Arterial Spin Labeling Perfusion Magnetic Resonance Image with Dual Postlabeling Delay: A Correlative Study with Acetazolamide Loading (123)I-Iodoamphetamine Single-Photon Emission Computed Tomography

J Stroke Cerebrovasc Dis. 2016 Jan;25(1):1-6. doi: 10.1016/j.jstrokecerebrovasdis.2015.08.025. Epub 2015 Sep 19.

Abstract

Background: Perfusion magnetic resonance image with arterial spin labeling (ASL) provides a completely noninvasive measurement of cerebral blood flow (CBF). However, arterial transient times can have a marked effect on the ASL signal. For example, a single postlabeling delay (PLD) of 1.5 seconds underestimates the slowly streaming collateral pathways that maintain the cerebrovascular reserve (CVR). To overcome this limitation, we developed a dual PLD method.

Subjects and methods: A dual PLD method of 1.5 and 2.5 seconds was compared with (123)I-iodoamphetamine single-photon emission computed tomography with acetazolamide loading to assess CVR in 10 patients with steno-occlusive cerebrovascular disease.

Results: In 5 cases (Group A), dual PLD-ASL demonstrated low CBF with 1.5-second PLD in the target area, whereas CBF was improved with 2.5-second PLD. In the other 5 cases (Group B), dual PLD-ASL depicted low CBF with 1.5-second PLD, and no improvement in CBF with 2.5-second PLD in the target area was observed. On single-photon emission computed tomography, CVR was maintained in Group A but decreased in Group B.

Conclusions: Although dual PLD methods may not be a completely alternative test for (123)I-iodoamphetamine single-photon emission computed tomography with acetazolamide loading, it is a feasible, simple, noninvasive, and repeatable technique for assessing CVR, even when employed in a routine clinical setting.

Keywords: Arterial spin labeling; IMP SPECT; MR perfusion image; cerebrovascular reserve; postlabeling delay.

Publication types

  • Case Reports
  • Evaluation Study

MeSH terms

  • Acetazolamide / administration & dosage
  • Acetazolamide / pharmacology
  • Aged
  • Aged, 80 and over
  • Carotid Artery, Internal / diagnostic imaging
  • Carotid Artery, Internal / pathology
  • Carotid Stenosis / diagnostic imaging
  • Carotid Stenosis / pathology
  • Cerebral Arteries / diagnostic imaging
  • Cerebral Arteries / physiopathology
  • Cerebrovascular Circulation* / drug effects
  • Cerebrovascular Disorders / diagnostic imaging
  • Cerebrovascular Disorders / pathology*
  • Collateral Circulation
  • Contrast Media
  • Diffusion Magnetic Resonance Imaging / methods
  • Female
  • Humans
  • Infarction, Middle Cerebral Artery / diagnostic imaging
  • Infarction, Middle Cerebral Artery / pathology
  • Intracranial Arteriosclerosis / diagnostic imaging
  • Intracranial Arteriosclerosis / pathology
  • Iofetamine / administration & dosage
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Multimodal Imaging / methods*
  • Neuroimaging / methods*
  • Perfusion Imaging / methods*
  • Retrospective Studies
  • Spin Labels
  • Stroke / prevention & control
  • Time Factors
  • Tomography, Emission-Computed, Single-Photon / methods
  • Vasodilator Agents / administration & dosage
  • Vasodilator Agents / pharmacology

Substances

  • Contrast Media
  • Spin Labels
  • Vasodilator Agents
  • Iofetamine
  • Acetazolamide