Can DCE-MRI explain the heterogeneity in radiopeptide uptake imaged by SPECT in a pancreatic neuroendocrine tumor model?

PLoS One. 2013 Oct 8;8(10):e77076. doi: 10.1371/journal.pone.0077076. eCollection 2013.

Abstract

Although efficient delivery and distribution of treatment agents over the whole tumor is essential for successful tumor treatment, the distribution of most of these agents cannot be visualized. However, with single-photon emission computed tomography (SPECT), both delivery and uptake of radiolabeled peptides can be visualized in a neuroendocrine tumor model overexpressing somatostatin receptors. A heterogeneous peptide uptake is often observed in these tumors. We hypothesized that peptide distribution in the tumor is spatially related to tumor perfusion, vessel density and permeability, as imaged and quantified by DCE-MRI in a neuroendocrine tumor model. Four subcutaneous CA20948 tumor-bearing Lewis rats were injected with the somatostatin-analog (111)In-DTPA-Octreotide (50 MBq). SPECT-CT and MRI scans were acquired and MRI was spatially registered to SPECT-CT. DCE-MRI was analyzed using semi-quantitative and quantitative methods. Correlation between SPECT and DCE-MRI was investigated with 1) Spearman's rank correlation coefficient; 2) SPECT uptake values grouped into deciles with corresponding median DCE-MRI parametric values and vice versa; and 3) linear regression analysis for median parameter values in combined datasets. In all tumors, areas with low peptide uptake correlated with low perfusion/density/ /permeability for all DCE-MRI-derived parameters. Combining all datasets, highest linear regression was found between peptide uptake and semi-quantitative parameters (R(2)>0.7). The average correlation coefficient between SPECT and DCE-MRI-derived parameters ranged from 0.52-0.56 (p<0.05) for parameters primarily associated with exchange between blood and extracellular extravascular space. For these parameters a linear relation with peptide uptake was observed. In conclusion, the 'exchange-related' DCE-MRI-derived parameters seemed to predict peptide uptake better than the 'contrast amount- related' parameters. Consequently, fast and efficient diffusion through the vessel wall into tissue is an important factor for peptide delivery. DCE-MRI helps to elucidate the relation between vascular characteristics, peptide delivery and treatment efficacy, and may form a basis to predict targeting efficiency.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Contrast Media / chemistry
  • Contrast Media / pharmacokinetics
  • Indium Radioisotopes* / chemistry
  • Indium Radioisotopes* / pharmacokinetics
  • Magnetic Resonance Imaging / methods
  • Male
  • Neuroendocrine Tumors / diagnosis*
  • Octreotide* / chemistry
  • Octreotide* / pharmacokinetics
  • Pancreas / pathology
  • Pancreatic Neoplasms / diagnosis*
  • Pentetic Acid* / chemistry
  • Pentetic Acid* / pharmacokinetics
  • Rats
  • Rats, Inbred Lew
  • Somatostatin / analogs & derivatives
  • Tomography, Emission-Computed, Single-Photon / methods

Substances

  • Contrast Media
  • Indium Radioisotopes
  • Somatostatin
  • Pentetic Acid
  • Octreotide

Grants and funding

This work was funded by the Dutch Cancer Society – KWF (grant no. 2008-4037) - http://www.kwfkankerbestrijding.nl/Pages/Home.aspx. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.