Skip to main content

Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition

Abstract

Background

The RTOG 94-13 trial has provided evidence that patients with high risk prostate cancer benefit from an additional radiotherapy to the pelvic nodes combined with concomitant hormonal ablation. Since lymphatic drainage of the prostate is highly variable, the optimal target volume definition for the pelvic lymph nodes is problematic. To overcome this limitation, we tested the feasibility of an intensity modulated radiation therapy (IMRT) protocol, taking under consideration the individual pelvic sentinel node drainage pattern by SPECT functional imaging.

Methods

Patients with high risk prostate cancer were included. Sentinel nodes (SN) were localised 1.5–3 hours after injection of 250 MBq 99mTc-Nanocoll using a double-headed gamma camera with an integrated X-Ray device. All sentinel node localisations were included into the pelvic clinical target volume (CTV). Dose prescriptions were 50.4 Gy (5 × 1.8 Gy / week) to the pelvis and 70.0 Gy (5 × 2.0 Gy / week) to the prostate including the base of seminal vesicles or whole seminal vesicles. Patients were treated with IMRT. Furthermore a theoretical comparison between IMRT and a three-dimensional conformal technique was performed.

Results

Since 08/2003 6 patients were treated with this protocol. All patients had detectable sentinel lymph nodes (total 29). 4 of 6 patients showed sentinel node localisations (total 10), that would not have been treated adequately with CT-based planning ('geographical miss') only. The most common localisation for a probable geographical miss was the perirectal area. The comparison between dose-volume-histograms of IMRT- and conventional CT-planning demonstrated clear superiority of IMRT when all sentinel lymph nodes were included. IMRT allowed a significantly better sparing of normal tissue and reduced volumes of small bowel, large bowel and rectum irradiated with critical doses. No gastrointestinal or genitourinary acute toxicity Grade 3 or 4 (RTOG) occurred.

Conclusion

IMRT based on sentinel lymph node identification is feasible and reduces the probability of a geographical miss. Furthermore, IMRT allows a pronounced sparing of normal tissue irradiation. Thus, the chosen approach will help to increase the curative potential of radiotherapy in high risk prostate cancer patients.

Peer Review reports

Background

Treatment strategies for localised prostate cancer have to address issues of local control, prevention of distant spread and treatment of microscopic locoregional spread. It has been shown that local control is critically interrelated with the prevention of distant spread, since late metastases occur in patients with local failure [1]. In order to increase the efficacy of radiotherapy, many recent trials suggest the strategy of dose escalation [2–19].

Particularly the availability of three-dimensional conformal radiation treatment (3D-CRT) and further development of intensity modulated radiation treatment (IMRT) allow the application of higher radiation doses to the prostate without increased toxicities to normal tissues. The available data suggest that prostate cancer especially in patients with intermediate risk profile benefit from dose escalation (reviewed in [20]). On the other hand, patients with a high risk profile do not show such a steep dose response relationship because of the risks of loco- regional and ultimately systemic spread.

A further approach to increase local control rates and the rates of biochemical disease control is the combination of radiation with anti-hormonal treatment. Several recently published results of larger trials [21–23] could demonstrate a clear benefit from a combined treatment in patients with locally advanced prostate cancer. Most of these trials have employed radiation portals covering the locoregional lymphatic drainage in addition to the prostate using a standardised anatomical definition.

Of special importance in this regard is the four-armed RTOG 94-13 trial comparing neoadjuvant vs. adjuvant anti-hormonal treatment and radiotherapy of the whole pelvis vs. the prostate only. Patients with an estimated risk of pelvic lymph node involvement > 15% had a significant benefit when treated with neoadjuvant and concurrent hormonal ablation in combination with radiotherapy to the prostate (70.2 Gy) and the pelvic lymph nodes (50.4 Gy). The most significant difference in 4-year progression free survival rates was observed between the groups of whole pelvis (61%) and prostate only (45%) irradiated patients when treated with neoadjuvant and concurrent hormonal ablation [23].

Thus, besides dose escalation strategies or combination with anti-hormonal treatments, adjuvant coverage of the pelvic lymph nodes may be of importance for an optimised tumour control.

Currently, the definition of an adjuvant pelvic target volume is derived from non-individualised anatomical lymphatic drainage patterns. Radiation planning and therapy is mostly performed as 3D-CT based treatment along the ICRU 50 guidelines.

However, the lymphatic drainage from the prostate is highly variable. In this regard, data on sentinel lymph nodes analysis in prostate cancer are of key importance. To optimise lymphadenectomy techniques, Wawroschek et al. [24, 25] and Weckermann et al. [26] tested the sentinel lymph node (SN) identification with prostate lymphoscintigraphy and radio-guided surgery in large cohort. The results demonstrated that sentinel node identification in prostate cancer is feasible with a sensitivity between 93 and 96% and enables higher detection rates of micrometastases. However, the authors noted a strong individual variability of the lymphatic drainage in their patient cohort. Interestingly, only 44.2% of detectable cases with positive nodes were found in the obturator fossa, the most common area for a limited lymphadenectomy. These findings correspond to surgical data of 103 patients after extended lymphadenectomy [27]. In the latter, the most common areas of lymph node metastases were the external and internal iliac, followed by obturator, common iliac and presacral regions.

Considering these results, the definition of standardised target volumes covering the pelvic lymph nodes is associated with several problems. Trying to cover all possible areas of lymphatic drainage increases the probability of toxicities. In contrast, by limiting the target volume to the most commonly involved lymph node areas increases the risk of incomplete target volume coverage.

