In vitro and in vivo pre-clinical analysis of a F(ab')2 fragment of panitumumab for molecular imaging and therapy of HER1-positive cancers

Abstract

Background

The objective of this study was to characterize the in vitro and in vivo properties of the F(ab')2 fragment of panitumumab and to investigate its potential for imaging and radioimmunotherapy.

Methods

The panitumumab F(ab')2 was generated by enzymatic pepsin digestion. After the integrity and immunoreactivity of the F(ab')2 was evaluated, the fragment was radiolabeled. In vivo studies included direct quantitation of tumor targeting and normal organ distribution of the radiolabeled panitumumab F(ab')2 as well as planar γ-scintigraphy and PET imaging.

Results

The panitumumab F(ab')2 was successfully produced by peptic digest. The F(ab')2 was modified with the CHX-A"-DTPA chelate and efficiently radiolabeled with either 111In or 86Y. In vivo tumor targeting was achieved with acceptable uptake of radioactivity in the normal organs. The tumor targeting was validated by both imaging modalities with good visualization of the tumor at 24 h.

Conclusions

The panitumumab F(ab')2 fragment is a promising candidate for imaging of HER1-positive cancers.

Background

Monoclonal antibodies (mAb) have been used in medicine for nearly three decades for purposes including imaging and therapy due to their selectivity for specific targets [1]. While intact monoclonal antibody molecules are still most commonly used, they may not necessarily be the most efficient or desired molecular form depending on the application. Because of their relatively large size (approximately 150 kD), intact mAbs tend to have unfavorable imaging kinetics, relatively poor tumor penetration, and present with the potential for eliciting host antibody responses [2–7]. The solution to these myriad obstacles has been to reduce the size of intact antibodies to smaller forms or fragments, achieved either through enzymatic cleavage or by genetic engineering. The latter strategy requires a serious commitment of time and resources while enzymatic methods for generating monovalent or bivalent fragments of a mAb is somewhat facile with a lesser investment incurred.

The bivalent F(ab')2 antibody fragment can be generated by cleaving the antibody on the carbonyl side of cysteinyl residues, below the disulfide bonds with pepsin [8]. This results in an Fc and an F(ab')2 fragment [9]. The removal of the Fc portion during digestion also removes the potential of binding with Fc receptors thus reducing non-specific interactions [10]. The average molecular weight of the F(ab')2 fragment is approximately 110 kD.

Radiolabeled mAbs are utilized in applications that include monitoring of tumor response to therapy, detection of metastatic lesions, dosimetric calculations, and therapy [10, 11]. Again, mAb fragments may be preferable for several reasons. The removal of the Fc segment could reduce the non-specific distribution in vivo of the mAb via the Fc receptors found on normal cells. F(ab')2 fragments differ in their pharmacokinetic characteristics compared to intact antibodies resulting in distinct blood clearance and tumor localization patterns, clearing faster from the circulation than intact antibody while demonstrating better penetration into tumor sites [7, 12–19]. The rapid clearance from the blood compartment by F(ab')2 results in a higher signal-to-noise ratio at earlier time points. A more favorable scenario for the imaging of patients is thus provided.

The smaller size and rapid clearance of antibody fragments such as F(ab')2 should also lower their immunogenicity potential, reducing the risk of patients developing a humoral response against the antibody fragment, and potentially permitting repeated treatment of patients [20]. The ability to administer multiple doses of mAb for either therapy or imaging has not been a trivial consideration in the management of cancer patients.

Panitumumab (ABX-EGF, Vectibixâ„¢, Amgen, Thousand Oaks, CA, USA) is a fully human IgG2 mAb that binds to the epidermal growth factor receptor (EGFR) with high affinity [21]. Panitumumab gained FDA-approval in 2006 for the treatment of patients with EGFR expressing metastatic colorectal carcinoma with disease progression while on or following fluoropyrimidine-, oxaliplatin-, or irinotecan-containing chemotherapy regimens [22]. Panitumumab has been well tolerated in clinical trials and as a result, close observation of patients has not been required nor has pre-medication with antihistamines [23]. The intact antibody has been shown to be successfully radiolabeled with 111In in high yields and has demonstrated excellent tumor targeting with low normal tissue uptake [24, 25]. Panitumumab has also been successfully used for positron-emission tomography (PET) imaging using 86Y [26, 27].

Extensive studies have been performed on the intact panitumumab; to date, there are no reports utilizing a fragment of panitumumab for either imaging or therapeutic applications. This paper represents the first in vitro and in vivo characterization of panitumumab F(ab')2 fragment with an emphasis on its evaluation towards both imaging and therapeutic applications.

Materials and methods

Preparation of F(ab')2 fragments

Panitumumab (Amgen) was dialyzed against 0.1 M sodium acetate, pH 4, using a 10 kD molecular-weight cut-off (MWCO) dialysis cassette (Pierce, Rockford, IL, USA). The solution was changed three times a day over the course of 4 days. The total quantity of recovered protein was determined by absorbance at 280 nm. To determine the optimal digestion time, panitumumab (250 μg) was digested at 37°C for 1, 2, 4, 6, 8 h and overnight with 2% (2.5 μg) pepsin (Sigma, St.Louis, MO, USA). Enzymatic activity was halted with the addition of 25 μL of 0.15 M carbonate solution. The digests were then analyzed by polyacrylamide gel electrophoresis (sodium dodecyl sulfate (SDS)-PAGE) using a 4-20% tris-glycine gel (Invitrogen, Carlsbad, CA, USA); samples without pepsin kept at 4°C and 37°C were included for comparison. Samples (25 μg) were applied to the gels both with and without β-mercaptoethanol in the sample buffer.

Larger preparations of panitumumab F(ab')2 were then generated in two stages. Conditions of the peptic digest were confirmed by producing F(ab')2 fragments using 100 mg of panitumumab. Following an overnight digestion with 2% pepsin at pH 4 in 0.1 M sodium acetate, the preparation was analyzed by size-exclusion high-performance liquid chromatography (SE-HPLC) and then dialyzed against phosphate-buffered saline (PBS) over the course of 4 days, three changes per day. The final protein concentration of the panitumumab F(ab')2 was determined by the Lowry method using a BSA standard [28] and the product was analyzed by SDS-PAGE. Upon completion of the analysis, F(ab')2 fragments were then prepared from 1 g of panitumumab. In this situation, a tangential flow filtration system (Millipore, Billerica, MA, USA) was used to exchange the preparation into PBS.

F(ab')2 fragments of trastuzumab and HuM195, an anti-CD33 mAb (a gift from Dr. McDevitt, Memorial Sloan Kettering Cancer Center) were also prepared using the conditions described for panitumumab.

Conjugation and radiolabeling of panitumumab F(ab')2

Panitumumab F(ab')2 was conjugated with the bifunctional acyclic trans-cyclohexyl-diethylenetriamine-pentaacidic acid (CHX-A"-DTPA) chelate by a modification of established methods using fivefold, tenfold, and 20-fold molar excess of chelate to panitumumab F(ab')2 [29, 30]. The final concentration was determined by the Lowry method. The average number of CHX-A"-DTPA molecules linked to the panitumumab F(ab')2 was determined using a spectrophotometric assay based on the titration of yttrium-Arsenazo(III) complex [31]. The HuM195 F(ab')2 fragment was conjugated with a tenfold molar excess of CHX-A"-DTPA.

