Imaging in situ breast carcinoma (with or without an invasive component) with technetium-99m pentavalent dimercaptosuccinic acid and technetium-99m 2-methoxy isobutyl isonitrile scintimammography

Breast Cancer Res. 2005;7(1):R33-45. doi: 10.1186/bcr948. Epub 2004 Nov 8.

Abstract

Introduction: The aim of the study was to retrospectively define specific features of the technetium-99m pentavalent dimercaptosuccinic acid (99mTc-(V)DMSA) and technetium-99m 2-methoxy isobutyl isonitrile (99mTc-Sestamibi [99mTc-MIBI]) distribution in ductal breast carcinoma in situ and lobular breast carcinoma in situ (DCIS/LCIS), in relation to mammographic, histological and immunohistochemical parameters.

Materials and methods: One hundred and two patients with suspicious palpation or mammographic findings were submitted preoperatively to scintimammography (a total of 72 patients with 99mTc-(V)DMSA and a total of 75 patients with 99mTc-Sestamibi, 45 patients receiving both radiotracers). Images were acquired at 10 min and 60 min, and were evaluated for a pattern of diffuse radiotracer accumulation. The tumor-to-background ratios were correlated (T-pair test) with mammographic, histological and immunohistochemical characteristics.

Results: Histology confirmed malignancy in 46/102 patients: 20/46 patients had DCIS/LCIS, with or without coexistent invasive lesions, and 26/46 patients had isolated invasive carcinomas. Diffuse 99mTc-(V)DMSA accumulation was noticed in 18/19 cases and 99mTc-Sestamibi in 6/13 DCIS/LCIS cases. Epithelial hyperplasia demonstrated a similar accumulation pattern. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value for each tracer were calculated. Solely for 99mTc-(V)DMSA, the tumor-to-background ratio was significantly higher at 60 min than at 10 min and the diffuse uptake was significantly associated with suspicious microcalcifications, with the cell proliferation index > or = 40% and with c-erbB-2 > or = 10%.

Conclusion: 99mTc-(V)DMSA showed high sensitivity and 99mTc-Sestamibi showed high specificity in detecting in situ breast carcinoma (99mTc-(V)DMSA especially in cases with increased cell proliferation), and these radiotracers could provide clinicians with preoperative information not always obtainable by mammography.

Publication types

  • Clinical Trial

MeSH terms

  • Aged
  • Breast Neoplasms / diagnostic imaging*
  • Carcinoma in Situ / diagnostic imaging*
  • Carcinoma, Intraductal, Noninfiltrating / diagnostic imaging*
  • Carcinoma, Lobular / diagnostic imaging*
  • Female
  • Humans
  • Immunohistochemistry
  • Mammography / methods*
  • Middle Aged
  • Radionuclide Imaging
  • Sensitivity and Specificity
  • Technetium Tc 99m Dimercaptosuccinic Acid
  • Technetium Tc 99m Sestamibi

Substances

  • Technetium Tc 99m Dimercaptosuccinic Acid
  • Technetium Tc 99m Sestamibi