Modeling pathologic response of esophageal cancer to chemoradiation therapy using spatial-temporal 18F-FDG PET features, clinical parameters, and demographics

Int J Radiat Oncol Biol Phys. 2014 Jan 1;88(1):195-203. doi: 10.1016/j.ijrobp.2013.09.037. Epub 2013 Nov 1.

Abstract

Purpose: To construct predictive models using comprehensive tumor features for the evaluation of tumor response to neoadjuvant chemoradiation therapy (CRT) in patients with esophageal cancer.

Methods and materials: This study included 20 patients who underwent trimodality therapy (CRT+surgery) and underwent 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) both before and after CRT. Four groups of tumor features were examined: (1) conventional PET/CT response measures (eg, standardized uptake value [SUV]max, tumor diameter); (2) clinical parameters (eg, TNM stage, histology) and demographics; (3) spatial-temporal PET features, which characterize tumor SUV intensity distribution, spatial patterns, geometry, and associated changes resulting from CRT; and (4) all features combined. An optimal feature set was identified with recursive feature selection and cross-validations. Support vector machine (SVM) and logistic regression (LR) models were constructed for prediction of pathologic tumor response to CRT, cross-validations being used to avoid model overfitting. Prediction accuracy was assessed by area under the receiver operating characteristic curve (AUC), and precision was evaluated by confidence intervals (CIs) of AUC.

Results: When applied to the 4 groups of tumor features, the LR model achieved AUCs (95% CI) of 0.57 (0.10), 0.73 (0.07), 0.90 (0.06), and 0.90 (0.06). The SVM model achieved AUCs (95% CI) of 0.56 (0.07), 0.60 (0.06), 0.94 (0.02), and 1.00 (no misclassifications). With the use of spatial-temporal PET features combined with conventional PET/CT measures and clinical parameters, the SVM model achieved very high accuracy (AUC 1.00) and precision (no misclassifications)-results that were significantly better than when conventional PET/CT measures or clinical parameters and demographics alone were used. For groups with many tumor features (groups 3 and 4), the SVM model achieved significantly higher accuracy than did the LR model.

Conclusions: The SVM model that used all features including spatial-temporal PET features accurately and precisely predicted pathologic tumor response to CRT in esophageal cancer.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adenocarcinoma / diagnostic imaging
  • Adenocarcinoma / pathology
  • Adenocarcinoma / therapy
  • Carcinoma, Squamous Cell / diagnostic imaging
  • Carcinoma, Squamous Cell / pathology
  • Carcinoma, Squamous Cell / therapy
  • Chemoradiotherapy, Adjuvant / methods*
  • Esophageal Neoplasms / diagnostic imaging*
  • Esophageal Neoplasms / pathology
  • Esophageal Neoplasms / therapy*
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Logistic Models
  • Male
  • Middle Aged
  • Models, Biological*
  • Multimodal Imaging / methods*
  • Positron-Emission Tomography / methods*
  • ROC Curve
  • Radiopharmaceuticals
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed
  • Treatment Outcome
  • Tumor Burden

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18