A meta-analysis of preoperative localization techniques for patients with primary hyperparathyroidism

Ann Surg Oncol. 2012 Feb;19(2):577-83. doi: 10.1245/s10434-011-1870-5. Epub 2011 Jun 28.

Abstract

Background: Reported accuracy of preoperative localization imaging for primary hyperparathyroidism (pHPT) varies. The purpose of this study is to determine the accuracy of ultrasound, sestamibi-single photon emission computed tomography (SPECT), and four-dimensional computed tomography (4D-CT) as preoperative localization strategies.

Methods: A meta-analysis was performed of studies investigating the accuracy of ultrasound, sestamibi-SPECT, and 4D-CT for preoperative localization in pHPT. Electronic databases were systematically searched, and two independent reviewers reviewed results using specific criteria. Study quality was assessed using a validated measure for diagnostic imaging studies. Study heterogeneity and pooled results were calculated.

Results: 43 studies met criteria for inclusion, and data were available for extraction in 19 ultrasound, 9 sestamibi-SPECT, and 4 4D-CT studies. Ultrasound had pooled sensitivity and positive predictive value (PPV) of 76.1% (95% CI 70.4-81.4%) and 93.2% (90.7-95.3%), respectively. Sestamibi-SPECT had pooled sensitivity and PPV of 78.9% (64-90.6%) and 90.7% (83.5-96.0%), respectively. Only two 4D-CT studies investigated patients undergoing initial parathyroidectomy. Results suggested sensitivity and PPV of 89.4% and 93.5%, respectively.

Conclusions: Ultrasound and sestamibi-SPECT are similar in ability to preoperatively localize abnormal parathyroid glands in pHPT. Accuracy may be improved with 4D-CT; however, further investigation is required. Choice of preoperative imaging strategy depends on numerous patient, institutional, and economic factors of which the surgeon must be aware.

Publication types

  • Meta-Analysis

MeSH terms

  • Four-Dimensional Computed Tomography*
  • Humans
  • Hyperparathyroidism, Primary / diagnosis*
  • Hyperparathyroidism, Primary / surgery*
  • Predictive Value of Tests
  • Preoperative Care*
  • Radiopharmaceuticals*
  • Technetium Tc 99m Sestamibi*
  • Tomography, Emission-Computed, Single-Photon*

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Sestamibi