Dose-response effect of Gelofusine on renal uptake and retention of radiolabelled octreotate in rats with CA20948 tumours

Eur J Nucl Med Mol Imaging. 2009 Dec;36(12):1968-76. doi: 10.1007/s00259-009-1196-8.

Abstract

Purpose: Peptide receptor radionuclide therapy using β-emitting radiolabelled somatostatin analogues like DOTA,Tyr3-octreotate shows beneficial results in patients suffering from somatostatin receptor overexpressing tumours. However, after high-dose therapy partial renal reabsorption of radiopeptides may lead to nephrotoxicity. Co-infusion of lysine/arginine lowers renal retention of these radiopeptides without affecting tumour uptake. Recently co-administration of Gelofusine has been described to have a comparable kidney-protecting effect in rats. In the present study optimal dosing of Gelofusine co-administration was studied in tumour-bearing rats.

Methods: Doses of 40, 80, 120 or 160 mg/kg Gelofusine were co-injected with 15 µg DOTA,Tyr3-octreotate, labelled with 3 MBq 111In for biodistribution (24 h post-injection, n = 4 per group) and with 60 MBq 111In for microSPECT imaging experiments at 3, 24 and 48 h post-injection. An additional group of rats received 80 mg/kg Gelofusine plus 400 mg/kg lysine co-injection. Biodistribution studies were performed both in older (475 g) and younger (300 g) rats, the latter bearing CA20948 tumours.

Results: Co-injection of 40 mg/kg Gelofusine resulted in 40-50% reduction of renal uptake and retention of 111In-DOTA,Tyr3-octreotate, whereas higher doses further increased the reduction to 50-60% in both groups of rats. Combining Gelofusine and lysine caused 70% reduction of renal uptake. The uptake of radiolabelled octreotate both in somatostatin receptor-expressing normal tissues and tumours was not affected by Gelofusine co-injection.

Conclusion: In rats co-injection of 80 mg/kg Gelofusine resulted in maximum reduction of renal retention of 111In-DOTA,Tyr3-octreotate, which was further improved when combined with lysine. Tumour uptake of radiolabelled octreotate was not affected, resulting in an increased tumour to kidney ratio.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Biological Transport / drug effects
  • Cell Line, Tumor
  • Cell Transformation, Neoplastic
  • Dose-Response Relationship, Drug
  • Gene Expression Regulation, Neoplastic
  • Isotope Labeling
  • Kidney / drug effects*
  • Kidney / metabolism*
  • Male
  • Pancreatic Neoplasms / diagnostic imaging
  • Pancreatic Neoplasms / metabolism
  • Pancreatic Neoplasms / pathology*
  • Peptides, Cyclic / metabolism*
  • Peptides, Cyclic / pharmacokinetics
  • Polygeline / pharmacology*
  • Rats
  • Receptors, Somatostatin / metabolism
  • Tissue Distribution / drug effects
  • Tomography, Emission-Computed, Single-Photon
  • Tomography, X-Ray Computed

Substances

  • Peptides, Cyclic
  • Receptors, Somatostatin
  • octreotate, Tyr(3)-
  • Polygeline