for CAD (Diamond's algorithm) was low (45.6% +/- 12.7%). According to ordered logistic regression analysis, some models were estimated that performed a diagnostic accuracy level for CAD. In particular, we evaluated a clinical model (model 1) determined by the following parameters: sex, age, presence of chest pain, and positivity of electrocardiogram during dobutamine stress test. This model was 64.3% +/- 10.7% accurate for the prediction of CAD. The addition to model 1 of DSE parameters (wall motion stress and rest score index and relative difference) (model 2) yielded a diagnostic accuracy of 81.4% +/- 4.3% (p < 0.045), whereas the addition to model 1 of single-photon emission computed tomographic parameters (the difference between perfusional stress and rest score index) (model 3) improved diagnostic accuracy to 92.3% +/- 5.5% (p < 0.003), a level that appeared significantly higher than that of model 2 (p < 0.016).

Conclusion: Both noninvasive methods for the detection of CAD showed a good diagnostic accuracy, especially when test-derived parameters were combined with clinical data. Nevertheless, the single-photon emission computed tomographic model showed a higher sensitivity compared with the DSE model.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Angina Pectoris / diagnosis
  • Angina Pectoris / physiopathology
  • Cardiotonic Agents*
  • Coronary Angiography / drug effects
  • Coronary Circulation / drug effects
  • Coronary Circulation / physiology
  • Coronary Disease / diagnosis*
  • Coronary Disease / physiopathology
  • Dobutamine*
  • Echocardiography*
  • Electrocardiography / drug effects
  • Exercise Test* / drug effects
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted
  • Male
  • Middle Aged
  • ROC Curve
  • Technetium Tc 99m Sestamibi*
  • Tomography, Emission-Computed, Single-Photon*

Substances

  • Cardiotonic Agents
  • Dobutamine
  • Technetium Tc 99m Sestamibi