Positron emission tomographic imaging with fluorodeoxyglucose isefficacious in evaluating malignant pulmonary disease

J Thorac Cardiovasc Surg. 1999 Apr;117(4):719-27. doi: 10.1016/S0022-5223(99)70292-8.

Abstract

Objective: Positron emission tomography (PET), when used with the intravenously administered radiopharmaceutical F-18 fluorodeoxyglucose (FDG), has the potential to help in the evaluation of patients with lung cancer because the radiopharmaceutical is concentrated by metabolically active cells. We conducted a retrospective study of PET-FDG in 96 patients evaluated at our institution over the past 2 years for suspected primary pulmonary neoplasms. PET-FDG results were compared with the findings of computed tomographic scans on the same patients. All patients underwent surgical exploration with or without resection of the malignant tumors. Sites of potential malignancy were subjected to biopsy and/or excision, with subsequent pathologic evaluation.

Results: A total of 96 patients with suspected or proven primary pulmonary malignant disease were evaluated. Sixty-six patients had histologically confirmed malignant tumors, and 30 had benign masses histologically. PET-FDG had an accuracy of detecting malignancy in pulmonary lesions of 92% (sensitivity 97%; specificity 89%). A total of 111 surgically sampled sites were from lymph nodes. PET-FDG was accurate in predicting the malignancy of nodes in 91% of instances, whereas computed tomography was correct in 64%. The sensitivity, specificity, and predictive accuracy of PET in detecting metastatic lymphadenopathy in mediastinal lymph nodes were 98%, 94%, and 95%, respectively. PET-FDG also changed the M stage in 8 (12%) patients (6 with and 2 without metastases). The 6 malignant (positive) lesions were correctly identified by PET-FDG, and the 2 without tumor were accurately predicted as benign (negative).

Conclusion: These initial results suggest that PET-FDG is highly accurate in identifying and staging lung cancer. PET-FDG also appears to be more accurate in detecting metastatic mediastinal lymphadenopathy than computed tomographic scan.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Female
  • Fluorine Radioisotopes*
  • Fluorodeoxyglucose F18*
  • Humans
  • Lung Neoplasms / diagnostic imaging*
  • Lung Neoplasms / epidemiology
  • Lymphatic Metastasis
  • Male
  • Predictive Value of Tests
  • Radiopharmaceuticals
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, Emission-Computed*
  • Tomography, X-Ray Computed

Substances

  • Fluorine Radioisotopes
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18