To overcome the limitations described above, we started an IMRT trial for high risk prostate cancer with a target volume definition based on the average distribution of positive lymph nodes in prostate cancer patients complemented by sentinel node functional imaging with SPECT.

Methods

Patients

Patients with histologically proven high risk prostate cancer, but cN0 cM0 stage, were included after providing informed consent. High risk profile was defined as T3 or T4 stage (all) or PSA > 20 ng/mL (all) or PSA 10 – 20 ng/mL with Gleason Scores = 7. Besides PSA level, rectal-digital examination and biopsy, the pre-therapeutic staging included a computed tomographic and/or magnetic resonance imaging of the abdomen and pelvis, an ultrasound of the prostate, a total body bone scan and X-ray of the chest. The clinical TNM stage was determined based on these staging results.

Localisation of sentinel nodes

To permit a 3D-localisation of the sentinel nodes, transmission and emission scans were acquired using a double-headed gamma camera with an integrated X-Ray device (Millennium VG & Hawkeye®, GE Medical Systems Europe, Buc Cedex, France) 1.5–3 hours after transrectal intraprostatic injection of 250 MBq 99mTc-Nanocoll. A single ultrasound-guided central application was performed per prostate lobe. After the anatomical-functional image fusion, the scans were analysed with respect to 3D-localisation and number of sentinel nodes. The sentinel nodes were three-dimensionally located by an experienced member of the nuclear medicine department (K.E., R.B.). For a systematic topographic evaluation of lymph node localisation, we used the Cross-sectional Nodal Atlas published by Martinez-Monge 1999 [28](figure 1).

Figure 1
figure 1

Terms and definitions of nodal groups according to Martinez-Monge et al. (1999). The obturator and hypogastric lymph nodes include periprostatic and seminal vesicle lymphatic plexus, parts of perivesical and the perirectal lymphatic plexus nearby the prostate, the ventrocranial parts of the internal pudendal and inferior rectal nodes

Treatment planning

Intensity modulated radiotherapy planning was based on three CT scans of the pelvis in supine (2 patients) and prone (4 patients, using a belly board) position at 3 mm slice spacing from two cm below the ischeal tuberosities to the L 4/5 interspace. For a comfortable bladder filling, patients were instructed to avoid urination during the last 45 minutes before the procedure. The CT datasets were transferred to the Pinnacle® treatment planning system (Philips Medical Systems, DA Best, Netherlands) for segmentation. Clinical target volume (CTV) and organs at risk (OAR) were outlined in each CT image. OAR included rectum, colon/sigmoid, small bowel, bladder and hips. Image fusion was done by adjusting the bone structures of the pelvis. Finally, a single enclosing contour was derived from the three outlined CTV/OAR. For the resulting planning target volume (PTV) the enclosing CTV contour was expanded with a 3D safety margin of 7 mm.

Since two different risk areas are treated simultaneously, the term first- and second-order CTV will be used in the following. The first-order CTV included the prostate and the base of seminal vesicles. In cases of T stage ≥ 3 or an estimated risk for an involvement of the seminal vesicles > 15% (Partin nomograms) [29], seminal vesicles were included into the boost volume.

The second-order CTV included the first order CTV and routinely the obturator and hypogastric lymph nodes (following the nomenclature introduced by Martinez-Monge: Periprostatic and seminal vesicle lymphatic plexus, the parts of the perivesical and the perirectal lymphatic plexus nearby the prostate, the ventrocranial parts of the internal pudendal and inferior rectal nodes), the internal and external iliac lymph nodes (from the bifurcation of the common iliac lymph artery at the level of the upper sacroiliac joints, to the crossing point of the external iliac artery and the inguinal ligament) and the sacral nodes anterior the first and second sacral segment. In addition to this regular second-order CTV all detected sentinel node localisations were outlined separately and involved into the IMRT target volume definition.

Dose prescriptions were 50.4 Gy (5 × 1.8 Gy / week) to the pelvic nodes and 70.0 Gy (5 × 2.0 Gy / week) to the prostate and the base of seminal vesicles or whole seminal vesicles by an integrated boost planning. After forward decision regarding gantry angles, an inverse treatment planning was carried out by the Hyperion® software package (University of Tübingen, Germany) [30]. Based on a class solution, six IMRT fields were used for the initial 28 fractions and 5 fields for the ensuing 7 fractions. The following normal tissue constraints were chosen: Rectum, 58–65 Gy serial dose constraint; Bladder, 50–56 Gy serial dose constraint; Small Bowel, 20–22 Gy mean dose constraint and 50–54 Gy maximum dose constraint. The dosimetrics were calculated by Monte Carlo dose calculation.

Plans were produced for a 15 MV linear accelerator (Elekta Oncology Systems®, Crawley, UK) for delivery with a multileaf collimator system using a step and shoot technique. The IMRT plans were compared with 3D-CRT plans (four-field-technique, gantry angles 0°, 90°, 180°, 270°) using the Pinnacle® treatment planning system based on the identical CTV. Dose volume histograms (DVH) were calculated for each plan. The PTV dose ranges were calculated with the minimum PTV dose defined as dose received by ≥ 99% of the PTV and the maximum dose defined as the dose received by = 1% of the PTV. The volume percentages of small bowel, large bowel (sigmoid/colon), rectum and bladder irradiated with 63 Gy, 56 Gy, 35 Gy, 14 Gy were recorded for each technique. The DVH comparisons were done for each patient using the summarised plan.

Verification

Prior to each radiation fraction, the isocenter was verified by portal imaging from 0° and 90° gantry angle. An error of more than 2 mm was corrected. The administered monitor units needed for one daily verification were included in the initial dose calculation.

