Impact of [11C]methionine positron emission tomography for target definition of glioblastoma multiforme in radiation therapy planning

Int J Radiat Oncol Biol Phys. 2012 Jan 1;82(1):83-9. doi: 10.1016/j.ijrobp.2010.09.020. Epub 2010 Nov 20.

Abstract

Purpose: The purpose of this work was to define the optimal margins for gadolinium-enhanced T(1)-weighted magnetic resonance imaging (Gd-MRI) and T(2)-weighted MRI (T(2)-MRI) for delineating target volumes in planning radiation therapy for postoperative patients with newly diagnosed glioblastoma multiforme (GBM) by comparison to carbon-11-labeled methionine positron emission tomography ([(11)C]MET-PET) findings.

Methods and materials: Computed tomography (CT), MRI, and [(11)C]MET-PET were separately performed for radiation therapy planning for 32 patients newly diagnosed with GBM within 2 weeks after undergoing surgery. The extent of Gd-MRI (Gd-enhanced clinical target volume [CTV-Gd]) uptake and that of T(2)-MRI of the CTV (CTV-T(2)) were compared with the extent of [(11)C]MET-PET (CTV--[(11)C]MET-PET) uptake by using CT--MRI or CT--[(11)C]MET-PET fusion imaging. We defined CTV-Gd (x mm) and CTV-T(2) (x mm) as the x-mm margins (where x = 0, 2, 5, 10, and 20 mm) outside the CTV-Gd and the CTV-T(2), respectively. We evaluated the relationship between CTV-Gd (x mm) and CTV-- [(11)C]MET-PET and the relationship between CTV-T(2) (x mm) and CTV-- [(11)C]MET-PET.

Results: The sensitivity of CTV-Gd (20 mm) (86.4%) was significantly higher than that of the other CTV-Gd. The sensitivity of CTV-T(2) (20 mm) (96.4%) was significantly higher than that of the other CTV-T(2) (x = 0, 2, 5, 10 mm). The highest sensitivity and lowest specificity was found with CTV-T(2) (x = 20 mm).

Conclusions: It is necessary to use a margin of at least 2 cm for CTV-T(2) for the initial target planning of radiation therapy. However, there is a limit to this setting in defining the optimal margin for Gd-MRI and T(2)-MRI for the precise delineation of target volumes in radiation therapy planning for postoperative patients with GBM.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Brain Neoplasms / diagnostic imaging*
  • Brain Neoplasms / pathology
  • Brain Neoplasms / radiotherapy
  • Contrast Media
  • Female
  • Gadolinium
  • Glioblastoma / diagnostic imaging*
  • Glioblastoma / pathology
  • Glioblastoma / radiotherapy
  • Humans
  • Magnetic Resonance Imaging / methods
  • Male
  • Methionine*
  • Middle Aged
  • Positron-Emission Tomography / methods
  • Radiopharmaceuticals*
  • Radiotherapy Planning, Computer-Assisted / methods*
  • Sensitivity and Specificity
  • Tomography, Spiral Computed / methods
  • Tumor Burden*
  • Young Adult

Substances

  • Contrast Media
  • Radiopharmaceuticals
  • carbon-11 methionine
  • Methionine
  • Gadolinium