Detection of myocardial viability in ischemic-reperfused rat hearts by Tc-99m sestamibi kinetics

J Nucl Cardiol. 2001 Nov-Dec;8(6):677-86. doi: 10.1067/mnc.2001.117687.

Abstract

Background: The purpose of this study was to evaluate technetium 99m sestamibi (MIBI) kinetics in assessing myocardial viability in hearts subjected to different ischemia-reperfusion treatments, resulting in graded severity of injury.

Methods and results: Sixteen isolated Krebs-Henseleit-perfused rat hearts were divided into 3 groups: control (flow, 12 mL/min; n = 5), ischemic-reperfused with glucose (IR+G, n = 6), and ischemic-reperfused without glucose (IR-G, n = 5). MIBI (11.1 mBq [300 microCi]) was infused for 60 minutes (uptake), followed by a 60-minute clearance. MIBI uptake (percent injected dose per gram) was significantly decreased in the IR+G (2.07 +/- 0.31) and IR-G groups (2.03 +/- 0.23; P = not significant with IR+G) compared with the control group (3.06 +/- 0.25, P <.05). Fractional washout of MIBI was more rapid in the IR-G group (72.7% +/- 3.9%, P <.05) than in the control (21.9% +/- 1.9%) and IR+G groups (20.3% +/- 1.7%). End retention (percent injected dose per gram) of MIBI in the IR-G (0.60 +/- 0.12) and IR+G groups (1.60 +/- 0.18) was significantly less than in the control group (2.30 +/- 0.11, P <.05), respectively. The retention in the IR-G group was less than in the IR+G group (P <.05). Creatine kinase assay, triphenyltetrazolium chloride staining, and transmission electron microscopy analysis demonstrated more serious myocardial damage in the IR-G group than in the IR+G group. End MIBI activity was highly correlated with myocardial viability determined by triphenyltetrazolium chloride staining (r = 0.94; P <.05) and creatine kinase assay (r = -0.86; P <.05).

Conclusions: Clearance of Tc-99m sestamibi is sensitive to metabolic states and may be used for assessment of ongoing myocardial damage.

MeSH terms

  • Animals
  • Coloring Agents
  • Creatine Kinase / blood
  • Disease Models, Animal
  • Heart / diagnostic imaging*
  • Heart / physiopathology*
  • Hemodynamics / physiology
  • Male
  • Metabolic Clearance Rate / physiology
  • Microscopy, Electron
  • Myocardial Ischemia / blood
  • Myocardial Ischemia / diagnostic imaging*
  • Myocardial Ischemia / physiopathology*
  • Myocardial Reperfusion Injury / blood
  • Myocardial Reperfusion Injury / diagnostic imaging*
  • Myocardial Reperfusion Injury / physiopathology*
  • Myocardium / pathology*
  • Myocardium / ultrastructure*
  • Radionuclide Imaging
  • Radiopharmaceuticals / pharmacokinetics*
  • Rats
  • Rats, Sprague-Dawley
  • Technetium Tc 99m Sestamibi / pharmacokinetics*
  • Tetrazolium Salts
  • Time Factors

Substances

  • Coloring Agents
  • Radiopharmaceuticals
  • Tetrazolium Salts
  • triphenyltetrazolium
  • Technetium Tc 99m Sestamibi
  • Creatine Kinase