Analysis of toxicity

Acute gastrointestinal, genitourinary and skin toxicities (RTOG criteria) were documented by standard forms weekly during RT and at least after three months.

Results

Patients

Since August 2003, six patients with T1c-3b high risk prostate cancers (figure 2) were evaluated. No patient had undergone a staging lymphadenectomy of the pelvic lymph nodes before. All patients had normal pre-therapeutic diagnostic findings with a clinical N0 M0 stage. All patients received neoadjuvant and concurrent hormonal ablation, which was recommended to continue adjuvantly for three years. In all cases neoadjuvant treatment had been started before the first visit in hospital.

Figure 2
figure 2

Patients characteristics.

Localisation of sentinel nodes

The transrectal intraprostatic injection of 99mTc-Nanocoll was performed in all patients without any complications. After radioisotope injection and image fusion, each patient had detectable sentinel lymph nodes. The number per patient ranged from two to nine detected lymph nodes. Altogether, a total of twenty-nine lymph nodes could be identified for all six patients (figure 3). The most common localisations of identified lymph nodes were external iliac (9), followed by internal iliac (6) and perirectal lymphatic plexus (6). Further localisations were common iliac (2), sacral (2), internal pudendal (1), seminal vesicle lymphatic plexus (1), superior rectal (1) and left paraaortic (1).

Figure 3
figure 3

Number and localisation of sentinel nodes. Localisation of lymph node areas not covered by a standard target volume definition plan are shaded grey (geographical misses).

IMRT treatment planning

The first two patients were planned and treated in supine position. Since prone position in combination with a belly board allowed easier sparing of small bowel [31], we changed to the prone position for the following four patients. All detected sentinel lymph nodes could be included into the second-order CTV. The IMRT plans carried out by Hyperion® produced an average of 55 segments (total/fraction) and 495 Monitor Units (total/fraction) for the first 28 fractions and an average of 35 segments (total/fraction) and 346 Monitor Units (total/fraction) for the ensuing 7 fractions. Thus, fast delivery and practical treatment times were possible. A class solution delivered stable and comparable results for all patients. Detailed characteristics of IMRT technique are shown in figure 4.

Figure 4
figure 4

IMRT planning results: 28 fractions including pelvic nodes with integrated boost (upper table) and 7 fractions without pelvic nodes (lower table). MU total / fraction adds up MU's per field and fraction (rounded), including additionally 3 MU's necessary for daily verification (not included in 'MU's per field and fraction)

The minimum PTV dose ranged from 40 to 48.1 Gy for the second-order PTV, including the pelvic nodes. The maximum PTV dose ranged from 72.4 to 74.2 Gy for the prostate gland (figure 5). The critical dose of 60 Gy to the whole bladder volume was not reached in any patient.

Figure 5
figure 5

PTV dose ranges 3D-CRT vs. IMRT. Minimum PTV dose defined as the dose received by = 99% of the PTV, maximum PTV dose defined as the dose received by = 1% of the PTV. * Dose contribution by the boost RT.

A critical dose to the small bowel of 50 Gy was reached in two patients in very small volumes (0.5% and 1%, respectively). Large bowel doses ≥ 50 Gy were seen in very limited volumes (0%, 2.7%, 2.7%, 4.1%, 6.6% and 13.6%). The single event of a higher dose volume of 13.6% was seen in one patient (No. 5) with an adherent sigmoid loop in close vicinity to the prostate. Rectum volumes irradiated with more than 56 Gy ranged from 16.3% to 52.1%, with more than 63 Gy from 9.5% to 36.6%. The detailed analysis of irradiated organs at risk volume percentages is given in table 6.

Influence of sentinel node localisation on target volume definition

4 of 6 patients had sentinel node localisations (total 10 of 29 sentinel lymph nodes) that would not have been treated adequately with conventional target volume definition ('geographical miss'). Thus, the target volume definition was modified by sentinel lymph node information in 4 of 6 patients. The results of numbers and localisations of sentinel lymph nodes are shown in table 3, grey shaded fields show the number and localisation of geographical misses.

The lymph node area associated with the highest probability of a 'geographical miss' was the perirectal lymph node group with 6 identified sentinel nodes partly localised nearby the dorsal circumference of the rectal wall. Single sentinel nodes were found in the internal pudendal, sacral, superior rectal and left paraaortic region. None of those was covered by standardised planning target volumes. The identified sentinel lymph node in the left paraaortic area was localised at the L4/5 interspace. Because the CT scans showed a lymph node of 11 mm diameter at this localisation, we decided to include it.

DVH comparison between IMRT and 3D-CRT treatment planning

The patients were treated using IMRT technique (figure 4). Additionally, a 3D-conformal treatment planning with a four-field-technique (gantry angles 0°, 90°, 180°, 270°) was produced for each patient based on the identical CT datasets with the identical outlined CTV and OAR.

The comparison of minimum and maximum PTV doses between 3D-CRT and IMRT is shown in figure 5. IMRT minimum PTV dose ranged from 40 to 48.1 Gy, 3D-CRT minimum PTV dose from 47 to 49.3 Gy for the 2nd order PTV. IMRT minimum PTV dose ranged from 62.4 to 67 Gy, 3D-CRT minimum PTV dose from 67.4 to 68.9 Gy for the 1st order PTV. IMRT maximum PTV dose ranged from 72.4 to 74.2 Gy, 3D-CRT maximum PTV dose from 71.5 to 72.6 Gy for the 1st order PTV.

