Unexplained rising carcinoembryonic antigen (CEA) in the postoperative surveillance of colorectal cancer: the utility of positron emission tomography (PET)

Eur J Cancer. 2001 May;37(7):862-9. doi: 10.1016/s0959-8049(01)00049-1.

Abstract

The aim of the study was to evaluate the use of positron emission tomography with [18F]-fluorodeoxyglucose (FDG-PET) in patients with unexplained rising carcinoembryonic antigen (CEA) in the postoperative surveillance of colorectal cancer. 50 consecutive patients with elevated CEA levels and a completely normal (n=31) or equivocal (n=19) conventional diagnostic work-up (CDW) were retrospectively selected. All PET images were reviewed with full knowledge of the CDW. The gold standard consisted of histology, or clinical follow-up of more than 1 year. Recurrent disease was established in 56 lesions in 43 patients. On a patient-based analysis, the sensitivity of FDG-PET was 34/43 (79%), and the positive predictive value 34/38 (89%). In 14/50 patients (28%), the FDG-PET findings led to a surgical resection with curative intent. On a lesion-based analysis, FDG-PET detected 42/56 lesions (sensitivity: 75%), the positive predictive value was 79% (42/53). These results demonstrate that FDG-PET can have a clear impact on patient management in patients with an unexplained elevation in CEA levels.

MeSH terms

  • Adult
  • Aged
  • Carcinoembryonic Antigen / blood*
  • Colorectal Neoplasms / blood
  • Colorectal Neoplasms / diagnostic imaging*
  • Colorectal Neoplasms / surgery
  • False Negative Reactions
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Male
  • Middle Aged
  • Neoplasm Recurrence, Local / blood
  • Neoplasm Recurrence, Local / diagnostic imaging
  • Postoperative Care / methods
  • Radiopharmaceuticals
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, Emission-Computed / methods*

Substances

  • Carcinoembryonic Antigen
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18