Reduction of coronary flow reserve in areas with and without ischemia on stress perfusion imaging in patients with coronary artery disease: a study using oxygen 15-labeled water PET

J Nucl Cardiol. 2003 May-Jun;10(3):275-83. doi: 10.1016/s1071-3581(02)43243-6.

Abstract

Background: Myocardial perfusion single photon emission computed tomography (SPECT) occasionally fails to detect coronary stenosis in patients with coronary artery disease (CAD). We evaluated coronary flow reserve (CFR) using oxygen 15-labeled water in areas with and without ischemia on technetium 99m tetrofosmin stress perfusion SPECT in patients with angiographically documented CAD.

Methods and results: Twenty-seven patients with CAD and eleven age-matched normal subjects were studied. Baseline myocardial blood flow (MBF) and MBF during hyperemia induced by intravenous adenosine triphosphate infusion (0.16 mg. kg(-1). min(-1)) were determined with the use of O-15-labeled water positron emission tomography, and the CFR was calculated. Tc-99m tetrofosmin stress/rest SPECT was performed for comparison. On the basis of the results of coronary angiography and SPECT, coronary segments were divided into 3 types: segments with coronary stenosis and a perfusion abnormality on stress SPECT imaging (group A, n = 16), segments with coronary stenosis without a perfusion abnormality (group B, n = 42), and remote segments with no coronary stenosis or perfusion abnormality (group C, n = 18). Baseline MBF values were similar among the 3 groups. CFR in group A was lower (1.82 +/- 0.54) than in group B (2.22 +/- 0.87, P <.05), in group C (2.92 +/- 1.21, P <.01), and in normal segments (3.86 +/- 1.24, P <.001). CFR in group B was lower than in group C (P <.02) and in normal segments (P <.001). CFR in group C was lower than in normal segments (P <.02).

Conclusions: Areas with a perfusion abnormality on stress SPECT had reduced CFR. In the areas without a perfusion abnormality and with coronary stenosis, lowering of CFR was intermediate between the areas with a perfusion abnormality and remote segments. Moreover, CFR was slightly, but significantly, lower in remote segments in patients with CAD compared with normal segments.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Blood Pressure / physiology
  • Coronary Angiography
  • Coronary Circulation / physiology*
  • Coronary Stenosis / diagnosis
  • Coronary Stenosis / physiopathology*
  • Exercise Test
  • Female
  • Humans
  • Male
  • Middle Aged
  • Organophosphorus Compounds*
  • Organotechnetium Compounds*
  • Oxygen Radioisotopes*
  • Radiopharmaceuticals*
  • Tomography, Emission-Computed
  • Tomography, Emission-Computed, Single-Photon

Substances

  • Organophosphorus Compounds
  • Organotechnetium Compounds
  • Oxygen Radioisotopes
  • Radiopharmaceuticals
  • technetium tc-99m tetrofosmin