The DVH comparisons between IMRT and 3D-CRT in regard to small bowel, large bowel and rectum are shown in figure 6. Small bowel volumes irradiated with 14Gy and 35 Gy increased in four patients (in part very slightly) by using IMRT and decreased clearly in two patients with a volume reduction in more than 10%. With IMRT the critical dose to the small bowel of 50 Gy was seen in two patients with volumes of 0.5% and 1%, respectively, compared to 3D-CRT with five patients with volumes between 0 and 25.3%. Concerning the large bowel, IMRT similarly caused increased low dose irradiated volumes, but significant smaller irradiated volumes at the critical dose of 50 Gy. The most important difference was seen in the irradiated rectum volumes. All patients showed a clear benefit from IMRT with a clear decrease in volumes irradiated with 56 Gy and 63 Gy. As an example a dose distribution of a single patient are shown in figure 7.

Figure 6
figure 6

3D-CRT vs. IMRT. – DVH comparison of small bowel, large bowel and rectum. V63Gy, V56Gy, V50Gy, V35Gy, V14Gy denote the volume of a given organ (in %) irradiated with 63 Gy, 56 Gy, 50 Gy, 35 Gy, 14 Gy.

Figure 7
figure 7

Planning example: Upper left : Sentinel lymph nodes left internal iliac (2), right internal iliac (1), perirectal on an axial SPECT image (prone position). Upper middle: IMRT planning: sentinel node localisations and second order PTV are outlined (prone position). The 95% isodose curve is shaped green. Upper right : 3D-CRT planning (four-field-box): sentinel node localisations and second order PTV are outlined (prone position). The 95% isodose curve is shaped green. Lower left: Dose-volume-histogram IMRT. Lower right: Dose-volume-histogram 3D-CRT

Acute toxicities

All patients completed the radiotherapy course after seven weeks with a dose of 70.0 Gy without treatment interruption. During radiotherapy interval, genitourinary toxicity RTOG Grade 1 occurred in all six patients, four patients increased to a genitourinary toxicity RTOG Grade 2. Gastrointestinal toxicity RTOG Grade 1 was seen in all six patients, two patients showed a gastrointestinal toxicity RTOG Grade 2. No gastrointestinal or genitourinary acute toxicity Grade 3 or 4 was noted. There were no toxicities seen concerning the skin. All patients reported erectile dysfunction, since neoadjuvant hormonal ablation had been started. After three months, two patients reported slight genitourinary symptoms (RTOG Grade 1), one of them had a slightly increased defecation frequency corresponding to a gastrointestinal toxicity RTOG Grade 1. The other four patients did not show any toxicity after three months.

Discussion

Although being still controversial, several data suggest that an adjuvant coverage of the pelvic lymph nodes increases the likelihood of tumour control in patients with high risk prostate cancer. Whereas several older trials suggested that larger irradiation portals may not increase the treatment efficacy [32–41], recent randomised and nonrandomised studies could demonstrate a benefit of elective pelvic lymph node irradiation [21–23, 42–47].

Of special value is the randomised four-armed RTOG 94-13 trial, since it was designed to provide a final answer regarding the role of adjuvant lymph node coverage. It showed that high risk prostate cancer patients benefit from radiotherapy of the pelvic lymph nodes combined with neoadjuvant and concurrent hormonal ablation. A significant benefit was documented in terms of advanced 4-year progression free survival rates [23], but not for overall survival. Interestingly, there was no significant difference in toxicities between patients treated on any of the four arms that may be caused by improved treatment techniques in comparison to former studies. The role of pelvic node coverage is also underlined by the fact that the EORTC trial [21] randomised high risk and lymph node positive patients to receive concurrent and long term adjuvant hormonal ablation treatment or radiotherapy alone, which included 50 Gy to the pelvis and a 20 Gy boost to the prostate. A substantial benefit in terms of local control, disease specific survival and overall survival was noted for the group receiving anti-hormonal treatment. Regarding 5-year clinical disease-free survival rates of 74% and 40% (no hormonal ablation) respectively, it has to be assumed that combined treatment with anti-hormonal therapy and radiation of the pelvic lymph nodes improves outcome of high risk and lymph node positive patients. Comparable results were shown by the RTOG 92-02 trial (including patients with cT2c-4, PSA < 150 ng/mL) combining radiotherapy of the pelvic nodes and the prostate with anti-hormonal short vs. long term treatment. An overall survival advantage was seen in a subset analysis of patients with Gleason Scores 8 to 10 (81% vs. 71%) [22].

Regarding efficacy, available data make it highly likely that the subgroup of patients with high risk of pelvic lymph node involvement will benefit from this treatment. Thus, it can be assumed that any further improvement in staging and irradiation techniques will help to optimise outcome. The sentinel concept was mainly developed for an optimised surgical lymph node identification and dissection in patients with malignant melanoma [48]. This concept can also be perfectly applied to breast cancer [49], head & neck cancer [50] and probably also to prostate cancer [24, 25]. Key work was done by Wawroschek and Harzmann providing evidence that 99mTc-Nanocoll based sentinel node identification is highly sensitive and specific. Similar results were obtained by us in a smaller cohort [51]. Therefore, sentinel image data may be used for radiation treatment planning.