Radiolabeling of the panitumumab F(ab')2-CHX-A"-DTPA with either 111In or 86Y was performed as previously described [32]. Radio-iodination of panitumumab (50 μg) with Na125I (0.5-1 mCi; PerkinElmer, Shelton, CT, USA) was performed using Iodo-Gen (Pierce Chemical, Rockford, IL, USA) [29, 33].

Cell culture

LS-174T cells, kindly provided by Dr. J. Greiner, NCI, were grown in Dulbecco's Modified Eagle's Medium, supplemented with 10% FetalPlex (Gemini Bio-Products, Woodland, CA, USA), 1 mM L-glutamine and 1 mM non-essential amino acids (NEAA). All media and supplements were obtained from Quality Biological (Gaithersburg, MD, USA) or Lonza (Walkersville, MD, USA). The cells were maintained in a 5% CO2 and 95% air-humidified incubator.

Radioimmunoassays

The immunoreactivity of the panitumumab F(ab')2 was evaluated in a competition radioimmunoassay using purified human epidermal growth factor receptor (hEGFR; Sigma-Aldrich). Fifty nanograms of hEGFR in 100 μL of PBS containing Mg+2 and Ca+2 was added to each well of a 96-well plate. Following an overnight incubation at 4°C, the solution was removed and 1% bovine serum albumin (BSA) in phosphate-buffered saline (BSA/PBS,150 μL) was added to each well for 1 h at ambient temperature. The solution was removed and serial dilutions (1,000-17 ng) of the panitumumab F(ab')2 (50 μL) were added to the wells in triplicate; one set of wells received only BSA/PBS. After adding 125I-panitumumab (28 nCi in 50 μL) to each well, the plates were incubated at 37°C. At the end of the 4 h incubation, the solution was removed and the wells were washed three times with BSA/PBS. The radioactivity was removed from the wells by adding 0.2 N NaOH and adsorbing the liquid with cotton filters. The filters were then placed in 12 × 75 mm polypropylene tubes and counted in a γ-counter (WizardOne, Perkin Elmer, Shelton, CT, USA). The percent inhibition was calculated using the control (no competitor) and plotted. The panitumumab fragment was compared to intact panitumumab. Trastuzumab F(ab')2 was used as a negative control. All values were corrected for on a nanomolar basis.

The immunoreactivity of the 111In-panitumumab F(ab')2 was assessed in a radioimmunoassay as detailed previously using purified hEGFR [29, 34]. Serial dilutions of 111In-CHX-A"-panitumumab F(ab')2 (approximately 200,000 to 12,500 cpm in 50 μL of BSA/PBS) were added to the wells of a 96-well plate coated with 100 ng of hEGFR in duplicate. Following a 4 h incubation at 37°C, the wells were washed, the radioactivity removed and counted in a γ-scintillation counter. The percentage binding was calculated for each dilution and averaged. The specificity of the radiolabeled panitumumab F(ab')2 was confirmed by adding 10 μg of unlabeled panitumumab to one set of wells.

In vivo studies

Quantitation of tumor targeting

All animal care and experimental protocols were approved by the National Cancer Institute Animal Care and Use Committee. The in vivo behavior of the radioimmunoconjugate (RIC) F(ab')2 was assessed using LS-174T tumor bearing athymic mice (Charles River Laboratories, Wilmington, MA, USA). Four- to six-week old female mice received either subcutaneous (s.c.) injections in the flank with 2 × 106 cells in 0.2 mL of media containing 20% Matrigel ™(Becton Dickinson, Bedford, MA, USA) or intraperitoneal (i.p.) injections of 1 × 108 cells in 1 mL of media. Animals bearing s.c. tumors were used for the in vivo studies when the tumor diameter measured 0.4-0.6 cm. Mice with i.p. xenografts were utilized in studies at 4-5 days post-tumor implantation.

Tumor targeting was quantitated by injecting mice (n = 5 per time point) intravenously (i.v.) via tail vein or i.p. with 111In-CHX-A"-panitumumab F(ab')2 (approximately 7.5 μCi). The mice were euthanized at 24, 48, 72, 96, and 168 h. The blood, tumor, and major organs were collected, wet-weighed, and counted in a γ-scintillation counter. The percentage of injected dose per gram (%ID/g) was determined for each tissue. The averages and standard deviations are also presented.

Blood pharmacokinetics

Blood pharmacokinetics were performed with non-tumor bearing (n = 5) and mice (n = 5) bearing LS-174T (s.c. or i.p.) xenografts. 111In-CHX-A"-panitumumab F(ab')2 (approximately 7.5 μCi in 200 μL PBS) was administered by i.v. or i.p. injection, blood samples (10 μL) were collected in heparinized capillary tubes and the radioactivity measured in a γ-scintillation counter. The percent injected dose per milliliter (%ID/mL) was calculated for each of the samples and the average with the standard deviation plotted for each time point.

Imaging

γ-Scintigraphy was performed with tumor bearing mice to further validate the 111In-CHX-A"-panitumumab F(ab')2 tumor targeting. Imaging studies were performed with s.c. tumor bearing mice (n = 4) given i.v. injections of 111 In-CHX-A"-panitumumab F(ab')2 (approximately 100 μCi in 0.2 mL PBS). The mice were chemically restrained with 1.5% isoflurane (Abbott Laboratories, North Chicago, IL, USA) delivered in O2, using a model 100 vaporizer (SurgiVet, Waukesha, WI, USA) at a flow rate of approximately 1.0 L/min. Images (100,000 counts) were acquired at 24, 48, 72, and 96 h using MONICA (Mobile Nuclear Imaging Camera, NIH, Bethesda, MD, USA) [35]. Images were analyzed using NucLear Mac software (Scientific Imaging, Inc., Crested Butte, CO, USA).

PET imaging study was performed using the Advanced Technology Laboratory Animal Scanner (ATLAS, National Institutes of Health, Bethesda, MD, USA) as previously described [32–34]. Whole-body imaging studies (six bed positions, total acquisition time of 1 h per mouse) were carried out on mice anesthetized with 1.5% isoflurane on a temperature-controlled bed as described previously [27]. In brief, LS-174T tumor-bearing female athymic mice were injected i.v. with approximately 100 μCi of 86Y-CHX-A"-DTPA-panitumumab F(ab')2. The reconstructed images were processed and analyzed using AMIDE (A Medical Image Data Examiner) software program. To minimize spillover effects, regions of interest (ROIs) were drawn to enclose approximately 80-90% of the organ of interest, avoiding the edges. To minimize partial-volume effects caused by non-uniform distribution of the radioactivity in the containing volume, smaller ROIs were consistently drawn to enclose the organ. Upon completion of the imaging session, the mice were euthanized and biodistribution studies were performed to determine the correlation between PET-assessed in vivo percent of injected dose per cubic centimeter and biodistribution-determined percent of injected dose per gram.

Results

The studies as performed were designed to evaluate the in vitro and in vivo properties of the panitumumab-CHX-A" F(ab')2 fragment and assess the potential of this molecule for imaging and therapeutic applications. To determine the optimal (digestion) cleavage time, 2% pepsin was added to 250 μg panitumumab and incubated at 37°C. Aliquots were removed at 1, 2, 4, 6, 8, and 18 h. As determined by SDS-PAGE, near complete pepsin digestion of panitumumab to a F(ab')2 fragment appears to occur after 8 h, evident in Figure 1 by the loss of the higher-molecular-weight band of the intact IgG under non-reducing conditions (Figure 1a) and the transition of the heavy-chain band to a lower molecular weight when subjected to reduction with β-mercaptoethanol (Figure 1b).

