Autoradiographic and small-animal PET comparisons between (18)F-FMISO, (18)F-FDG, (18)F-FLT and the hypoxic selective (64)Cu-ATSM in a rodent model of cancer

Nucl Med Biol. 2008 Aug;35(6):713-20. doi: 10.1016/j.nucmedbio.2008.06.001.

Abstract

Introduction: Copper(II)-diacetyl-bis(N(4)-methylthiosemicarbazone), or Cu-ATSM, a hypoxia imaging agent, has been shown to be predictive of response to traditional cancer therapies in patients with a wide range of tumors. It is known that the environment of the tumor results in a myriad of physiological consequences, including hypoxia, alterations in metabolism and proliferation. In an effort to better characterize the relationships between Cu-ATSM and other prominent radiopharmaceuticals, this current study was undertaken to compare the regional distribution of (64)Cu-ATSM with [(18)F]fluoromisonidazole ((18)F-FMISO), [(18)F]fluoro-2-deoxy-d-glucose ((18)F-FDG) and [(18)F]fluorothymidine ((18)F-FLT) in 9L tumors.

Methods: Taking advantage of the different half-life of (18)F (t(1/2)=110 min) in comparison to (64)Cu (t(1/2)=12.7 h), we undertook a dual-tracer autoradiography study in 9L tumors. Four groups were examined: (a) (18)F-FMISO, 2 h postinjection (p.i.) and (64)Cu-ATSM, 10 min p.i.; (b) (18)F-FMISO, 2 h p.i. and (64)Cu-ATSM, 24 h p.i.; (c) (18)F-FDG, 1 h p.i. and (64)Cu-ATSM, 10 min p.i.; and (d) (18)F-FLT, 1 h p.i. and (64)Cu-ATSM, 10 min p.i. Small-animal PET imaging was performed in 9L tumor-bearing rats with imaging on concurrent days comparing (64)Cu-ATSM with (18)F-FMISO and (18)F-FLT.

Results: It was shown that the regional distribution of (18)F-FMISO and (64)Cu-ATSM showed an excellent correlation when the (64)Cu-ATSM had been allowed to distribute for either 10 min (R(2)=.84) or 24 h (R(2)=.86). The regional comparisons between (64)Cu-ATSM (10 min) and (18)F-FDG (1 h) resulted in a very poor correlation (R(2)=.08) between the regional uptake of the two agents. The comparison between (18)F-FLT and (64)Cu-ATSM showed a strong relationship (R(2)=.83) between the two tracers. The small-animal PET images for the distribution comparisons between (64)Cu-ATSM and (18)F-FMISO and (18)F-FLT were in agreement with the data generated from the autoradiography studies.

Conclusions: The data show that it is important to remember that a number of different metabolic situations can exist when considering the relationship between regions of high glucose uptake, proliferation and hypoxia.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Animals
  • Autoradiography*
  • Cell Line, Tumor
  • Coordination Complexes
  • Copper Radioisotopes / pharmacokinetics*
  • Dideoxynucleosides / pharmacokinetics*
  • Disease Models, Animal
  • Female
  • Fluorodeoxyglucose F18 / pharmacokinetics*
  • Gliosarcoma / diagnostic imaging
  • Gliosarcoma / metabolism*
  • Humans
  • Metabolic Clearance Rate
  • Misonidazole / analogs & derivatives*
  • Misonidazole / pharmacokinetics
  • Organometallic Compounds / pharmacokinetics*
  • Positron-Emission Tomography / veterinary*
  • Radiopharmaceuticals / pharmacokinetics
  • Rats
  • Rats, Inbred F344
  • Thiosemicarbazones / pharmacokinetics*
  • Tissue Distribution

Substances

  • Coordination Complexes
  • Copper Radioisotopes
  • Dideoxynucleosides
  • Organometallic Compounds
  • Radiopharmaceuticals
  • Thiosemicarbazones
  • copper (II) diacetyl-di(N(4)-methylthiosemicarbazone)
  • fluoromisonidazole
  • Fluorodeoxyglucose F18
  • Misonidazole
  • alovudine