Diagnostic accuracy of (18)F-FDG PET/CT compared with that of contrast-enhanced MRI of the breast at 3 T

Eur J Nucl Med Mol Imaging. 2015 Oct;42(11):1656-1665. doi: 10.1007/s00259-015-3099-1. Epub 2015 Jun 30.

Abstract

Purpose: To compare the diagnostic accuracy of prone (18)F-FDG PET/CT with that of contrast-enhanced MRI (CE-MRI) at 3 T in suspicious breast lesions. To evaluate the influence of tumour size on diagnostic accuracy and the use of maximum standardized uptake value (SUVMAX) thresholds to differentiate malignant from benign breast lesions.

Methods: A total of 172 consecutive patients with an imaging abnormality were included in this IRB-approved prospective study. All patients underwent (18)F-FDG PET/CT and CE-MRI of the breast at 3 T in the prone position. Two reader teams independently evaluated the likelihood of malignancy as determined by (18)F-FDG PET/CT and CE-MRI independently. (18)F-FDG PET/CT data were qualitatively evaluated by visual interpretation. Quantitative assessment was performed by calculation of SUVMAX. Sensitivity, specificity, diagnostic accuracy, area under the curve and interreader agreement were calculated for all lesions and for lesions <10 mm. Histopathology was used as the standard of reference.

Results: There were 132 malignant and 40 benign lesions; 23 lesions (13.4%) were <10 mm. Both (18)F-FDG PET/CT and CE-MRI achieved an overall diagnostic accuracy of 93%. There were no significant differences in sensitivity (p = 0.125), specificity (p = 0.344) or diagnostic accuracy (p = 1). For lesions <10 mm, diagnostic accuracy deteriorated to 91% with both (18)F-FDG PET/CT and CE-MRI. Although no significant difference was found for lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than (18)F-FDG PET/CT. Interreader agreement was excellent (κ = 0.85 and κ = 0.92). SUVMAX threshold was not helpful in differentiating benign from malignant lesions.

Conclusion: (18)F-FDG PET/CT and CE-MRI at 3 T showed equal diagnostic accuracies in breast cancer diagnosis. For lesions <10 mm, diagnostic accuracy deteriorated, but was equal for (18)F-FDG PET/CT and CE-MRI at 3 T. For lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than (18)F-FDG PET/CT. Quantitative assessment using an SUVMAX threshold for differentiating benign from malignant lesions was not helpful in breast cancer diagnosis.

Publication types

  • Clinical Trial
  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Breast / diagnostic imaging*
  • Breast Neoplasms / diagnostic imaging
  • Contrast Media*
  • Diagnosis, Differential
  • Female
  • Fluorodeoxyglucose F18*
  • Humans
  • Magnetic Resonance Imaging*
  • Middle Aged
  • Multimodal Imaging
  • Positron-Emission Tomography*
  • ROC Curve
  • Tomography, X-Ray Computed*
  • Young Adult

Substances

  • Contrast Media
  • Fluorodeoxyglucose F18