Figure 1
figure 1

SDS-PAGE analysis of peptic digest of panitumumab IgG. Panitumumab was subjected to digestion with 2% pepsin at 37°C. At the specified time points, samples were neutralized and stored at 4°C until analyzed. The peptic digests were analyzed under non-reducing (a) and reducing (b) conditions.

Having determined the incubation time for the peptic digestion, 100 mg of panitumumab was digested overnight with 2% pepsin. When analyzed by SDS-PAGE, as expected, major bands were visualized corresponding to a molecular weight (Mr) of 79.4 under non-reducing conditions while two bands were evident at 25.1 and 22.4 kD after reduction (Figure 2a). Lower-molecular-weight (LMW) species at approximately 38 and 22 kD were also evident under non-reducing conditions. These LMW species, with a retention time of 24.2 min on SE-HPLC, comprised 30.5% of the reaction mixture, most likely representing pepsin and the Fc fragment (data not shown). The retention time of the panitumumab F(ab')2 was 36 min by SE-HPLC, consistent with a Mr of 89.1 kD using tandem TSK2000 and 4000 columns for the analysis. Following buffer exchange to phosphate-buffered saline and subsequent concentration of the F(ab')2 preparation using an Amicon Centriprep with a MWCO of 50 kD, the final product was again analyzed by SDS-PAGE and SE-HPLC: the LMW was no longer present as shown in Figure 2b. A final yield of 37.3 mg of panitumumab F(ab')2 was obtained as determined by protein quantitation by the Lowry method.

Figure 2
figure 2

SDS-PAGE analysis of panitumumab F(ab') 2 . The panitumumab F(ab')2 was evaluated by SDS-PAGE before (a) and after (b) the final step of buffer exchange and concentration using a Centriprep centrifugal filtration device. The fragment was applied to a 4-20% gel in the absence and presence of β-mercaptoethanol.

The peptic digest appears to have a modest effect on the immunoreactivity of the panitumumab F(ab')2 fragment. When analyzed in a competition radioimmunoassay, depicted in Figure 3, the concentration for 50% inhibition (IC50) for intact panitumumab IgG was 0.5 nM while the IC50 for the panitumumab F(ab')2 was 1 nM.

Figure 3
figure 3

Evaluation of panitumumab F(ab') 2 immunoreactivity in a competition radioimmunoassay. The immunoreactivity of panitumumab F(ab')2 (white circle) for purified EGFR was compared to panitumumab IgG (filled circle). The F(ab')2 of the anti-HER2 mAb, trastuzumab, (downward-pointing filled triangle) was used as a negative control.

Evaluating the potential of the panitumumab F(ab')2 for clinical imaging and radioimmunotherapy applications would require larger quantities of the F(ab')2. Therefore, a peptic digestion was performed with 1 g of panitumumab. As with the previous preparation, LMW species were detected by SE-HPLC which comprised approximately 34% of the digest mixture. For this larger preparation, a tangential flow filtration system with a 50 kD MWCO was used to eliminate the LMW species, exchange the buffer, and to also concentrate the F(ab')2. The final product, analyzed by SDS-PAGE and SE-HPLC, was found to be comprised of a single product consistent with the Mr of a F(ab')2 (data not shown). The final yield of this preparation was appreciably higher than the digestion of 100 mg with a final yield of 56%.

A trial conjugation of the panitumumab F(ab')2 with the acyclic ligand, CHX-A"-DTPA was then performed at a molar excess of 5:1, 10:1, and 20:1. These reactions resulted, respectively, in an average chelate to protein ratio of 2.9, 1.7, and 5.6 (Table 1). The immunoconjugates were evaluated in a competition radioimmunoassay to determine if the modification affected the immunoreactivity of the panitumumab F(ab')2 fragment. The modification with the CHX-A"-DTPA chelate had minimal effect on the immunoreactivity of the panitumumab F(ab')2 (Table 1). The IC50 for the 2.9, 1.7, and 5.6 was 0.6, 0.7, and 0.7 nM, respectively, compared to the unmodified panitumumab F(ab')2 IC50 of 0.5 nM.

Table 1 In vitro analysis of panitumumab F(ab')2 conjugated with CHX-A"-DTPA.

Each of the immunoconjugate preparations were radiolabeled with 111In and their characteristics compared. The specific activities ranged from 1.9 to 14.8 μCi/μg, with the labeling efficiency ranging from 13.9% to 49.4% (Table 1). When the radiolabeled panitumumab F(ab')2 fragments were incubated with purified hEGFR for 4 h at 37°C, 54.7% to 59.5% of the radioactivity was bound. The addition of 10 μg of unlabeled fragment, which reduced the percentage of bound radioactivity to an average of 3.5%, demonstrated the specificity of the RICS. Specificity of the radioimmunoassay was also demonstrated with the lack of binding (1.8%) with 111In- HuM195 F(ab')2. Based on these data, the preparation with 1.7 chelates, from the 10:1 molar excess reaction, was chosen for the remaining studies. In subsequent assays, specific binding of the RIC with hEGFR was as high as 72%.

Biodistribution studies were performed to quantitate tumor targeting and to determine the normal organ distribution of the 111In- CHX-A"-panitumumab F(ab')2 fragment. Athymic mice bearing LS-174T xenografts were injected (i.v.) with 111In- -panitumumab F(ab')2 (approximately 7.5 μCi), the results are presented in Table 2. At 24 h, the percentage of injected dose per gram of the 111In-panitumumab F(ab')2 in tumor was 21.42 ± 7.67 and remained at this level for 72 h at which time the percentage of injected dose per gram was 21.55 ± 6.22. The percentage of injected dose per gram then decreased to 8.01 ± 3.65 by 168 h. Of the normal organs, the highest percentage of injected dose per gram (13.13 ± 2.34) was observed in the kidney at 24 h which decreased to 2.66 ± 0.46 by 168 h. The next highest normal organ uptake was observed in the liver with a percentage of injected dose per gram of 8.01 ± 1.63 at 24 h that decreased to 3.38 ± 0.67 by 168 h. The blood percentage of injected dose per gram was 6.84 ± 2.30 at 24 h, but then steadily decreased to 0.08 ± 0.02 by the end of the study (168 h). All other organs began with their highest percentage of injected dose per gram at 24 h and steadily decreased to the end of the study.

Table 2 Tumor targeting and normal organ distribution of i

The blood pharmacokinetics of 111In-panitumumab F(ab')2 was evaluated in tumor- and non-tumor-bearing mice following i.v. and i.p. administration. In the absence of a tumor burden, i.v. injected RIC demonstrated a clearance from the blood compartment that was nearly twofold slower, for the both T1/2α- and T1/2β phase, than what was obtained in mice bearing s.c. LS-174T xenografts (Table 3). When non-tumor bearing mice were injected with the RIC by an i.p. route, the T1/2β phase was similar to what was obtained for the i.v. injected route; 18.6 h for the i.v. injected group and 19.3 h for the i.p.-injected group. In contrast to the i.v.-injected sets of mice, the clearance (T1/2β phase) of the RIC following i.p. injection in the mice bearing i.p. tumor xenografts was only 5.6 h longer than what was obtained in the mice that were tumor free.

