Evaluation of therapy for lymphoma

Semin Nucl Med. 2005 Jul;35(3):186-96. doi: 10.1053/j.semnuclmed.2005.02.004.

Abstract

Positron emission tomography (PET) using (18)F-fluorodeoxyglucose ((18)F-FDG) is the best noninvasive imaging technique for to assess response in patients suffering from lymphoma. Early response evaluation ("interim PET") after one, a few cycles, or at midtreatment can predict response, progression-free survival, and overall survival. We calculated from data of 7 studies an overall sensitivity to predict treatment failure of 79%, a specificity of 92%, a positive predictive value (PPV) of 90%, a negative predictive value (NPV) of 81%, and an accuracy of 85%. Although it is not yet indicated to change patient management based on residual (18)F-FDG uptake on interim scan in chemotherapy-sensitive patients, prospective studies evaluating the role of an interim PET in patient management clearly are warranted. (18)F-FDG PET also has an important prognostic role in relapsing patients after reinduction chemotherapy before high-dose chemotherapy (HCT) followed by autologous stem cell transplantation (ASCT). However, all chemotherapy-sensitive patients remain candidates for HCT followed by ASCT, even if (18)F-FDG PET showed residual (18)F-FDG uptake. We calculated from data of 3 studies an overestimated risk of relapse in 16% of all PET-positive patients. Some patients with residual (18)F-FDG uptake will have a good outcome after HCT followed by ASCT. (18)F-FDG PET is the imaging technique of choice for end-of-treatment evaluation. However, (18)F-FDG is not specific for tumoral tissue. Active inflammatory lesions and infectious processes can be falsely interpreted as malignant residual cells. However, a negative (18)F-FDG PET cannot exclude minimal residual disease. Consequently, it is always indicated to correlate PET findings with clinical data, other imaging modalities, and/or a biopsy. We calculated, from data of 17 studies in end-of-treatment evaluation, a sensitivity of 76%, a specificity of 94%, a PPV of 82%, a NPV 92%, and an accuracy of 89%.

Publication types

  • Review

MeSH terms

  • Antineoplastic Agents / therapeutic use*
  • Clinical Trials as Topic
  • Fluorodeoxyglucose F18*
  • Humans
  • Lymphoma / diagnostic imaging*
  • Lymphoma / therapy*
  • Positron-Emission Tomography / methods*
  • Practice Guidelines as Topic
  • Practice Patterns, Physicians'
  • Prognosis
  • Radioimmunotherapy / methods*
  • Radiopharmaceuticals
  • Treatment Outcome

Substances

  • Antineoplastic Agents
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18