PET imaging of HER1-expressing xenografts in mice with 86Y-CHX-A''-DTPA-cetuximab

Eur J Nucl Med Mol Imaging. 2010 Jul;37(7):1368-76. doi: 10.1007/s00259-009-1370-z. Epub 2010 Feb 13.

Abstract

Purpose: Cetuximab is a recombinant, human/mouse chimeric IgG(1) monoclonal antibody that binds to the epidermal growth factor receptor (EGFR/HER1). Cetuximab is approved for the treatment of patients with HER1-expressing metastatic colorectal cancer. Limitations in currently reported radiolabeled cetuximab for PET applications prompted the development of (86)Y-CHX-A''-DTPA-cetuximab as an alternative for imaging HER1-expressing cancer. (86)Y-CHX-A''-DTPA-cetuximab can also serve as a surrogate marker for (90)Y therapy.

Methods: Bifunctional chelate, CHX-A''-DTPA was conjugated to cetuximab and radiolabeled with (86)Y. In vitro immunoreactivity was assessed in HER1-expressing A431 cells. In vivo biodistribution, PET imaging and noncompartmental pharmacokinetics were performed in mice bearing HER1-expressing human colorectal (LS-174T and HT29), prostate (PC-3 and DU145), ovarian (SKOV3) and pancreatic (SHAW) tumor xenografts. Receptor blockage was demonstrated by coinjection of either 0.1 or 0.2 mg cetuximab.

Results: (86)Y-CHX-A''-DTPA-cetuximab was routinely prepared with a specific activity of 1.5-2 GBq/mg and in vitro cell-binding in the range 65-75%. Biodistribution and PET imaging studies demonstrated high HER1-specific tumor uptake of the radiotracer and clearance from nonspecific organs. In LS-174T tumor-bearing mice injected with (86)Y-CHX-A''-DTPA-cetuximab alone, (86)Y-CHX-A''-DTPA-cetuximab plus 0.1 mg cetuximab or 0.2 mg cetuximab, the tumor uptake values at 3 days were 29.3 +/- 4.2, 10.4 +/- 0.5 and 6.4 +/- 0.3%ID/g, respectively, demonstrating dose-dependent blockage of the target. Tumors were clearly visualized 1 day after injecting 3.8-4.0 MBq (86)Y-CHX-A''-DTPA-cetuximab. Quantitative PET revealed the highest tumor uptake in LS-174T (29.55 +/- 2.67%ID/cm(3)) and the lowest tumor uptake in PC-3 (15.92 +/- 1.55%ID/cm(3)) xenografts at 3 days after injection. Tumor uptake values quantified by PET were closely correlated (r (2) = 0.9, n = 18) with values determined by biodistribution studies.

Conclusion: This study demonstrated the feasibility of preparation of high specific activity (86)Y-CHX-A''-DTPA-cetuximab and its application for quantitative noninvasive PET imaging of HER1-expressing tumors. (86)Y-CHX-A''-DTPA-cetuximab offers an attractive alternative to previously labeled cetuximab for PET and further investigation for clinical translation is warranted.

Publication types

  • Research Support, N.I.H., Intramural

MeSH terms

  • Animals
  • Antibodies, Monoclonal / chemistry*
  • Antibodies, Monoclonal / immunology
  • Antibodies, Monoclonal / pharmacokinetics
  • Antibodies, Monoclonal, Humanized
  • Cell Line, Tumor
  • Cell Transformation, Neoplastic*
  • Cetuximab
  • ErbB Receptors / immunology
  • ErbB Receptors / metabolism*
  • Female
  • Gene Expression Regulation, Neoplastic
  • Humans
  • Isothiocyanates / chemistry*
  • Mice
  • Neoplasms / diagnostic imaging
  • Neoplasms / genetics
  • Neoplasms / pathology
  • Pentetic Acid / analogs & derivatives*
  • Pentetic Acid / chemistry
  • Positron-Emission Tomography / methods*
  • Radiochemistry
  • Yttrium Radioisotopes

Substances

  • Antibodies, Monoclonal
  • Antibodies, Monoclonal, Humanized
  • Isothiocyanates
  • Yttrium Radioisotopes
  • N-(2-amino-3-(4-isothiocyanatophenyl)propyl)cyclohexane-1,2-diamine-N,N',N',N'',N''-pentaacetic acid
  • Pentetic Acid
  • ErbB Receptors
  • Cetuximab