X-ray induced DNA double-strand breaks in coronary CT angiography: comparison of sequential, low-pitch helical and high-pitch helical data acquisition

Eur J Radiol. 2012 Mar;81(3):e357-62. doi: 10.1016/j.ejrad.2011.11.027. Epub 2011 Dec 16.

Abstract

Background: Aim of this study was to compare DNA double-strand breaks (DSBs) in blood lymphocytes of patients undergoing high-pitch helical, low-pitch helical and sequential coronary CT angiography.

Methods and results: 66 patients were examined with various scan protocols and modes (low-pitch helical scan: 100-120 kV, 320-438 mAs/rot, pitch 0.18-0.39, with or without ECG-pulsing, n=35; prospectively ECG-triggered high-pitch helical scan: 100-120 kV, 320-456 mAs/rotation, pitch 3.2-3.4, n=19; prospectively ECG-triggered sequential scan: 100-120 kV, 150-300 mAs or 320-370 mAs/rotation, n=12) either using a 64-slice or 128-slice dual-source CT or a 128-slice single source CT scanner. Blood samples were obtained before and 30 min after CT and DSBs were analyzed in isolated lymphocytes using γ-H2AX immunofluorescence microscopy. A significant increase of DSBs was measurable 30 min after CTA (range 0.01-0.71/cell). CT induced DSBs showed a significant correlation with the estimated effective dose (ρ=0.90, p<0.00001). Both prospectively ECG-triggered sequential (0.10 DSBs/cell, 176 mGy cm, p<0.00001) and high-pitch helical scan protocols (0.03 DSBs/cell, 109 mGy cm, p<0.00001) led to a significant reduction of median DLP and DSB levels compared to low-pitch helical scans (0.34 DSBs/cell, 828 mGy cm). A reduction of the tube voltage resulted in significantly lower whereas additional calcium scoring resulted in elevated DLP and DNA damages (p<0.05 each).

Conclusion: In coronary CTA, data acquisition protocols have a significant influence on the X-ray induced DSB levels. Using γ-H2AX immunofluorescence microscopy different scan modes in different CT generations can be compared concerning their biological impact.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Cardiac-Gated Imaging Techniques / adverse effects
  • Cardiac-Gated Imaging Techniques / methods*
  • Contrast Media
  • Coronary Angiography / adverse effects
  • Coronary Angiography / methods*
  • Coronary Disease / diagnostic imaging*
  • DNA Breaks, Double-Stranded / radiation effects*
  • Female
  • Humans
  • Lymphocytes / radiation effects*
  • Male
  • Microscopy, Fluorescence
  • Middle Aged
  • Radiation Dosage
  • Statistics, Nonparametric
  • Tomography, Spiral Computed / adverse effects
  • Tomography, Spiral Computed / methods*

Substances

  • Contrast Media