The discussion on a potentially increased toxicity of larger irradiation portals was mainly supported by results from older studies, which were not based on modern CT planning. Thus, the favourable results from the RTOG 94-13 trial may in part be explained by optimised treatment techniques. Meanwhile, few clinical studies suggest superiority of IMRT when used for radiotherapy of the prostate alone [7]. However, even less data are available concerning an inclusion of the pelvic lymph nodes with IMRT. Nutting et al. [52] performed a theoretical trial in 10 patients and compared different IMRT treatment techniques among each other and to conventional 3D-CRT. The data provided in this study show eloquently that IMRT based irradiation protocols allow clear reduction of limiting normal tissue exposure. In a second paper from the same group, quality assurance aspects of clinical introduction comparing a step and shoot versus dynamic arch application were described. The authors concluded that the technique is feasible and neither of both application modi was superior [53]. Similarly, Mundt analysed the applicability of an IMRT based protocol for the treatment of pelvic lymph nodes in patients with gynaecological malignancies [54]. The authors conclude that IMRT based irradiation is associated with a diminished normal tissue toxicity profile and an optimised target coverage. However, in contrast to our work, both authors used anatomically based target volume definitions rather than an individualised sentinel lymph nodes based planning approach.

Our approach to combine sentinel data with IMRT addresses crucial aspects of target coverage and also toxicity. To reduce the likelihood of a 'geographical miss' we purposed the complete individualised coverage of lymphatic drainage using functional imaging. Possibly, individualised target volumes may cause increased toxicities. Not to mention, we observed a notable number of sentinel nodes nearby the dorsal rectal wall and their inclusion into the target volumes causes increased toxicities when a conventional four-field-technique is used (figure 8). Whereas the focus of 3D treatment planning is on target coverage, IMRT target coverage is compromised by the need of normal tissue sparing. Our own data hint at an optimal target volume coverage and showed a clear benefit in OAR sparing by using IMRT with low overall acute toxicities. Thus, IMRT is necessary to decrease toxicities resulting from individualised target volume definition.

Figure 8
figure 8

Axial CT slices of three example cases.

Conclusion

In order to optimise the balance between increased probability of side effects and improved target volume coverage, we tested a sentinel node based IMRT approach. Based on a limited number of patients the following conclusions can be drawn: Sentinel functional imaging optimised target volume definition for IMRT is clearly feasible with no obvious increase in acute toxicity and suitable for larger numbers of patients. The probability of a geographical miss in target volume definition might be reduced by an individualised target volume definition. However, larger series are necessary to verify the expected benefit in regard to efficacy and toxicities.

Abbreviations

3D-CRT:

Three-dimensional conformal radiotherapy

CT:

Computed tomography

CTV:

Clinical target volume

DVH:

Dose volume histogram

Gy:

Gray

ICRU:

International Commission on Radiation Units and Measurements

IMRT:

Intensity modulated radiotherapy

MBq:

mega Becquerel

MV:

mega Volt

ng/mL:

nanogram/millilitre

OAR:

Organ at risk

PSA:

Prostate specific antigen

PTV:

Planning target volume

RTOG:

Radiation Therapy Oncology Group

SN:

Sentinel node

SPECT:

Single Photon Emission Computed Tomography)

TNM TNM:

stage classification (tumour/nodal/metastases stage)

Tc:

Technetium

vs.:

versus

References

  1. Coen JJ, Zietman AL, Thakral H, Shipley WU: Radical radiation for localized prostate cancer: local persistence of disease results in a late wave of metastases. J Clin Oncol. 2002, 20: 3199-3205. 10.1200/JCO.2002.01.086.

    Article  PubMed  Google Scholar 

  2. Hanks GE, Hanlon AL, Schultheiss TE, Pinover WH, Movsas B, Epstein BE, Hunt MA: Dose escalation with 3D conformal treatment: five year outcomes, treatment optimization, and future directions. Int J Radiat Oncol Biol Phys. 1998, 41: 501-510. 10.1016/S0360-3016(98)00089-3.

    Article  CAS  PubMed  Google Scholar 

  3. Hanks GE, Hanlon AL, Pinover WH, Horwitz EM, Schultheiss TE: Survival advantage for prostate cancer patients treated with high-dose three-dimensional conformal radiotherapy. Cancer J Sci Am. 1999, 5: 152-158.

    CAS  PubMed  Google Scholar 

  4. Hanks GE, Hanlon AL, Epstein B, Horwitz EM: Dose response in prostate cancer with 8-12 years' follow-up. Int J Radiat Oncol Biol Phys. 2002, 54: 427-435. 10.1016/S0360-3016(02)02954-1.

    Article  PubMed  Google Scholar 

  5. Zelefsky MJ, Leibel SA, Gaudin PB, Kutcher GJ, Fleshner NE, Venkatramen ES, Reuter VE, Fair WR, Ling CC, Fuks Z: Dose escalation with three-dimensional conformal radiation therapy affects the outcome in prostate cancer. Int J Radiat Oncol Biol Phys. 1998, 41: 491-500. 10.1016/S0360-3016(98)00091-1.

    Article  CAS  PubMed  Google Scholar 

  6. Zelefsky MJ, Fuks Z, Hunt M, Lee HJ, Lombardi D, Ling CC, Reuter VE, Venkatraman ES, Leibel SA: High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer. J Urol. 2001, 166: 876-881. 10.1097/00005392-200109000-00017.

    Article  CAS  PubMed  Google Scholar 

  7. Zelefsky MJ, Fuks Z, Hunt M, Yamada Y, Marion C, Ling CC, Amols H, Venkatraman ES, Leibel SA: High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients. Int J Radiat Oncol Biol Phys. 2002, 53: 1111-1116. 10.1016/S0360-3016(02)02857-2.

    Article  PubMed  Google Scholar 

  8. Symon Z, Griffith KA, McLaughlin PW, Sullivan M, Sandler HM: Dose escalation for localized prostate cancer: substantial benefit observed with 3D conformal therapy. Int J Radiat Oncol Biol Phys. 2003, 57: 384-390. 10.1016/S0360-3016(03)00569-8.

