Real-time intraoperative ureteral guidance using invisible near-infrared fluorescence

J Urol. 2007 Nov;178(5):2197-202. doi: 10.1016/j.juro.2007.06.049. Epub 2007 Sep 17.

Abstract

Purpose: Invisible near-infrared light is safe and it penetrates relatively deeply through tissue and blood without altering the surgical field. Our hypothesis was that near-infrared fluorescence imaging would enable visualization of the ureteral anatomy and flow intraoperatively and in real time.

Materials and methods: CW800-CA (LI-COR, Lincoln, Nebraska), the carboxylic acid form of near-infrared fluorophore IRDye 800CW, was injected intravenously, and its renal clearance kinetics and imaging performance were quantified in 350 gm rats and 35 kg pigs. High performance liquid chromatography and electrospray time-of-flight mass spectrometry were used to characterize CW800-CA metabolism in urine. The clinically available near-infrared fluorophore indocyanine green was also used via retrograde injection into the ureter. Using the 2 near-infrared fluorophores the ureters were imaged under the conditions of steady state, intraluminal foreign bodies and injury.

Results: In rat models the highest signal-to-background ratio for visualization occurred after intravenous injection of 7.5 microg/kg CW800-CA with values of 4.0 or greater and 2.3 or greater at 10 and 30 minutes, respectively. In pig models 7.5 microg/kg CW800-CA clearly visualized the normal ureter and intraluminal foreign bodies as small as 2.5 mm in diameter. Retrograde injection of 10 microM indocyanine green also permitted the detection of normal ureter and pinpointed urine leakage caused by injury. Electrospray time-of-flight mass spectrometry, and absorbance and fluorescence spectral analysis confirmed that the fluorescent material in urine was chemically identical to CW800-CA.

Conclusions: A convenient intravenous injection of CW800-CA or direct injection of indocyanine green permits high sensitivity visualization of the ureters under steady state and abnormal conditions using invisible light.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Animals
  • Chromatography, High Pressure Liquid
  • Coloring Agents
  • Disease Models, Animal
  • Female
  • Foreign Bodies / pathology
  • Foreign Bodies / surgery*
  • Indocyanine Green
  • Male
  • Monitoring, Intraoperative / methods*
  • Rats
  • Rats, Sprague-Dawley
  • Reproducibility of Results
  • Spectrometry, Fluorescence / methods
  • Spectroscopy, Near-Infrared / methods*
  • Swine
  • Ureter / injuries*
  • Ureter / pathology

Substances

  • Coloring Agents
  • Indocyanine Green