[Estimation and optimization of the use of standard arterial input function for split-dose administration of N-isopropyl-p[123I]iodoamphetamine]

Kaku Igaku. 2002 Feb;39(1):13-20.
[Article in Japanese]

Abstract

Use of a standard arterial input function and calibrating it by a single blood sample or a continuous arterial blood sample has been researched for a repeat CBF assessment with split-dose administration of N-isopropyl-p[123I]iodoamphetamine (IMP).

Methods: The study population consisted of 5 normal volunteers and 5 patients with cerebrovascular disease. IMP was injected twice (111 MBq/2 ml each) into the anti-cubital vein at a constant infusion speed for 1 min. The arterial input function was monitored during the study including a continuous measurement of radioactivity concentration of both the whole-blood and the octanol-soluble component (Real-Input Function, RIF). Standard input function was determined, and was calibrated either by a single blood sample or a continuous blood sample to estimate the Estimated-Input Function (EIF). Area-Under-the Curve (AUC) was then compared between RIF and EIF.

Results: In case EIF was estimated with a single blood sample, the minimum error of estimated AUC was obtained when calibrated at 7 minutes after either the 1st or 2nd injections. Deviation of AUC for [0, 30] was +/- 6.6%, and +/- 5.0%, respectively. If calibrated with a continuous blood sample, the minimum error of AUC with the continuous blood sampling period of 10 min for [0, 30] and [30, 60] was +/- 5.3% and +/- 4.0%, respectively.

Conclusions: AUC of EIF with either a single or continuous blood sampling appeared to have reasonably small errors, suggesting the validity of the use of standardized input function in the split-dose IMP SPECT.

MeSH terms

  • Adult
  • Aged
  • Blood Specimen Collection / methods
  • Calibration / standards
  • Cerebrovascular Circulation
  • Cerebrovascular Disorders / diagnostic imaging
  • Cerebrovascular Disorders / physiopathology
  • Female
  • Humans
  • Iodine Radioisotopes / administration & dosage*
  • Iodine Radioisotopes / standards
  • Iofetamine / administration & dosage*
  • Iofetamine / standards
  • Male
  • Middle Aged
  • Radiopharmaceuticals / administration & dosage*
  • Radiopharmaceuticals / standards
  • Tomography, Emission-Computed, Single-Photon / methods
  • Tomography, Emission-Computed, Single-Photon / standards*