Table 3 Biphasic analysis of blood pharmacokinetics of 111In- CHX-A"-panitumumab following i

Tumor targeting of the panitumumab F(ab')2 was also validated through the use of two imaging modalities, planar γ-scintigraphy, and positron-emission tomography (PET). The s.c. LS-174T tumors on the rear flank of the mice were clearly visualized by planar γ-scintigraphy (Figure 4a). Over the 4-day period that images were collected, not only does the 111In-labeled panitumumab remain in the tumor, but the RIC clears from the body.

Figure 4
figure 4

Validation of panitumumab F(ab') 2 as an imaging agent of HER1 positive tumors. (a) γ-Scintigraphy was performed with mice bearing LS-174T s.c. tumor xenografts. Following i.v. injection with approximately 100 μCi of 111In-CHX-A"-panitumumab F(ab')2, mice were imaged over a 4-d period. Positron-emission tomograhic (PET) using 86Y-CHX-A"-panitumumab F(ab')2. (b) Mice bearing s.c. LS-174T xenografts were injected i.v. with (50-60 μCi) of 86Y-CHX-A"-panitumumab F(ab')2 and imaged 1 and 2 days post-injection of the RIC. (c) Specificity was demonstrated by co-injecting 100 μg of panitumumab with the RIC and blocking uptake of the RIC by the tumor.

Imaging was also performed with 86Y-CHX-A"-DTPA-panitumumab F(ab')2 on the ATLAS. Mice bearing the LS-174T xenografts were injected i.v. with approximately 100 μCi (3 μg) of 86Y- panitumumab F(ab')2. Images were taken at 24 and 48 h; after the 48 h images were collected, the mice were euthanized and the tumor, blood, and normal organs were harvested to obtain direct counts to correlate with the quantitation by imaging. All of the tumors were clearly visualized for both days following injection of the RIC as shown in the maximum intensity image (Figure 4b). The blood pool (heart, lungs, liver) is visible in these images, but it appears to have decreased on the second day while the tumor uptake increased. Specificity is demonstrated by reduction in tumor uptake when 0.1 mg of unlabeled panitumumab was co-injected with the 86Y-labeled panitumumab F(ab')2 (Figure 4c).

Direct quantitation of the distribution of 86Y-panitumumab F(ab')2 fragment in the liver and tumor provided results similar to what was obtained with the 111In-labeled fragment (Figure 5a). The percentage of injected dose per cubic centimeter calculations from the images correlated (Table 4) with the ex vivo percentage of injected dose per gram quantitation (r2 = 0.91, p = 0.89). Finally, when the specific activity of the 86Y-panitumumab F(ab')2 was lowered by the addition of 15 μg of panitumumab F(ab')2 (Figure 5b); no mass effect was observed in the level of radioactivity in the blood, tumor, or normal organs as determined by imaging and ex vivo quantitation (Figure 5c and Table 4).

Figure 5
figure 5

Quantitation of tumor and normal organ distribution of 86 Y-CHX-A'-panitumumab F(ab') 2 . (a) Receptor-mediated uptake of 86Y-CHX-A"-panitumumab F(ab')2 of LS-174T tumor xenografts and normal organs 2 days post-injection of the RIC. Data represent the mean ± SEM from at least three determinations. (b) The specific activity of the 86Y- CHX-A"-panitumumab F(ab')2 was lowered by the addition of 15 μg of panitumumab F(ab')2. The mice were euthanized following the completion of the 48-h imaging session, the blood, tumor and normal organs were harvested and the radioactivity measured. (c) Comparison of the 48 h ex vivo quantitation at the two concentrations of panitumumab F(ab')2.

Table 4 Quantitation of tumor and liver uptake of 86Y-CHX-A"-panitumumab F(ab')2 by PET imaging.

As a prelude to: (1) utilizing the panitumumab F(ab')2 for monitoring response to radioimmunotherapy and (2) exploiting the panitumumab F(ab')2 as a targeting vector for radioimmunotherapy of disseminated peritoneal disease, direct quantitation of intraperitoneal (i.p.) tumor xenograft targeting was performed. The targeting of i.p. tumors by 111In-panitumumab F(ab')2 was evaluated using both an i.p. and i.v. injection route, the results of which are presented in Figure 6. Not unexpectedly, i.p. administration of the RIC resulted in excellent targeting of the i.p. tumors (Figure 6a). Peaking at 48 h, the tumor percentage of injected dose per gram was 45.67 ± 3.79 and declined to 8.50 ± 3.63 at 168 h. When mice bearing i.p. tumor xenografts were given an i.v. injection of the RIC, the peak tumor percentage of injected dose per gram was at a similar level to the aforementioned experiment; however, this maximum did not occur until 72 h (Figure 6b). The pattern of normal organ distribution in these last two studies was similar to what was obtained with the i.v. injected 111In-labeled panitumumab F(ab')2 already discussed.

Figure 6
figure 6

Tumor and normal organ distribution of 111 In-CHX-A"-panitumumab F(ab') 2 in mice ( n = 5) bearing i.p. LS-174T tumor xenografts were injected i.v. (a) or i.p. (b) with 111 In-CHX-A"-panitumumab F(ab') 2 (approximately 7.5 μCi). Mice were euthanized at the indicated times, blood, tumor, and organs were harvested, wet-weighed, and the radioactivity measured. The percentage of injected dose per gram with the standard deviations is plotted.

Discussion

The in vivo and in vitro properties of the intact panitumumab mAb has been previously described by Ray et al. [25] which included imaging by planar γ-scintigraphy. The potential of imaging EGFR-positive tumors for purposes of monitoring disease response to therapy and performing dosimetric calculations was successfully extended to PET imaging with 86Y-panitumumab [26, 36]. While the 111In-CHX-A"-panitumumab demonstrated tumor uptake in LS-174T xenografts [25], maximal localization of the intact mAb does not occur until 48-96 h post-injection [13]. The objective of this study was to evaluate the in vivo and in vitro properties of panitumumab F(ab')2 fragment and to assess its utility as a targeting agent in radioimmunodiagnostic and radioimmuntherapeutic protocols. To date, this report appears to be the first such characterization of a fragment generated from panitumumab.

Although intact monoclonal antibodies have been considered candidates for targeted therapy due to their specificity, with their long residence time in the blood of days to weeks, they are not ideal carriers for imaging probes; it is extremely difficult to perform serial imaging of less than several days [37, 38]. Early studies demonstrated that the size of antibody-based imaging agents are inversely related to their blood clearance; the clearance rate of Fab or Fab' > F(ab')2 > IgG [13, 15]. Covell et al. [15] found that the whole murine IgG was retained in the (mouse) body 17 times longer than F(ab')2. Consequently, normal tissue exposure is much greater with the intact antibody than it is for the fragment.