    Article  PubMed  Google Scholar 

  9. Pollack A, Zagars GK, Smith LG, Lee JJ, von Eschenbach AC, Antolak JA, Starkschall G, Rosen I: Preliminary results of a randomized radiotherapy dose-escalation study comparing 70 Gy with 78 Gy for prostate cancer. J Clin Oncol. 2000, 18: 3904-3911.

    CAS  PubMed  Google Scholar 

  10. Pollack A, Zagars GK, Starkschall G, Antolak JA, Lee JJ, Huang E, von Eschenbach AC, Kuban DA, Rosen I: Prostate cancer radiation dose response: results of the M. D. Anderson phase III randomized trial. Int J Radiat Oncol Biol Phys. 2002, 53: 1097-1105. 10.1016/S0360-3016(02)02829-8.

    Article  PubMed  Google Scholar 

  11. Valicenti R, Lu J, Pilepich M, Asbell S, Grignon D: Survival advantage from higher-dose radiation therapy for clinically localized prostate cancer treated on the Radiation Therapy Oncology Group trials. J Clin Oncol. 2000, 18: 2740-2746.

    CAS  PubMed  Google Scholar 

  12. Pollack A, Smith LG, von Eschenbach AC: External beam radiotherapy dose response characteristics of 1127 men with prostate cancer treated in the PSA era. Int J Radiat Oncol Biol Phys. 2000, 48: 507-512. 10.1016/S0360-3016(00)00620-9.

    Article  CAS  PubMed  Google Scholar 

  13. Hanks GE, Hanlon AL, Pinover WH, Horwitz EM, Price RA, Schultheiss T: Dose selection for prostate cancer patients based on dose comparison and dose response studies. Int J Radiat Oncol Biol Phys. 2000, 46: 823-832. 10.1016/S0360-3016(99)00498-8.

    Article  CAS  PubMed  Google Scholar 

  14. Kuban DA, Thames HD, Levy LB, Horwitz EM, Kupelian PA, Martinez AA, Michalski JM, Pisansky TM, Sandler HM, Shipley WU, Zelefsky MJ, Zietman AL: Long-term multi-institutional analysis of stage T1-T2 prostate cancer treated with radiotherapy in the PSA era. Int J Radiat Oncol Biol Phys. 2003, 57: 915-928. 10.1016/S0360-3016(03)00632-1.

    Article  PubMed  Google Scholar 

  15. Pinover WH, Hanlon AL, Horwitz EM, Hanks GE: Defining the appropriate radiation dose for pretreatment PSA < or = 10 ng/mL prostate cancer. Int J Radiat Oncol Biol Phys. 2000, 47: 649-654. 10.1016/S0360-3016(00)00465-X.

    Article  CAS  PubMed  Google Scholar 

  16. Kupelian PA, Buchsbaum JC, Reddy CA, Klein EA: Radiation dose response in patients with favorable localized prostate cancer (Stage T1-T2, biopsy Gleason < or = 6, and pretreatment prostate-specific antigen < or = 10). Int J Radiat Oncol Biol Phys. 2001, 50: 621-625. 10.1016/S0360-3016(01)01466-3.

    Article  CAS  PubMed  Google Scholar 

  17. Fiveash JB, Hanks G, Roach M, Wang S, Vigneault E, McLaughlin PW, Sandler HM: 3D conformal radiation therapy (3DCRT) for high grade prostate cancer: a multi-institutional review. Int J Radiat Oncol Biol Phys. 2000, 47: 335-342. 10.1016/S0360-3016(00)00441-7.

    Article  CAS  PubMed  Google Scholar 

  18. Hurwitz MD, Schnieder L, Manola J, Beard CJ, Kaplan ID, D'Amico AV: Lack of radiation dose response for patients with low-risk clinically localized prostate cancer: a retrospective analysis. Int J Radiat Oncol Biol Phys. 2002, 53: 1106-1110. 10.1016/S0360-3016(02)02885-7.

    Article  PubMed  Google Scholar 

  19. Jani AB, Hand CM, Pelizzari CA, Roeske JC, Krauz L, Vijayakumar S: Biological-effective versus conventional dose volume histograms correlated with late genitourinary and gastrointestinal toxicity after external beam radiotherapy for prostate cancer: a matched pair analysis. BMC Cancer. 2003, 3: 16-10.1186/1471-2407-3-16.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Ganswindt U, Paulsen F, Anastasiadis AG, Stenzl A, Bamberg M, Belka C: 70 Gy or more: which dose for which prostate cancer?. J Cancer Res Clin Oncol. 2005

    Google Scholar 

  21. Bolla M, Collette L, Blank L, Warde P, Dubois JB, Mirimanoff RO, Storme G, Bernier J, Kuten A, Sternberg C, Mattelaer J, Lopez Torecilla J, Pfeffer JR, Lino Cutajar C, Zurlo A, Pierart M: Long-term results with immediate androgen suppression and external irradiation in patients with locally advanced prostate cancer (an EORTC study): a phase III randomised trial. Lancet. 2002, 360: 103-106. 10.1016/S0140-6736(02)09408-4.

    Article  CAS  PubMed  Google Scholar 

  22. Hanks GE, Pajak TF, Porter A, Grignon D, Brereton H, Venkatesan V, Horwitz EM, Lawton C, Rosenthal SA, Sandler HM, Shipley WU: Phase III trial of long-term adjuvant androgen deprivation after neoadjuvant hormonal cytoreduction and radiotherapy in locally advanced carcinoma of the prostate: the Radiation Therapy Oncology Group Protocol 92-02. J Clin Oncol. 2003, 21: 3972-3978. 10.1200/JCO.2003.11.023.

