Global and regional evaluation of systolic and diastolic left ventricular temporal parameters using a novel program for ECG-gated myocardial perfusion SPECT--validation by comparison with gated equilibrium radionuclide angiography and speckle-tracking radial strain from echocardiography

Ann Nucl Med. 2007 Feb;21(2):115-21. doi: 10.1007/BF03033989.

Abstract

Background: A newly developed program, named cardioGRAF, enabled the evaluation of left ventricular (LV) systolic and diastolic temporal parameters for the estimation of heart failure using ECG-gated myocardial perfusion SPECT (GMPS).

Objective: The feasibility of those global (g-) and regional (r-) parameters was validated to compare with gated equilibrium radionuclide angiography (ERNA) and speckle-tracking radial strain (STS) from echocardiography.

Methods: Thirty-three patients were studied using GMPS and ERNA (n=11) or GMPS and STS (n=22). The following g- or r-parameters obtained by cardioGRAF and ERNA or STS were compared: time to end systole (TES), time from end systole to peak filling rate (TPF1), time from 0 to peak filling rate (TPF2), time to peak radial strain (TPS), time from peak strain to peak negative strain rate (TP-SR1), and time from 0 to peak negative strain rate (TP-SR2).

Results: All g-parameters were successfully obtained by cardioGRAF and ERNA. The results demonstrated good correlations (g-TES: r = 0.79, p < 0.005; g-TPF1: r = 0.75, p < 0.02; TPF2: r = 0.83, p < 0.005). The differences were 11.9 +/- 31.8 ms in g-TES, 19.9 +/- 65.4 ms in g-TPF1, and 37.7 +/- 67.4 ms in g-TPF2. All r-parameters were successfully obtained by cardioGRAF. Eight patients and 12 segments were excluded because of the inadequate quality of routine echocardiography for STS analysis. However, r-parameters obtained by cardioGRAF were significantly correlated with those of STS (r-TES and r-TPS: r = 0.61, p = 1 x 10(-8); r-TPF1 and r-TP-SR1: r = 0.69, p = 3 x 10(-11); r-TPF2 and r-TP-SR2: r = 0.76, p = 2 x 10(-15)). The differences were 22.1 +/- 38.2 ms between r-TES and r-TPS, 7.0 +/- 123.4 ms between r-TPF1 and r-TP-SR1, and 38.1 +/- 111.5 ms between r-TPF2 and r-TP-SR2.

Conclusion: The feasibility of evaluating systolic and diastolic temporal parameters by a new program was validated. This program has the potential to evaluate both diastolic and systolic heterogeneous wall motions which express dyssynchrony in heart failure.

Publication types

  • Comparative Study
  • Evaluation Study
  • Validation Study

MeSH terms

  • Aged
  • Echocardiography / methods
  • Electrocardiography / methods
  • Female
  • Gated Blood-Pool Imaging / methods*
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Software Validation
  • Software*
  • Stroke Volume*
  • Tomography, Emission-Computed, Single-Photon / methods*
  • Ventricular Dysfunction, Left / diagnostic imaging*