CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

Eur J Nucl Med Mol Imaging. 2002 Mar;29(3):346-50. doi: 10.1007/s00259-001-0698-9.

Abstract

With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT10, CT40, CT80 and CT120) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET(CT10)-PET(CT120). In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET(CT10)-PET(CT120). In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68Ge sources were employed for the attenuation correction of the FDG emission scan (PET(CT80), PET(68Ge)). Uptake values and lesion size in 26 lesions were compared on PET(CT80) and PET(68Ge). In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET(CT80) and PET(68Ge). In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68Ge attenuation correction are compared.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Calibration
  • Female
  • Fluorodeoxyglucose F18
  • Germanium
  • Humans
  • Image Enhancement
  • Male
  • Middle Aged
  • Neoplasm Staging / methods
  • Neoplasms / diagnostic imaging*
  • Radiographic Image Enhancement / methods*
  • Radioisotopes
  • Radiopharmaceuticals
  • Sensitivity and Specificity
  • Tomography, Emission-Computed / methods*
  • Tomography, X-Ray Computed / methods*

Substances

  • Radioisotopes
  • Radiopharmaceuticals
  • Germanium
  • Fluorodeoxyglucose F18