    Article  CAS  PubMed  Google Scholar 

  23. Roach M, DeSilvio M, Lawton C, Uhl V, Machtay M, Seider MJ, Rotman M, Jones C, Asbell SO, Valicenti RK, Han S, Thomas CRJ, Shipley WS: Phase III Trial Comparing Whole-Pelvic Versus Prostate-Only Radiotherapy and Neoadjuvant Versus Adjuvant Combined Androgen Suppression: Radiation Therapy Oncology Group 9413. J Clin Oncol. 2003, 21: 1904-1911. 10.1200/JCO.2003.05.004.

    Article  PubMed  Google Scholar 

  24. Wawroschek F, Wagner T, Hamm M, Weckermann D, Vogt H, Markl B, Gordijn R, Harzmann R: The influence of serial sections, immunohistochemistry, and extension of pelvic lymph node dissection on the lymph node status in clinically localized prostate cancer. Eur Urol. 2003, 43: 132-6; discussion 137.. 10.1016/S0302-2838(02)00450-5.

    Article  PubMed  Google Scholar 

  25. Wawroschek F, Vogt H, Wengenmair H, Weckermann D, Hamm M, Keil M, Graf G, Heidenreich P, Harzmann R: Prostate lymphoscintigraphy and radio-guided surgery for sentinel lymph node identification in prostate cancer. Technique and results of the first 350 cases. Urol Int. 2003, 70: 303-310. 10.1159/000070140.

    Article  PubMed  Google Scholar 

  26. Weckermann D, Wawroschek F, Harzmann R: Is there a need for pelvic lymph node dissection in low risk prostate cancer patients prior to definitive local therapy?. Eur Urol. 2005, 47: 45-50; discussion 50-1. 10.1016/j.eururo.2004.07.017.

    Article  PubMed  Google Scholar 

  27. Heidenreich A, Varga Z, Von Knobloch R: Extended pelvic lymphadenectomy in patients undergoing radical prostatectomy: high incidence of lymph node metastasis. J Urol. 2002, 167: 1681-1686. 10.1097/00005392-200204000-00023.

    Article  PubMed  Google Scholar 

  28. Martinez-Monge R, Fernandes PS, Gupta N, Gahbauer R: Cross-sectional nodal atlas: a tool for the definition of clinical target volumes in three-dimensional radiation therapy planning. Radiology. 1999, 211: 815-828.

    Article  CAS  PubMed  Google Scholar 

  29. Partin AW, Mangold LA, Lamm DM, Walsh PC, Epstein JI, Pearson JD: Contemporary update of prostate cancer staging nomograms (Partin Tables) for the new millennium. Urology. 2001, 58: 843-848. 10.1016/S0090-4295(01)01441-8.

    Article  CAS  PubMed  Google Scholar 

  30. Alber M, Nusslin F: Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery. Phys Med Biol. 2001, 46: 3229-3239. 10.1088/0031-9155/46/12/311.

    Article  CAS  PubMed  Google Scholar 

  31. Adli M, Mayr NA, Kaiser HS, Skwarchuk MW, Meeks SL, Mardirossian G, Paulino AC, Montebello JF, Gaston RC, Sorosky JI, Buatti JM: Does prone positioning reduce small bowel dose in pelvic radiation with intensity-modulated radiotherapy for gynecologic cancer?. Int J Radiat Oncol Biol Phys. 2003, 57: 230-238. 10.1016/S0360-3016(03)00409-7.

    Article  PubMed  Google Scholar 

  32. Aristizabal SA, Steinbronn D, Heusinkveld RS: External beam radiotherapy in cancer of the prostate. The University of Arizona experience. Radiother Oncol. 1984, 1: 309-315.

    Article  CAS  PubMed  Google Scholar 

  33. Asbell SO, Krall JM, Pilepich MV, Baerwald H, Sause WT, Hanks GE, Perez CA: Elective pelvic irradiation in stage A2, B carcinoma of the prostate: analysis of RTOG 77-06. Int J Radiat Oncol Biol Phys. 1988, 15: 1307-1316.

    Article  CAS  PubMed  Google Scholar 

  34. Asbell SO, Martz KL, Shin KH, Sause WT, Doggett RL, Perez CA, Pilepich MV: Impact of surgical staging in evaluating the radiotherapeutic outcome in RTOG #77-06, a phase III study for T1BN0M0 (A2) and T2N0M0 (B) prostate carcinoma. Int J Radiat Oncol Biol Phys. 1998, 40: 769-782. 10.1016/S0360-3016(97)00926-7.

    Article  CAS  PubMed  Google Scholar 

  35. Harisiadis L, Veenema RJ, Senyszyn JJ, Puchner PJ, Tretter P, Romas NA, Chang CH, Lattimer JK, Tannenbaum M: Carcinoma of the prostate: treatment with external radiotherapy. Cancer. 1978, 41: 2131-2142.

    Article  CAS  PubMed  Google Scholar 

  36. Hill DR, Crews QEJ, Walsh PC: Prostate carcinoma: radiation treatment of the primary and regional lymphatics. Cancer. 1974, 34: 156-160.

    Article  CAS  PubMed  Google Scholar 

  37. Neglia WJ, Hussey DH, Johnson DE: Megavoltage radiation therapy for carcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1977, 2: 873-883.

