Feasibility of Computed Tomography-Guided Methods for Spatial Normalization of Dopamine Transporter Positron Emission Tomography Image

PLoS One. 2015 Jul 6;10(7):e0132585. doi: 10.1371/journal.pone.0132585. eCollection 2015.

Abstract

Background: Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD).

Methods: We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison.

Results: The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P < 0.0001). Putaminal SUVR values were highly effective for discriminating PD patients from controls. However, the PET-guided method excessively overestimated striatal SUVR values in the PD patients by more than 30% in caudate and putamen, and thereby spoiled the linearity between the striatal SUVR values in all subjects and showed lower disease discrimination ability. Two CT-guided methods showed comparable capability with the MR-guided methods in separating PD patients from controls and showed better correlation between putaminal SUVR values and the parkinsonian motor severity than the PET-guided method.

Conclusion: CT-guided spatial normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Cerebellum* / diagnostic imaging
  • Cerebellum* / metabolism
  • Dopamine Plasma Membrane Transport Proteins / metabolism*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Parkinson Disease* / diagnostic imaging
  • Parkinson Disease* / metabolism
  • Positron-Emission Tomography / methods*
  • Radiography
  • Tropanes / administration & dosage*

Substances

  • Dopamine Plasma Membrane Transport Proteins
  • Tropanes
  • 2-carbomethoxy-8-(3-fluoropropyl)-3-(4-iodophenyl)tropane

Grants and funding

This study was supported by a faculty research grant of Yonsei University College of Medicine (grant number 6-2014-0123). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.