The Fab fragments, smaller in size, clear even faster than an F(ab')2 fragment and have been developed predominantly as imaging agents [13, 15, 39]. Their limitations pertain to the fact that they are monovalent and their molecular weight subjects them to efficient glomerular filtration. Monovalency often results in the loss of functional affinity and reduces the binding strength of the Fab or Fab' fragment as compared to the F(ab')2 or IgG [39, 40]. In 1983, Wahl and colleagues reported on a direct comparison of three radio-iodinated mAb forms, anti-CEA IgG, F(ab')2 and Fab using γ-scintigraphy. Interestingly, the F(ab')2 exhibited the fastest tumor localization [14]. At 2 days post-injection of the 131I-anti-CEA-F(ab')2 fragment tumor was clearly visualized. By the third day the images were equivalent to those obtained at 11 days with the intact mAb. The authors concluded that Fab fragments were not an optimal vector for imaging due to their rapid clearance, low accumulation in tumor and high renal accumulation. Similar observations have been noted with other mAbs. As reviewed by Tolmachev [40], 111In-DTPA-trastuzumab-Fab tumor uptake as compared to that of 111In-DTPA-trastuzumab-F(ab')2 is considerably lower. In contrast, an early clinical imaging study conducted by Delaloye et al. [19] compared 123I-labeled Fab and F(ab')2 fragments of an anti-carcinomembryonic antigen mAb in colorectal carcinoma patients for the detection of disease using emission-computed tomography. The Fab fragment was reported to have clearer images than those of the F(ab')2 fragment with a higher overall detection of tumor lesions. The authors postulate that the success of these studies was the result of careful selection and matching of the target, the targeting vehicle, and the radionuclide.

Based on these earlier reports and the importance of retaining affinity/avidity, the F(ab')2 fragment was selected for this investigation as the targeting vehicle to be exploited in imaging modalities, e.g., PET, planar γ-scintigraphy, MRI, and optical. In this study, F(ab')2 fragments were successfully generated from panitumumab by peptic digest and the protocol developed was readily scaled-up. The in vitro analysis, SDS-PAGE and SE-HPLC, indicated that the final product has a Mr of 79.4 and 89.1 kD, respectively, and retained immunoreactivity for HER1. Once the F(ab')2 fragment was generated, conjugation with the bifunctional chelate, acyclic CHX-A"-DTPA was performed for radiolabeling with medically relevant radionuclides such as 111In and 86Y which is also appropriate for radiolabeling with therapeutic radionuclides such as 177Lu, 213Bi, and 212Bi [41–43]. The conjugation was performed at three different molar ratios of chelate to panitumumab F(ab')2. The different ratios had minimal effect on the immunoreactivity of the panitumumab F(ab')2 as demonstrated by a competition radioimmunoassay. Furthermore, the specific binding of the immunoconjugate preparations with hEGFR was comparable following radiolabeling with 111In. Based on the results, the 10:1 molar excess ratio (1.7 chelate/antibody) was chosen for the remaining studies.

This represents the first report on the use of a panitumumab fragment for imaging applications. As such, comparisons to other mAb fragments will have to suffice in the discussion of the data reported herein. Smith-Jones (2004) and co-workers conjugated the macrocyclic ligand DOTA to trastuzumab F(ab')2. reporting an average of 6.3 chelates per F(ab')2 fragment and immunoreactivity of 81% [37]. No other in vitro assay data was reported, i.e., assessing the effect of the fragmentation of the mAb, or the chelate number, on the overall immunoreactivity of the mAb. A number of studies have investigated the use of F(ab')2 fragments with radio-iodines for imaging and radioimmunotherapy, making a direct comparison with a metallic radionuclide difficult [12, 18, 19, 44, 45]. For example, an F(ab')2 of the mAb14C5 was evaluated for the radioimmunodetection of non-small cell lung tumor xenografts [45]. Some targeting was observed; however, tumors were poorly visualized by γ-scintigraphy. More promising results were reported for the 125I-labeled F(ab')2 fragment of mAb B6.2 [12]. In this case, excellent tumor targeting was demonstrated by direct quantitation studies as well as γ-scintigraphy.

In contrast to panitumumab IgG, the F(ab')2 attains a higher percentage of injected dose per gram in the LS-174T s.c. tumor (21.42 ± 7.67) at an earlier time point (24 h) than the intact IgG (13.27 ± 8.40) following i.v. administration [25]. The F(ab')2 fragment may not achieve the same level of targeting, it is, however, retained in the tumor. In contrast to the intact IgG, the F(ab')2 is rapidly cleared from the blood compartment, evident by the biodistribution and pharmacokinetic data presented. At 24 h, the blood percentage of injected dose per gram of panitumumab F(ab')2 is approximately one-half of that reported for panitumumab IgG. The differential becomes even greater by 7 days. The blood pharmacokinetics of the panitumumab F(ab')2 in tumor-bearing mice reported here is consistent with that of other F(ab')2 fragments described in the literature [13]. Interestingly, when compared to panitumumab IgG, there is a "reversal" of the values for the T1/2α and β values of the tumor and non-tumor bearing mice. In the absence of a tumor burden, the T1/2α and β for IgG was approximately 5.2 and 3.8 times faster, respectively, than in the presence of tumor. In contrast, the T1/2α and β of the blood clearance for the 111In-panitumumab F(ab')2 was approximately two times faster in the tumor-bearing mice vs. in mice without a tumor burden. One explanation for this phenomenon is that murine FcRn cross-reacts with and will bind human IgG which results in prolonging its half-life in the mouse [38, 46]. The F(ab')2, lacking the Fc region, is likely cleared by phagocytic cells of the reticuloendothelial system.

The results reported herein are comparable to studies performed with F(ab')2 of other mAbs. In a study with 111In-DOTA-Herceptin F(ab')2, the tumor percentage of injected dose per gram was 20.4 ± 6.8 after 24 h. At the same time point, a tumor percentage of injected dose per gram of 21.42 ± 7.67 was obtained with 111In-CHX-A"-DTPA-panitumumab F(ab')2. Differences between the two studies are evident in renal uptake of the RICs. The kidney percentage of injected dose per gram of uptake 111In-CHX-A"-DTPA-panitumumab F(ab')2 was only 13.13% at 24 h compared to approximately 65% with 111In-DOTA -Herceptin F(ab')2 [37]. A F(ab')2 fragment of the recombinant anti-L1 CAM mAb, chCE7, has also been evaluated for PET imaging when radiolabeled with 64Cu and for radioimmunotherapy using 177Lu [47]. Maximal tumor uptake of the 177Lu-labeled RIC was observed at 24 h with an ID/g of 14.43 while maximum uptake for the 67/64Cu-labeled RIC occurred at 8 h. Unfortunately, kidney uptake with either of these radiolabeled chCE7 F(ab')2 preparations was greater than what was observed in the tumor at all time points of the study.

The panitumumab F(ab')2 also appears to be a potential vehicle for targeting disseminated intraperitoneal disease. Whether administered i.v. or i.p., excellent tumor targeting of the i.p. tumor xenografts was observed, with a tumor percentage of injected dose per gram as high as 45.66, 2.1-fold greater than the highest value calculated for the s.c. tumor following i.v. administration. Interestingly, the peak tumor percentage of injected dose per gram of both the s.c. and i.p. tumors following i.v. injection occurred at 72 h whereas the peak i.p. tumor value occurred at 48 h following i.p. injection of the panitumumab F(ab')2. Imaging studies, γ-scinitigraphy and PET, of the i.p. tumor model using these two injection routes are pending.

