Scintimammography: the complementary role of Tc-99m sestamibi prone breast imaging for the diagnosis of breast carcinoma

Radiology. 1995 Aug;196(2):421-6. doi: 10.1148/radiology.196.2.7617855.

Abstract

Purpose: To evaluate the complementary role of technetium-99m sestamibi scintimammography in improvement of the sensitivity and specificity of mammography in detection of carcinoma of the breast.

Materials and methods: At 5 and 60 minutes after intravenous injection of Tc-99m sestamibi, scintimammograms were obtained in 147 women (age range, 18-73 years; mean age, 47.9 years +/- 10.2 [standard deviation]) with 153 lesions that warranted breast biopsy (102 lesions) or fine-needle aspiration cytologic analysis (51 lesions). There were 113 palpable and 40 nonpalpable lesions. Lesion size on mammograms was 0.8 x 0.6 cm to 15.0 x 11.0 cm (mean, 2.82 cm +/- 1.71 x 2.39 cm +/- 1.56).

Results: Scintimammographic findings were true-positive in 47 biopsy-confirmed carcinomas, true-negative in 91 benign lesions, false-positive in 11 lesions with benign histopathologic findings (fibrocystic disease [n = 8] or fibroadenoma [n = 3]), and false-negative in four lesions of infiltrating ductal carcinoma. The sensitivity of scintimammography was 92.2%; specificity, 89.2%; positive predictive value, 81.0%; and negative predictive value, 95.8%.

Conclusion: The authors conclude that scintimammography is a sensitive test that can improve the detection of breast carcinoma.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biopsy, Needle
  • Breast / pathology
  • Breast Neoplasms / diagnostic imaging*
  • Breast Neoplasms / pathology
  • Carcinoma in Situ / diagnostic imaging*
  • Carcinoma in Situ / pathology
  • Carcinoma, Ductal, Breast / diagnostic imaging*
  • Carcinoma, Ductal, Breast / pathology
  • False Negative Reactions
  • False Positive Reactions
  • Female
  • Fibrocystic Breast Disease / diagnostic imaging
  • Fibrocystic Breast Disease / pathology
  • Humans
  • Middle Aged
  • Predictive Value of Tests
  • Prone Position
  • Radionuclide Imaging
  • Sensitivity and Specificity
  • Technetium Tc 99m Sestamibi*