    Article  CAS  PubMed  Google Scholar 

  38. Rosen E, Cassady JR, Connolly J, Chaffey JT: Radiotherapy for prostate carcinoma: the JCRT experience (1968-1978). II. Factors related to tumor control and complications. Int J Radiat Oncol Biol Phys. 1985, 11: 723-730.

    Article  CAS  PubMed  Google Scholar 

  39. Rounsaville MC, Green JP, Vaeth JM, Purdon RP, Heltzel MM: Prostatic carcinoma: limited field irradiation. Int J Radiat Oncol Biol Phys. 1987, 13: 1013-1020.

    Article  CAS  PubMed  Google Scholar 

  40. Zagars GK, von Eschenbach AC, Johnson DE, Oswald MJ: Stage C adenocarcinoma of the prostate. An analysis of 551 patients treated with external beam radiation. Cancer. 1987, 60: 1489-1499.

    Article  CAS  PubMed  Google Scholar 

  41. Zagars GK, von Eschenbach AC, Johnson DE, Oswald MJ: The role of radiation therapy in stages A2 and B adenocarcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1988, 14: 701-709.

    Article  CAS  PubMed  Google Scholar 

  42. Seaward SA, Weinberg V, Lewis P, Leigh B, Phillips TL, Roach M: Improved freedom from PSA failure with whole pelvic irradiation for high-risk prostate cancer. Int J Radiat Oncol Biol Phys. 1998, 42: 1055-1062. 10.1016/S0360-3016(98)00282-X.

    Article  CAS  PubMed  Google Scholar 

  43. Bagshaw MA, Cox RS, Ray GR: Status of radiation treatment of prostate cancer at Stanford University. NCI Monogr. 1988, 47-60.

    Google Scholar 

  44. McGowan DG: The value of extended field radiation therapy in carcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1981, 7: 1333-1339.

    Article  CAS  PubMed  Google Scholar 

  45. Perez CA, Michalski J, Brown KC, Lockett MA: Nonrandomized evaluation of pelvic lymph node irradiation in localized carcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1996, 36: 573-584. 10.1016/S0360-3016(96)00378-1.

    Article  CAS  PubMed  Google Scholar 

  46. Ploysongsang S, Aron BS, Shehata WM, Jazy FK, Scott RM, Ho PY, Morand TM: Comparison of whole pelvis versus small-field radiation therapy for carcinoma of prostate. Urology. 1986, 27: 10-16. 10.1016/0090-4295(86)90197-4.

    Article  CAS  PubMed  Google Scholar 

  47. Rangala N, Cox JD, Byhardt RW, Wilson JF, Greenberg M, Lopes da Conceicao A: Local control and survival after external irradiation for adenocarcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1982, 8: 1909-1914.

    Article  CAS  PubMed  Google Scholar 

  48. Hauschild A, Rosien F, Lischner S: Surgical standards in the primary care of melanoma patients. Onkologie. 2003, 26: 218-222. 10.1159/000071616.

    CAS  PubMed  Google Scholar 

  49. Veronesi U, Paganelli G, Viale G, Luini A, Zurrida S, Galimberti V, Intra M, Veronesi P, Robertson C, Maisonneuve P, Renne G, De Cicco C, De Lucia F, Gennari R: A randomized comparison of sentinel-node biopsy with routine axillary dissection in breast cancer. N Engl J Med. 2003, 349: 546-553. 10.1056/NEJMoa012782.

    Article  PubMed  Google Scholar 

  50. Balkissoon J, Rasgon BM, Schweitzer L: Lymphatic mapping for staging of head and neck cancer. Semin Oncol. 2004, 31: 382-393.

    Article  PubMed  Google Scholar 

  51. Corvin S, Eichhorn K, Wurm T, Sturm W, Bares R, Stenzl A: Radioisotope guided laparoscopic pelvic lymph node dissection - a novel technique for prostate cancer staging. Eur Urol. 2004, 3 Supp: 140-

    Article  Google Scholar 

  52. Nutting CM, Convery DJ, Cosgrove VP, Rowbottom C, Padhani AR, Webb S, Dearnaley DP: Reduction of small and large bowel irradiation using an optimized intensity-modulated pelvic radiotherapy technique in patients with prostate cancer. Int J Radiat Oncol Biol Phys. 2000, 48: 649-656. 10.1016/S0360-3016(00)00653-2.

    Article  CAS  PubMed  Google Scholar 

  53. Adams EJ, Convery DJ, Cosgrove VP, McNair HA, Staffurth JN, Vaarkamp J, Nutting CM, Warrington AP, Webb S, Balyckyi J, Dearnaley DP: Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement. Radiother Oncol. 2004, 70: 1-10. 10.1016/j.radonc.2003.09.004.

    Article  PubMed  Google Scholar 

  54. Mundt AJ, Lujan AE, Rotmensch J, Waggoner SE, Yamada SD, Fleming G, Roeske JC: Intensity-modulated whole pelvic radiotherapy in women with gynecologic malignancies. Int J Radiat Oncol Biol Phys. 2002, 52: 1330-1337. 10.1016/S0360-3016(01)02785-7.

    Article  PubMed  Google Scholar 

Pre-publication history

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Claus Belka.

Additional information

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

CB & UG planned, coordinated and conducted the study. KE, WB, FP took part in designing the study. UG, CB, MA, MBi analyzed the data. UG & CB prepared the manuscript. Medical care was covered by FP, SC, KE, SG, IH, AA, AS, RB, WB, MBa. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Ganswindt, U., Paulsen, F., Corvin, S. et al. Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition. BMC Cancer 5, 91 (2005). https://doi.org/10.1186/1471-2407-5-91

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1471-2407-5-91

Keywords