Studies from this laboratory and others have demonstrated the potential of panitumumab for the non-invasive monitoring of HER1-positive tumors and quantitating HER1 expression using modalities such as γ-scintigraphy, PET, and optical imaging [24, 25, 36, 48, 49]. By evidence of the tumor targeting, direct quantitation of tumor targeting suggests that the 111In-labeled panitumumab F(ab')2 is stable in vivo. This observation is also supported by the imaging studies related herein. This attribute may be due in part to the fact that panitumumab is of the IgG2 immunoglobulin subclass. In a series of dual-labeled experiments, Buchegger et al. [44] compared F(ab')2 fragments generated from chimeric mAb of three subclasses (IgG1, IgG2, and IgG4) directed against carcinoembryonic antigen. The in vivo studies revealed that the IgG2 F(ab')2 fragment had superior tumor targeting and possessed the longest biological half-life as well. The poorest results were obtained with the F(ab')2 of the IgG4. The radio-iodinated F(ab')2 fragment of chimeric 81C6, another IgG2 subclass mAb, has also been found stable and suitable for imaging applications [18].

The images presented here, both planar γ-scintigraphy and PET, indicate that there is excellent uptake of the panitumumab F(ab')2 by 24 h with decreasing background over the course of the imaging sessions, consistent with the studies conducted by Wahl and colleagues [14]. The ex vivo quantitation of tumor and tissue uptake (percentage of injected dose per gram) correlated with the quantitation (percentage of injected dose per cubic centimeter) performed from the PET images. These data were comparable to those obtained with panitumumab IgG, providing confidence in the suggestion that the panitumumab F(ab')2 would be useful in assessing tumor responses to therapy (i.e., estimating HER1 expression) and would provide accurate data for performing dosimetric calculations for radioimmunotherapy [36]. The caveat to translating the imaging of HER1 with panitumumab, either the intact IgG or a fragment, is whether or not human hepatocytes will be targeted. Clinical studies using 111In- or 99mTc-labeled cetuximab reported visualization of tumor burden in patients with squamous-cell carcinoma of the lung, head, and neck with significant hepatic uptake of radioactivity [50, 51]. Panitumumab may prove superior in this aspect. In pre-clinical studies, cetuximab has been observed to have a higher hepatic uptake of radioactivity than panitumumab [25, 29].

Alternative to enzymatically generated fragments of monoclonal antibodies are a variety of genetically engineered forms (i.e., sfv, minibody, diabody, domain-deleted) that are under evaluation for imaging and therapeutic applications. The valency and molecular weight of these mAb forms have been tailored to alter such biological properties as their blood residence time, tumor penetration, tumor residence time, renal clearance, and catabolic susceptibility [11, 39, 52–54]. Renal and hepatic uptake of many of these forms remains an obstacle when labeled with a metallic radionuclide limiting their potential for imaging to the radio-iodines or 18F.

This study demonstrates that F(ab')2 fragments of the anti-EGFR mAb panitumumab can be generated efficiently and quickly. The immunoreactivity of the panitumumab F(ab')2 fragment is comparable to the IgG. The immunoreactivity is retained on further modification with the chelating agent, acyclic CHX-A"-DTPA and subsequent radiolabeling. The study also demonstrated tumor targeting with LS-174T xenografts. Because of the bivalency, fast blood clearance, and deep tumor penetration, the panitumumab F(ab')2 fragment is a good candidate for imaging. Studies are continuing with the panitumumab F(ab')2 to further evaluate the role of panitumumab F(ab')2 in radiological imaging, SPECT and PET, and also for its potential role in targeted MRI.

References

  1. Khawli LA, Biela BH, Hu PS, Epstein AL: Stable, genetically engineered F(ab')(2) fragments of chimeric TNT-3 expressed in mammalian cells. Hybrid Hybridomics 2002, 21: 11–8. 10.1089/15368590252917593

    Article  CAS  PubMed  Google Scholar 

  2. Britton KE: The development of new radiopharmaceuticals. Eur J Nucl Med 1990, 16: 373–85. 10.1007/BF00842796

    Article  CAS  PubMed  Google Scholar 

  3. Goel A, Baranowska-Kortylewicz J, Hinrichs SH, Wisecarver J, Pavlinkova G, Augustine S, et al.: Tc-99m-labeled divalent and tetravalent CC49 single-chain Fv's: Novel imaging agents for rapid in vivo localization of human colon carcinoma. J Nucl Med 2001, 42: 1519–27.

    CAS  PubMed  Google Scholar 

  4. Jain RK: Transport of Molecules in the Tumor Interstitium - A Review. Cancer Res 1987, 47: 3039–51.

    CAS  PubMed  Google Scholar 

  5. Milenic DE, Detrick B, Reynolds JC, Colcher D: Characterization of primate antibody responses to administered murine monoclonal immunoglobulin. Int J Biol Markers 1990, 5: 177–87.

    CAS  PubMed  Google Scholar 

  6. Primus FJ, Bennett SJ, Kim EE, Deland FH, Zahn MC, Goldenberg DM: Circulating Immune-Complexes in Cancer Patients Receiving Goat Radiolocalizing Antibodies to Carcinoembryonic Antigen. Cancer Res 1980, 40: 497–501.

    CAS  PubMed  Google Scholar 

  7. Yokota T, Milenic DE, Whitlow M, Schlom J: Rapid Tumor Penetration of a Single-Chain Fv and Comparison with other Immunoglobulin Forms. Cancer Res 1992, 52: 3402–8.

    CAS  PubMed  Google Scholar 

  8. Nisonoff A, Wissler FC, Lipman LN, Woernley DL: Separation of Univalent Fragments from the Bivalent Rabbit Antibody Molecule by Reduction of Disulfide Bonds. Arch Biochem Biophys 1960, 89: 230–44. 10.1016/0003-9861(60)90049-7

    Article  CAS  PubMed  Google Scholar 

  9. Hasemann CA, Capra JD: Immunoglobulins: Structure and Function. In Fundamental Immunology. Second edition. Edited by: Paul WE. New York: Raven Press; 1989:209–33.

    Google Scholar 

  10. Milenic DE, Esteban JM, Colcher D: Comparison of methods for the generation of immunoreactive fragments of a monoclonal antibody (B72.3) reactive with human carcinomas. Journal of Immunological Methods 1989, 120: 71–83. 10.1016/0022-1759(89)90291-3

    Article  CAS  PubMed  Google Scholar 

  11. Milenic DE: Radioimmunotherapy: Designer molecules to potentiate effective therapy. Seminars in Radiation Oncology 2000, 10: 139–55. 10.1016/S1053-4296(00)80051-X

    Article  CAS  PubMed  Google Scholar 

  12. Colcher D, Zalutsky M, Kaplan W, Kufe D, Austin F, Schlom J: Radiolocalization of Human Mammary-Tumors in Athymic Mice by a Monoclonal-Antibody. Cancer Res 1983, 43: 736–42.

    CAS  PubMed  Google Scholar 

  13. Milenic DE, Yokota T, Filpula DR, Finkelman MAJ, Dodd SW, Wood JF, et al.: Construction, Binding Properties, Metabolism, and Tumor Targeting of a Single-Chain Fv Derived from the Pancarcinoma Monoclonal Antibody CC49. Cancer Res 1991, 51: 6363–71.

    CAS  PubMed  Google Scholar 

  14. Wahl RL, Parker CW, Philpott GW: Improved Radioimaging and Tumor Localization with Monoclonal F(ab')2. J Nucl Med 1983, 24: 316–25.

    CAS  PubMed  Google Scholar 

  15. Covell DG, Barbet J, Holton OD, Black CDV, Parker RJ, Weinstein JN: Pharmacokinetics of Monoclonal Immunoglobulin G1, F(ab')2, and Fab' in Mice. Cancer Res 1986, 46: 3969–78.

