Clinical evaluation of no-carrier-added meta-[123I]iodobenzylguanidine for myocardial scintigraphy

Eur J Nucl Med. 2000 Mar;27(3):302-7. doi: 10.1007/s002590050037.

Abstract

In clinical and research studies, images obtained using carrier-added meta-[123I]iodobenzylguanidine (c.a. [123I]MIBG) have shown quite variable quality, with varying levels of uptake in lung, liver and mediastinum; this is a significant problem for quantification of the myocardial uptake by means of region ratios. First experimental and preliminary human data in respect of no-carrier-added (n.c.a.) [123I]MIBG are indicative of improved imaging quality. The aim of the present study was to evaluate the clinical value of myocardial scintigraphy with n.c.a. [123I]MIBG in patients with tachyarrhythmias. The study population comprised 24 patients with tachyarrhythmogenic diseases routinely studied by cardiac single-photon emission tomography (SPET) with [123I]MIBG. Twelve of the 24 patients were studied with c.a. [123I]MIBG (seven females and five males; mean age 42+/-13 years, range 20-60 years), whereas the other 12 were studied with n.c.a. [123I]MIBG (ten females, two males; mean age 41+/-11 years, range 18-60 years, P=NS). For quantification of the specific uptake in the different organs, count ratios were calculated on SPET images acquired 4 h p.i. Visual analysis of all [123I]MIBG scans showed improved image quality (improved contrast between heart and neighbouring organs) in n.c.a. studies as compared with c.a. studies. A significantly higher heart/left atrial blood ratio was found in the n.c.a. studies as compared with the c.a. studies (10.3+/-3.2 vs 5.3+/-1.3, P=0.0003); furthermore, significantly higher heart/lung and heart/liver ratios (2.5+/-0.6 vs 1.5+/-0.3, P=0.0002, and 0.8+/-0.2 vs 0.6+/-0.1, P=0.0006, respectively) were obtained in the c.a. studies, whereas lung/left atrial blood and liver/left atrial blood ratios showed no significant differences (4.2+/-1.3 vs 3.6+/-1.1, P=0.39, and 13.7+/-5.2 vs 9.6+/-2.2, P=0.21, respectively). In conclusion, the use of n.c.a. [123I]MIBG yields a significantly higher myocardial uptake associated with improvement in contrast between the heart and neighbouring organs and is therefore superior to the commercially available c.a. [123I]MIBG for use in clinical and research studies of the myocardial presynaptic sympathetic nervous system. Furthermore, our data indicate that for quantification the use of a left atrial blood reference region of interest, which is only available on SPET studies, is to be recommended.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • 3-Iodobenzylguanidine*
  • Adolescent
  • Adult
  • Female
  • Heart / diagnostic imaging*
  • Heart / innervation
  • Humans
  • Iodine Radioisotopes*
  • Male
  • Middle Aged
  • Radiopharmaceuticals*
  • Tachycardia, Ventricular / diagnostic imaging
  • Tomography, Emission-Computed, Single-Photon*

Substances

  • Iodine Radioisotopes
  • Radiopharmaceuticals
  • 3-Iodobenzylguanidine