Recurrent prostate cancer detection with anti-3-[(18)F]FACBC PET/CT: comparison with CT

Eur J Nucl Med Mol Imaging. 2016 Sep;43(10):1773-83. doi: 10.1007/s00259-016-3383-8. Epub 2016 Apr 18.

Abstract

Purpose: To compare the diagnostic performance of the synthetic amino acid analogue PET radiotracer anti-3-[(18)F]FACBC (fluciclovine) with that of CT in the detection of recurrent prostate carcinoma.

Methods: This was a retrospective analysis of 53 bone scan-negative patients with suspected recurrent prostate carcinoma who underwent fluciclovine PET/CT and routine clinical CT within 90 days of each other. The correlation between imaging findings and histology and clinical follow-up was evaluated. Positivity rates and diagnostic performance were calculated for fluciclovine PET/CT and CT.

Results: Of 53 fluciclovine PET/CT and 53 CT examinations, 41 (77.4 %) and 10 (18.9 %), respectively, had positive findings for recurrent disease. Positivity rates were higher with fluciclovine PET/CT than with CT at all prostate-specific antigen (PSA) levels, PSA doubling times and original Gleason scores. In the prostate/bed, fluciclovine PET/CT was true-positive in 31 and CT was true-positive in 4 of 51 patients who met the reference standard. In extraprostatic regions, fluciclovine PET/CT was true-positive in 12 and CT was true-positive in 3 of 41 patients who met the reference standard. Of the 43 index lesions used to prove positivity, 42 (97.7 %) had histological proof. In 51 patients with sufficient follow-up to calculate diagnostic performance in the prostate/bed, fluciclovine PET/CT demonstrated a sensitivity of 88.6 %, a specificity of 56.3 %, an accuracy of 78.4 %, a positive predictive value (PPV) of 81.6 %, and a negative predictive value (NPV) of 69.2 %; the respective values for CT were 11.4 %, 87.5 %, 35.3 %, 66.7 % and 31.1 %. In 41 patients with sufficient follow-up to calculate diagnostic performance in extraprostatic regions, fluciclovine PET/CT demonstrated a sensitivity of 46.2 %, a specificity of 100 %, an accuracy of 65.9 %, a PPV of 100 %, and an NPV of 51.7 %; the respective values for CT were 11.5 %, 100 %, 43.9 %, 100 % and 39.5 %.

Conclusion: The diagnostic performance of fluciclovine PET/CT in recurrent prostate cancer is superior to that of CT and fluciclovine PET/CT provides better delineation of prostatic from extraprostatic recurrence.

Keywords: CT; Diagnostic performance; FACBC; Fluciclovine; PET; Prostate cancer.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Bone Neoplasms / diagnostic imaging*
  • Bone Neoplasms / secondary*
  • Carboxylic Acids*
  • Cyclobutanes*
  • Humans
  • Image Enhancement / methods
  • Male
  • Middle Aged
  • Neoplasm Recurrence, Local / diagnostic imaging*
  • Neoplasm Recurrence, Local / prevention & control
  • Positron Emission Tomography Computed Tomography / methods*
  • Prostatic Neoplasms / diagnostic imaging*
  • Prostatic Neoplasms / pathology
  • Prostatic Neoplasms / surgery
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods

Substances

  • Carboxylic Acids
  • Cyclobutanes
  • Radiopharmaceuticals
  • fluciclovine F-18