    CAS  PubMed  Google Scholar 

  16. Wu AM: Antibodies and Antimatter: The Resurgence of Immuno-PET. J Nucl Med 2009, 50: 2–5.

    Article  CAS  PubMed  Google Scholar 

  17. Yokota T, Milenic DE, Whitlow M, Wood JF, Hubert SL, Schlom J: Microautoradiographic Analysis of the Normal Organ Distribution of Radioiodinated Single-Chain Fv and other Immunoglobulin Forms. Cancer Res 1993, 53: 3776–83.

    CAS  PubMed  Google Scholar 

  18. Boskovitz A, Akabani GH, Pegram CN, Bigner DD, Zalutsky MR: Human/murine chimeric 8 1C6 F(ab ')(2) fragment: preclinical evaluation of a potential construct for the targeted radiotherapy of malignant glioma. Nuclear Medicine and Biology 2004, 31: 345–55. 10.1016/j.nucmedbio.2003.10.008

    Article  CAS  PubMed  Google Scholar 

  19. Delaloye B, Bischof-Delaloye A, Buchegger F, von Fliedner V, Grob JP, Volant JC, et al.: Detection of colorectal-carcinoma by emission-computerized tomography after injection of I-123 labeled Fab or F(ab')2 fragments from monoclonal anti-carcinoembryonic antigen antibodies. J Clin Invest 1986, 77: 301–11. 10.1172/JCI112291

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  20. Elgqvist J, Andersson H, Jensen H, Kahu H, Lindegren S, Warnhammar E, et al.: Repeated Intraperitoneal alpha-Radioimmunotherapy of Ovarian Cancer in Mice. J Oncol 2010, 2010: 394913.

    Article  PubMed Central  PubMed  Google Scholar 

  21. Yang XD, Jia XC, Corvalan JRF, Wang P, Davis CG: Development of ABX-EGF, a fully human anti-EGF receptor monoclonal antibody, for cancer therapy. Crit Rev Oncol/Hematol 2001, 38: 17–23. 10.1016/S1040-8428(00)00134-7

    Article  CAS  Google Scholar 

  22. Giusti RM, Shastri KA, Cohen MH, Keegan P, Pazdur R: FDA drug approval summary: Panitumumab (Vectibix (TM)). Oncologist 2007, 12: 577–83. 10.1634/theoncologist.12-5-577

    Article  CAS  PubMed  Google Scholar 

  23. Rowinsky E, Schwartz G, Dutcher J, Vogelzang N, Gollob J, Thompson J, et al.: ABX-EGF, a fully human anti-epidermal growth factor receptor (EGFr) monoclonal antibody: phase II clinical trial in renal cell cancer (RCC). Eur J Cancer 2002, 38: 178.

    Google Scholar 

  24. Liu Z, Liu Y, Jia B, Zhao H, Jin X, Li F, et al.: Epidermal growth factor receptor-targeted radioimmunotherapy of human head and neck cancer xenografts using 90Y-labeled fully human antibody panitumumab. Mol Cancer Ther 2010, 9: 2297–308. 10.1158/1535-7163.MCT-10-0444

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  25. Ray GL, Baidoo KE, Wong KJ, Williams M, Garmestani K, Brechbiel MW, et al.: Preclinical evaluation of a monoclonal antibody targeting the epidermal growth factor receptor as a radioimmunodiagnostic and radioimmunotherapeutic agent. Br J Pharmacol 2009, 157: 1541–8. 10.1111/j.1476-5381.2009.00327.x

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  26. Nayak TK, Garmestani K, Milenic DE, Baidoo KE, Brechbiel MW: HER1-Targeted Y-Panitumumab Possesses Superior Targeting Characteristics than Y-Cetuximab for PET Imaging of Human Malignant Mesothelioma Tumors Xenografts. PLoS One 2011, 6: e18198. 10.1371/journal.pone.0018198

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  27. Nayak TK, Regino CAS, Wong KJ, Milenic DE, Garmestani K, Baidoo KE, et al.: PET imaging of HER1-expressing xenografts in mice with Y-86-CHX-A"-DTPA-cetuximab. European Journal of Nuclear Medicine and Molecular Imaging 2010, 37: 1368–76. 10.1007/s00259-009-1370-z

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  28. Lowry OH, Rosebrough NJ, Farr AL, Randall RJ: Protein Measurement with the Folin Phenol Reagent. Journal of Biological Chemistry 1951, 193: 265–75.

    CAS  PubMed  Google Scholar 

  29. Milenic DE, Wong KJ, Baidoo KE, Ray GL, Garmestani K, Williams M, et al.: Cetuximab: Preclinical Evaluation of a Monoclonal Antibody Targeting EGFR for Radioimmunodiagnostic and Radioimmunotherapeutic Applications. Cancer Biotherapy and Radiopharmaceuticals 2008, 23: 619–31. 10.1089/cbr.2008.0493

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  30. Wu C, Kobayashi H, Sun B, Yoo TM, Paik CH, Gansow OA, et al.: Stereochemical influence on the stability of radio-metal complexes in vivo . Synthesis and evaluation of the four stereoisomers of 2-(p-nitrobenzyl)-trans-CyDTPA. Bioorganic & Medicinal Chemistry 1997, 5: 1925–34. 10.1016/S0968-0896(97)00130-2

    Article  CAS  Google Scholar 

  31. Pippin CG, Parker TA, McMurry TJ, Brechbiel MW: Spectrophotometric method for determination of a bifunctional DTPA ligand in DTPA monoclonal-antibody conjugates. Bioconjugate Chem 1992, 3: 342–5. 10.1021/bc00016a014

    Article  CAS  Google Scholar 

  32. Garmestani K, Milenic DE, Plascjak PS, Brechbiel MW: A new and convenient method for purification of Y-86 using a Sr(II) selective resin and comparison of biodistribution of Y-86 and In-111 labeled Herceptin (TM). Nuclear Medicine and Biology 2002, 29: 599–606. 10.1016/S0969-8051(02)00322-0

    Article  CAS  PubMed  Google Scholar 

  33. Fraker PJ, Speck JC Jr: Protein and cell membrane iodinations with a sparingly soluble chloroamide, 1,3,4,6-tetrachloro-3a,6a-diphrenylglycoluril. Biochem Biophys Res Commun 1978, 80: 849–57. 10.1016/0006-291X(78)91322-0

    Article  CAS  PubMed  Google Scholar 

  34. Xu H, Baidoo K, Gunn AJ, Boswell CA, Milenic DE, Choyke PL, et al.: Design, synthesis, and characterization of a dual modality positron emission tomography and fluorescence Imaging agent for monoclonal antibody tumor-targeted imaging. Journal of Medicinal Chemistry 2007, 50: 4759–65. 10.1021/jm070657w

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  35. Xi W, Seidel J, Kakareka JW, Pohida TJ, Milenic DE, Proffitt J, et al.: MONICA: a compact, portable dual gamma camera system for mouse whole-body imaging. Nuclear Medicine and Biology 2010, 37: 245–53. 10.1016/j.nucmedbio.2009.12.003

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  36. Nayak TK, Garmestani K, Baidoo KE, Milenic DE, Brechbiel MW: Preparation, Biological Evaluation, and Pharmacokinetics of the Human Anti-HER1 Monoclonal Antibody Panitumumab Labeled with Y-86 for Quantitative PET of Carcinoma. J Nucl Med 2010, 51: 942–50. 10.2967/jnumed.109.071290

