Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study

Eur J Nucl Med Mol Imaging. 2003 Nov;30(11):1510-9. doi: 10.1007/s00259-003-1246-6. Epub 2003 Sep 23.

Abstract

Iterative reconstruction algorithms, such as the ordered subsets expectation maximisation (OS-EM), are a promising alternative to filtered backprojection (FBP). The aims of this study were first to optimise the OS-EM algorithm in terms of iteration number and to study the usefulness of post-filtering, and second to compare OS-EM and FBP for image reconstruction on a fluorine-18 fluorodeoxyglucose ((18)F-FDG) dual-head camera (DHC). These two goals were addressed using phantom acquisitions. The performances of these algorithms were also studied in patient acquisitions performed on a DHC and a PET on the same day. Phantom experiments were performed on a DHC using a Jaszczak phantom containing six spheres filled with (18)F-FDG, two background levels (0.95, 6.80 kBq/ml) and three object contrasts (5.9, 3.7, 2.7). The reconstruction algorithms were FBP with a Gaussian filter (FWHM 0.5-2 pixel width) and OS-EM using 8-128 equivalent iterations (equivalent to the ML-EM algorithm) with and without Gaussian post-filtering [OS-EM (iterations, pixel width)]. Contrast recovery coefficient (CRC) and noise characteristics were assessed. Twenty-two patients (21 male, one female; age 55+/-15 years) with lung cancer underwent, on the same day, PET (1 h post injection of 37 MBq/kg (18)F-FDG) and DHC acquisitions (3 h post injection). DHC data were reconstructed using six methods: FBP (1), OS-EM (16), (40), (40,1), (64) and (64,1). These sets were evaluated by two observers and compared to PET reconstructed with OS-EM (16). The number of detected lesions and the visual quality were assessed. A marked improvement in CRC was observed with OS-EM as compared with FBP when more than 24 iterations were used. The CRC increased markedly from 8 to 40 iterations and then reached a plateau. The noise was stable until 40 iterations and then increased. The best compromise was obtained for OS-EM (32) and OS-EM (40,1). For the patient study, OS-EM provided images of better visual quality, but with no significant difference in detection sensitivity. OS-EM was superior to FBP in terms of contrast recovery and noise level. The optimal compromise between contrast recovery and noise was obtained for OS-EM (32) and (40,1) on the phantom study. The clinical study showed that OS-EM yielded images of better visual quality but with no improvement in terms of detection of lung cancer.

Publication types

  • Clinical Trial
  • Comparative Study
  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Algorithms*
  • Carcinoma, Non-Small-Cell Lung / diagnostic imaging*
  • Carcinoma, Non-Small-Cell Lung / pathology
  • Female
  • Fluorodeoxyglucose F18*
  • Gamma Cameras
  • Humans
  • Image Enhancement / methods*
  • Image Interpretation, Computer-Assisted / methods*
  • Lung Neoplasms / diagnostic imaging*
  • Lung Neoplasms / pathology
  • Male
  • Middle Aged
  • Phantoms, Imaging
  • Quality Control
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Single-Blind Method
  • Tomography, Emission-Computed / methods*

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18