Original Articles
Improved detection of left main coronary artery disease with attenuation-corrected SPECT

https://doi.org/10.1067/mnc.2000.109454Get rights and content

Abstract

Background. Myocardial perfusion imaging has demonstrated a limited sensitivity as a means of accurately identifying left main (LM) coronary disease. Because regional quantitative perfusion biases are eliminated with attenuation corrected (AC) single photon emission computed tomography (SPECT), as compared with uncorrected (NC) SPECT, we hypothesized that AC SPECT would demonstrate increased diagnostic accuracy for the detection of significant LM coronary stenosis. Methods and Results. We studied 28 patients (23 men, 5 women; mean age, 66 ± 9 years) with significant LM stenoses (≥50%) and 34 control patients (27 men, 7 women; mean age, 65 ± 11 years) with 2-vessel coronary disease. Rest thallium-201 and stress technetium 99m sestamibi SPECT imaging with and without AC were performed, as described earlier. Both AC and NC images were analyzed visually and quantitatively in comparison with corresponding normal databases. A greater sensitivity for detection of an LM defect pattern (64% vs 7%,P = .0009) with equivalent specificity (94% vs 100%, P = not significant) was demonstrated by means of visual analysis of AC SPECT images. More disease was demonstrated in a greater number of territories with AC SPECT images than with NC images (2.14 ± 0.97 for AC images vs 1.43 ± 0.84 for NC images, P = .0001). Similar improvement in the detection of LM disease was shown by means of automated quantitative analysis (57% for AC SPECT vs 14% for NC SPECT,P = .0005), again with no loss in specificity. Conclusions. AC SPECT with the University of Michigan method in consecutive patients with LM stenoses and a select control population with severity matched multivessel coronary disease significantly improved the diagnostic accuracy of myocardial perfusion imaging for the identification of LM coronary disease, compared with uncorrected SPECT. (J Nucl Cardiol 2000;7:639-48.)

References (0)

Cited by (58)

  • Comparison of non-attenuation corrected and attenuation corrected myocardial perfusion SPECT

    2016, Egyptian Journal of Radiology and Nuclear Medicine
    Citation Excerpt :

    Our study also showed considerable improvement in normalcy rate after attenuation correction i.e. from 19% to 74% (Fig. 2). There are other studies that also showed similar results (4,18,26–35). In patients with low likelihood of CAD the normalcy rate can be obtained as high as 98% (15).

  • Advances in Software for Faster Procedure and Lower Radiotracer Dose Myocardial Perfusion Imaging

    2015, Progress in Cardiovascular Diseases
    Citation Excerpt :

    The most common finding in these trials is that, compared to non-AC SPECT, AC significantly improves normalcy rate and specificity for detecting CAD. Although less common, clinical trials have also demonstrated that AC can also significantly improve sensitivity, particularly for detection of left main34 and multiple vessel disease. This is important because of the concern of missing patients with coronary disease in multiple vascular territories that gives rise to the so-called balanced reduction of flow: this represents a confounding factor in misinterpreting studies exhibiting normal perfusion.

  • Lead aVR: Dead or simply forgotten?

    2011, JACC: Cardiovascular Imaging
  • Coronary Artery Disease Detection: Exercise Stress SPECT. Exercise Stress SPECT.

    2010, Clinical Nuclear Cardiology: State of the Art and Future Directions
View all citing articles on Scopus