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  37. Smith-Jones PM, Solit DB, Akhurst T, Afronze F, Rosen N, Larson SM: Imaging the pharmacodynamics of HER2 degradation in response to Hsp90 inhibitors. Nat Biotechnol 2004, 22: 701–6. 10.1038/nbt968

    Article  CAS  PubMed  Google Scholar 

  38. Tabrizi MA, Tseng CML, Roskos LK: Elimination mechanisms of therapeutic monoclonal antibodies. Drug Discov Today 2006, 11: 81–8. 10.1016/S1359-6446(05)03638-X

    Article  CAS  PubMed  Google Scholar 

  39. Olafsen T, Wu AM: Antibody Vectors for Imaging. Semin Nucl Med 2010, 40: 167–81. 10.1053/j.semnuclmed.2009.12.005

    Article  PubMed Central  PubMed  Google Scholar 

  40. Tolmachev V: Imaging of HER-2 Overexpression in Tumors for Guiding Therapy. Curr Pharm Design 2008, 14: 2999–3019. 10.2174/138161208786404290

    Article  CAS  Google Scholar 

  41. Milenic D, Garmestani K, Dadachova E, Chappell L, Albert P, Hill D, et al.: Radioimmunotherapy of human colon carcinoma xenografts using a 213Bi-labeled domain-deleted humanized monoclonal antibody. Cancer Biother Radiopharm 2004, 19: 135–47. 10.1089/108497804323071904

    Article  CAS  PubMed  Google Scholar 

  42. Milenic DE, Garmestani K, Chappell LL, Dadachova E, Yordanov A, Ma DS, et al.: In vivo comparison of macrocyclic and acyclic ligands for radiolabeling of monoclonal antibodies with Lu-177 for radioimmunotherapeutic applications. Nuclear Medicine and Biology 2002, 29: 431–42. 10.1016/S0969-8051(02)00294-9

    Article  CAS  PubMed  Google Scholar 

  43. Milenic DE, Roselli M, Mirzadeh S, Pippin CG, Gansow OA, Colcher D, et al.: In vivo evaluation of bismuth-labeled monoclonal antibody comparing DTPA-derived bifunctional chelates. Cancer Biotherapy and Radiopharmaceuticals 2001, 16: 133–46. 10.1089/108497801300189227

    Article  CAS  PubMed  Google Scholar 

  44. Buchegger F, Pelegrin A, Hardman N, Heusser C, Lukas J, Dolci W, et al.: Different behavior of mouse-human chimeric antibody F(ab')2 fragments of IgG1, IgG2, and IgG4 sub-class in vivo . Int J Cancer 1992, 50: 416–22. 10.1002/ijc.2910500316

    Article  CAS  PubMed  Google Scholar 

  45. Burvenich IJG, Schoonooghe S, Blanckaert P, Bacher K, Vervoort L, Coene E, et al.: Biodistribution and planar gamma camera imaging of I-123- and I-131-labeled F(ab ')(2) and Fab fragments of monoclonal antibody 14C5 in nude mice bearing an A549 lung tumor. Nuclear Medicine and Biology 2007, 34: 257–65. 10.1016/j.nucmedbio.2006.12.006

    Article  CAS  PubMed  Google Scholar 

  46. Ober RJ, Radu CG, Ghetie V, Ward ES: Differences in promiscuity for antibody-FcRn interactions across species: implications for therapeutic antibodies. Int Immunol 2001, 13: 1551–9. 10.1093/intimm/13.12.1551

    Article  CAS  PubMed  Google Scholar 

  47. Grunberg J, Novak-Hofer I, Honer M, Zimmermann K, Knogler K, Blauenstein P, et al.: In vivo evaluation of Lu-177- and Cu-67/64-labelled recombinant fragments of antibody chCE7 for radioimmunotherapy and PET imaging of L1-CAM-positive tumors. Clinical Cancer Research 2005, 11: 5112–20. 10.1158/1078-0432.CCR-05-0227

    Article  PubMed  Google Scholar 

  48. Niu G, Li Z, Xie J, Le QT, Chen X: PET of EGFR antibody distribution in head and neck squamous cell carcinoma models. J Nucl Med 2009, 50: 1116–23. 10.2967/jnumed.109.061820

    Article  CAS  PubMed  Google Scholar 

  49. Villaraza AJ, Milenic DE, Brechbiel MW: Improved Speciation Characteristics of PEGylated Indocyanine Green-Labeled Panitumumab: Revisiting the Solution and Spectroscopic Properties of a Near-Infrared Emitting anti-HER1 Antibody for Optical Imaging of Cancer. Bioconjug Chem 2010,21(12):2305–12. 10.1021/bc100336b

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  50. Divgi CR, Welt S, Kris M, Real FX, Yeh SD, Gralla R, et al.: Phase I and imaging trial of indium 111-labeled anti-epidermal growth factor receptor monoclonal antibody 225 in patients with squamous cell lung carcinoma. J Natl Cancer Inst 1991, 83: 97–104. 10.1093/jnci/83.2.97

    Article  CAS  PubMed  Google Scholar 

  51. Schechter NR, Wendt RE, Yang DJ, Azhdarinia A, Erwin WD, Stachowiak AM, et al.: Radiation dosimetry of 99mTc-labeled C225 in patients with squamous cell carcinoma of the head and neck. J Nucl Med 2004, 45: 1683–7.

    CAS  PubMed  Google Scholar 

  52. Adams GP, Schier R, McCall AM, Simmons HH, Horak EM, Alpaugh RK, et al.: High affinity restricts the localization and tumor penetration of single-chain Fv antibody molecules. Cancer Res 2001, 61: 4750–5.

    CAS  PubMed  Google Scholar 

  53. Adams GP, Tai MS, McCartney JE, Marks JD, Stafford WF, Houston LL, et al.: Avidity-mediated enhancement of in vivo tumor targeting by single-chain Fv dimers. Clin Cancer Res 2006, 12: 1599–605. 10.1158/1078-0432.CCR-05-2217

    Article  CAS  PubMed  Google Scholar 

  54. McCabe KE, Wu AM: Positive progress in immunoPET--not just a coincidence. Cancer Biother Radiopharm 2010, 25: 253–61. 10.1089/cbr.2010.0776

    Article  CAS  PubMed Central  PubMed  Google Scholar 

Download references

Acknowledgements

This research was supported by the Intramural Research Program of the NIH, National Cancer Institute, Center for Cancer Research. The authors are grateful for the support and encouragement so kindly provided by Mr. Elwood P. Dowd during the course of these studies.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Diane E Milenic.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

KJW performed the in vitro and in vivo studies. KEB and KG carried out radiolabelings. TN performed PET imaging and analysis. MWB synthesized the chelate and participated in the design of the studies. DEM conceived of and coordinated the studies and assisted with the in vivo experiments. All authors assisted in the drafting of the manuscript, the final version of which has been read and approved by all of the authors.

Authors’ original submitted files for images

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 2.0 International License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Wong, K.J., Baidoo, K.E., Nayak, T.K. et al. In vitro and in vivo pre-clinical analysis of a F(ab')2 fragment of panitumumab for molecular imaging and therapy of HER1-positive cancers. EJNMMI Res 1, 1 (2011). https://doi.org/10.1186/2191-219X-1-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/2191-219X-1-1

Keywords