Prospective evaluation of delayed technetium-99m sestamibi SPECT scintigraphy for preoperative localization of primary hyperparathyroidism

Surgery. 2002 Feb;131(2):149-57. doi: 10.1067/msy.2002.119817.

Abstract

Background: Delayed technetium-99m sestamibi single photon emission computed tomography (SPECT) scans were prospectively analyzed in a large series of patients with primary hyperparathyroidism.

Methods: Three hundred thirty-eight patients underwent sestamibi-SPECT and were explored. Prospective data included preoperative demographics, clinical, sestamibi, and operative findings, laboratory values, and pathologic and follow-up laboratory results from all patients.

Results: Between 1994 and 2000, 287 unexplored patients (85%) and 51 re-explored patients (15%) participated. The abnormal parathyroid glands excised from 336 of 338 patients included 299 single adenomas (88%) and 23 double adenomas (7%), and 14 patients had multigland hyperplasia (4%). Sestamibi SPECT correctly lateralized 349 of 400 abnormal parathyroid glands, with an overall sensitivity of 87%, an accuracy of 94%, and a positive predictive value of 86%. Precise localization occurred in 82% of the abnormal parathyroid glands. Sestamibi sensitivity was similar in unexplored (87%) and reoperative (92%) cases; two hundred eighty-six of 299 (96%) solitary adenomas, 38 of 46 (83%) double adenomas, but only 25 of 55 (45%) hyperplastic glands were identified. The mean weight of the true-positive glands (1252 +/- 1980 mg) was greater than that of the false-negative glands (297 +/- 286 mg) (P <.005). Three patients had persistent primary hyperparathyroidism, in spite of the excision of sestamibi-identified lesions in 2 cases. Follow-up indicated curative resection in 99% of the unexplored cases and 94% of the remedial cases.

Conclusions: Sestamibi SPECT is highly accurate for the localization of parathyroid adenomas in unexplored and re-explored cases, where it is often the only imaging required. Its sensitivity is limited in multiglandular disease.

MeSH terms

  • Adenoma / diagnostic imaging*
  • Adenoma / surgery
  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Humans
  • Hyperparathyroidism / diagnosis*
  • Hyperparathyroidism / surgery
  • Male
  • Middle Aged
  • Parathyroid Neoplasms / diagnostic imaging*
  • Parathyroid Neoplasms / surgery
  • Prospective Studies
  • Sensitivity and Specificity
  • Technetium Tc 99m Sestamibi*
  • Tomography, Emission-Computed, Single-Photon*

Substances

  • Technetium Tc 99m Sestamibi