Combined contrast-enhanced magnetic resonance and diffusion-weighted imaging reading adapted to the "Breast Imaging Reporting and Data System" for multiparametric 3-T imaging of breast lesions

Eur Radiol. 2013 Jul;23(7):1791-802. doi: 10.1007/s00330-013-2771-8. Epub 2013 Mar 16.

Abstract

Objective: To develop and assess a combined reading for contrast-enhanced magnetic resonance (CE-MRI) and diffusion weighted imaging (DWI) adapted to the BI-RADS for multiparametric MRI of the breast at 3 T.

Methods: A total of 247 patients with histopathologically verified breast lesions were included in this IRB-approved prospective study. All patients underwent CE-MR and DWI at 3 T. MRIs were classified according to BI-RADS and assessed for apparent diffusion coefficient (ADC) values. A reading method that adapted ADC thresholds to the assigned BI-RADS classification was developed. Sensitivity, specificity, diagnostic accuracy and the area under the curve were calculated. BI-RADS-adapted reading was compared with previously published reading methods in the same population. Inter- and intra-reader variability was assessed.

Results: Sensitivity of BI-RADS-adapted reading was not different from the high sensitivity of CE-MRI (P = 0.4). BI-RADS-adapted reading maximised specificity (89.4 %), which was significantly higher compared with CE-MRI (P < 0.001). Previous reading methods did not perform as well as the BI-RADS method except for a logistic regression model. BI-RADS-adapted reading was more sensitive in non-mass-like enhancements (NMLE) and was more robust to inter- and intra-reader variability.

Conclusion: Multiparametric 3-T MRI of the breast using a BI-RADS-adapted reading is fast, simple to use and significantly improves the diagnostic accuracy of breast MRI. KEYPOINTS : • Multiparametric breast 3-T MRI with BI-RADS-adapted reading improves diagnostic accuracy. • BI-RADS-adapted reading of CE-MRI and DWI is based on established reporting guidelines. • BI-RADS-adapted reading is fast and easy to use in routine clinical practice. • BI-RADS-adapted reading is robust to intra- and inter-reader variability.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Area Under Curve
  • Breast / pathology
  • Breast Neoplasms / diagnosis*
  • Breast Neoplasms / pathology
  • Contrast Media / pharmacology*
  • Diffusion Magnetic Resonance Imaging / methods*
  • False Positive Reactions
  • Female
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Middle Aged
  • Observer Variation
  • Prospective Studies
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Time Factors
  • Young Adult

Substances

  • Contrast Media