Establishment of radioactive astatine and iodine uptake in cancer cell lines expressing the human sodium/iodide symporter

Eur J Nucl Med Mol Imaging. 2002 Jul;29(7):842-54. doi: 10.1007/s00259-002-0784-7. Epub 2002 Apr 11.

Abstract

The sodium/iodide symporter (NIS) has been recognized as an attractive target for radioiodine-mediated cancer gene therapy. In this study we investigated the role of human NIS for cellular uptake of the high LET alpha-emitter astatine-211 ((211)At) in comparison with radioiodine as a potential radionuclide for future applications. A mammalian NIS expression vector was constructed and used to generate six stable NIS-expressing cancer cell lines (three derived from thyroid carcinoma, two from colon carcinoma, one from glioblastoma). Compared with the respective control cell lines, steady state radionuclide uptake of NIS-expressing cell lines increased up to 350-fold for iodine-123 ((123)I), 340-fold for technetium-99m pertechnetate ((99m)TcO(4)(-)) and 60-fold for (211)At. Cellular (211)At accumulation was found to be dependent on extracellular Na(+) ions and displayed a similar sensitivity towards sodium perchlorate inhibition as radioiodide and (99m)TcO(4)(-) uptake. Heterologous competition with unlabelled NaI decreased NIS-mediated (211)At uptake to levels of NIS-negative control cells. Following uptake both radioiodide and (211)At were rapidly (apparent t(1/2) 3-15 min) released by the cells as determined by wash-out experiments. Data of scintigraphic tumour imaging in a xenograft nude mice model of transplanted NIS-modified thyroid cells indicated that radionuclide uptake in NIS-expressing tumours was up to 70 times ((123)I), 25 times ((99m)TcO(4)(-)) and 10 times ((211)At) higher than in control tumours or normal tissues except stomach (3-5 times) and thyroid gland (5-10 times). Thirty-four percent and 14% of the administered activity of (123)I and (211)At, respectively, was found in NIS tumours by region of interest analysis ( n=2). Compared with cell culture experiments, the effective half-life in vivo was greatly prolonged (6.5 h for (123)I, 5.2 h for (211)At) and preliminary dosimetric calculations indicate high tumour absorbed doses (3.5 Gy/MBq(tumour) for (131)I and 50.3 Gy/MBq(tumour) for (211)At). In conclusion, NIS-expressing tumour cell lines of different origin displayed specific radionuclide uptake in vitro and in vivo. We provide first direct evidence that the high-energy alpha-emitter (211)At is efficiently transported by NIS. Application of (211)At may direct higher radiation doses to experimental tumours than those calculated for (131)I. Thus, (211)At may represent a promising alternative radionuclide for future NIS-based tumour therapy.

Publication types

  • Comparative Study

MeSH terms

  • Adenocarcinoma / diagnostic imaging
  • Adenocarcinoma / genetics
  • Adenocarcinoma / metabolism
  • Adenocarcinoma, Papillary / diagnostic imaging
  • Adenocarcinoma, Papillary / genetics
  • Adenocarcinoma, Papillary / metabolism
  • Animals
  • Astatine / pharmacokinetics*
  • Biomarkers, Tumor / genetics
  • Biomarkers, Tumor / metabolism*
  • Colonic Neoplasms / diagnostic imaging
  • Colonic Neoplasms / genetics
  • Colonic Neoplasms / metabolism*
  • Gene Expression
  • Glioblastoma / diagnostic imaging
  • Glioblastoma / genetics
  • Glioblastoma / metabolism
  • Humans
  • Iodine Radioisotopes / pharmacokinetics*
  • Mice
  • Mice, Nude
  • Neoplasm Transplantation
  • Radionuclide Imaging
  • Radiopharmaceuticals / pharmacokinetics
  • Reference Values
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Sodium Pertechnetate Tc 99m / pharmacokinetics
  • Symporters / genetics
  • Symporters / metabolism*
  • Thyroid Neoplasms / diagnostic imaging
  • Thyroid Neoplasms / genetics
  • Thyroid Neoplasms / metabolism*
  • Tissue Distribution
  • Tumor Cells, Cultured

Substances

  • Biomarkers, Tumor
  • Iodine Radioisotopes
  • Radiopharmaceuticals
  • Symporters
  • sodium-iodide symporter
  • Sodium Pertechnetate Tc 99m
  • Astatine