Cost comparison of 111In-DTPA-octreotide scintigraphy and 68Ga-DOTATOC PET/CT for staging enteropancreatic neuroendocrine tumours

Eur J Nucl Med Mol Imaging. 2012 Jan;39(1):72-82. doi: 10.1007/s00259-011-1935-5. Epub 2011 Sep 17.

Abstract

Purpose: Although somatostatin receptor positron emission tomography (PET)/CT is gaining increasing popularity and has shown its diagnostic superiority in several studies, (111)In-diethylenetriaminepentaacetic acid (DTPA)-octreotide is still the current standard for diagnosis of neuroendocrine tumours (NET). The aim of this study was to compare the costs for the two diagnostic tests and the respective consequential costs.

Methods: From January 2009 to July 2009, 51 consecutive patients with enteropancreatic NET who underwent contrast-enhanced (68)Ga-DOTATOC PET/CT (n = 29) or (111)In-DTPA-octreotide (mean 3 whole-body scans plus 1.6 low-dose single photon emission computed tomography/CT; n = 22) were included. For cost analysis, direct costs (equipment) and variable costs (material, labour) per examination were calculated. Additionally required CT and/or MRI examinations within the staging process were assessed as consequential costs. An additional deterministic sensitivity analysis was performed.

Results: A (68)Ga-DOTATOC PET/CT examination yielded total costs (equipment, personnel and material costs) of 548 euro. On the other hand, an (111)In-DTPA-octreotide examination resulted in 827 euro total costs. Costs for equipment and material had a share of 460 euro/720 euro for (68)Ga-DOTATOC/(111)In-DTPA-octreotide and labour costs of 89 euro/106 euro. With (68)Ga-DOTATOC additional MRI had to be performed in 7% of the patients resulting in a mean of 20 euro for supplementary imaging per patient; 82% of patients with (111)In-DTPA-octreotide needed additional MRI and/or CT resulting in mean additional costs of 161 euro per patient.

Conclusion: (68)Ga-DOTATOC PET/CT was considerably cheaper than (111)In-DTPA-octreotide with respect to both material and personnel costs. Furthermore, by using (68)Ga-DOTATOC PET/CT considerably fewer additional examinations were needed reducing the consequential costs significantly.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Cost-Benefit Analysis
  • Female
  • Humans
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Multimodal Imaging / economics*
  • Neoplasm Staging
  • Neuroendocrine Tumors / diagnostic imaging*
  • Neuroendocrine Tumors / pathology*
  • Octreotide / analogs & derivatives*
  • Octreotide / economics
  • Organometallic Compounds* / economics
  • Pancreatic Neoplasms / diagnostic imaging*
  • Pancreatic Neoplasms / pathology*
  • Pentetic Acid / analogs & derivatives*
  • Pentetic Acid / economics
  • Positron-Emission Tomography*
  • Tomography, X-Ray Computed*

Substances

  • 111In-octreotide, DTPA(0)-
  • Ga(III)-DOTATOC
  • Organometallic Compounds
  • Pentetic Acid
  • Octreotide