CT and PET: early prognostic indicators of response to imatinib mesylate in patients with gastrointestinal stromal tumor

AJR Am J Roentgenol. 2007 Dec;189(6):W324-30. doi: 10.2214/AJR.07.2496.

Abstract

Objective: We report results from a pilot study aimed at optimizing the use of CT bidimensional measurements and 18F-FDG PET maximum standardized uptake values (SUVs-(max)) for determining response to prolonged imatinib mesylate treatment in patients with advanced gastrointestinal stromal tumors (GISTs).

Subjects and methods: Sixty-three patients enrolled in a multicenter trial evaluating imatinib mesylate therapy for advanced GIST underwent FDG PET at baseline and 1 month after initiation of treatment. Of these 63 patients, 58 underwent concomitant CT. Time-to-treatment failure (TTF) was used as the outcome measure. Patients were followed up over a range of 23.7 to 37 months (median, 31.7 months). The predictive power of change in CT bidimensional measurements, change in PET SUVmax, and PET SUVmax at 1 month after initiation of treatment were determined, optimized, and compared. The effectiveness of combining metrics was also evaluated.

Results: Both a threshold PET SUVmax value of 2.5 at 1 month (p = 0.04) and the European Organization for Research and Treatment of Cancer (EORTC) criteria for partial response on FDG PET (25% reduction in PET SUVmax) at 1 month (p = 0.004) were predictive of prolonged treatment success. The Southwest Oncology Group (SWOG) criteria for partial response ((3) 50% reduction in CT bidimensional measurements) at 1 month were not predictive (p = 0.55) of TTF. Optimizing metrics improved results performance. An optimized PET SUVmax threshold of 3.4 (p = 0.00002), a reduction in the SUVmax of 40% (p = 0.002), and an optimized CT bidimensional measurement threshold--that is, no growth from baseline to 1 month (p = 0.00005)--outperformed the existing standards (i.e., EORTC and SWOG criteria). Combinations of metrics did not improve performance.

Conclusion: The two best metrics were the optimized PET SUVmax threshold of 3.4 at 1 month (p = 0.00002) and the optimized CT bidimensional measurement threshold (no growth from baseline to 1 month, p = 0.00005) in this patient group.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Antineoplastic Agents / therapeutic use
  • Benzamides
  • Female
  • Fluorodeoxyglucose F18*
  • Gastrointestinal Stromal Tumors / diagnosis*
  • Gastrointestinal Stromal Tumors / drug therapy*
  • Humans
  • Imatinib Mesylate
  • Male
  • Pilot Projects
  • Piperazines / therapeutic use*
  • Positron-Emission Tomography / methods*
  • Prognosis
  • Pyrimidines / therapeutic use*
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*
  • Treatment Outcome
  • United States

Substances

  • Antineoplastic Agents
  • Benzamides
  • Piperazines
  • Pyrimidines
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18
  • Imatinib Mesylate