Elsevier

Journal of Nuclear Cardiology

Volume 5, Issue 3, May–June 1998, Pages 313-331
Journal of Nuclear Cardiology

Review
Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT

https://doi.org/10.1016/S1071-3581(98)90133-7Get rights and content

Abstract

Thallium-201 has been used extensively as a myocardial perfusion agent and to assess myocardial viability. Unlike other 99mTc-labeled agents such as 99mTc-sestamibi and 99mTc-tetrofosmine, the regional concentration of 201T1varies with time, and its kinetics make it a potential candidate for estimating absolute physiologic parameters with kinetic model analysis. This article outlines a strategy for quantitative assessment of regional myocardial blood flow in man using 201Tl and dynamic single photon emission computed tomography (SPECT) . Quantitatively accurate SPECT images that are proportional to the true radioactivity distribution are prerequisites for model-based kinetic analysis. Our technique for quantitative SPECT includes ordered-subset maximum likelihood—expectation maximization (ML-EM) reconstruction with transmission data—based attenuation correction and transmission-dependent convolution subtraction scatter correction. A three-compartment model was found to reproduce the observed regionaltime-activity curves well, and dog experiments demonstrated that influx rate constant (K1) sc estimated from the dynamic SPECT data correlated well with absolute myocardial blood flow determined by in vitro microspheres for a physiologically wide range of flows. Several possible strategies for simplifying the study procedures, without compromising accuracy, are also presented, which should make absolute quantitation of regional myocardial blood flow feasible using 201Tl and a conventional SPECT camera in a clinical setting.

References (85)

  • HR Schelbert et al.

    Considerations of 201T1as a myocardial radionuclide imaging agent in man

    Invest Radiol

    (1976)
  • HF Weich et al.

    The extraction of thallium-201 by the myocardium

    Circulation

    (1977)
  • RD Okada et al.

    Thallium-201 kinetics in nonischemic canine myocardium

    Circulation

    (1982)
  • RD Okada et al.

    Myocardial kinetics of thallium-201 after dipyridamole infusion in normal canine myocardium and in myocardium distal to a stenosis

    J Clin Invest

    (1982)
  • JG Llaurado et al.

    Distribution of thallium201 injected into rats following stress: imaging organ to plasma uptake ratios, and myocardial kinetics

    J Nucl Med

    (1978)
  • JG Llaurado et al.

    Partition of thallium-201 in isolated myocardial tissue of rats previously injected at rest or after exercise

    J Nucl Med

    (1979)
  • JG Llaurado et al.

    Effects of exercise and distribution of K-43 and T1-201 in isolated myocardium: concise communication

    J Nucl Med

    (1981)
  • E Lebowitz et al.

    Thallium-201 for medical use. I

    J Nucl Med

    (1975)
  • HL Atkins et al.

    Thallium-201 for medical use, part 3: human distribution and physical imaging properties

    J Nucl Med

    (1977)
  • PR Bradley-Moore et al.

    Thallium-201 for medical use, II: biologic behavior

    J Nucl Med

    (1975)
  • MS Rosenthai et al.

    Quantitative SPECT imaging: a review and recommendations by the Focus Committee of the Society of Nuclear Medicine Computer and Instrumentation Council

    J Nucl Med

    (1995)
  • P Tan et al.

    A scanning line source for simultaneous emission and transmission measurements in SPECT

    J Nucl Med

    (1993)
  • SR Meikle

    Quantitative emission computed tomography using simultaneous emission and transmission measurements

  • M Ljungberg et al.

    Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions

    J Nucl Med

    (1990)
  • SR Meikle et al.

    A transmission dependent method for scatter correction in SPECT

    J Nucl Med

    (1994)
  • DL Bailey et al.

    A quantitative SPECT regime

  • RJ Jaszczak et al.

    Improved SPECT quantitation using compensation for scattered photons

    J Nucl Med

    (1984)
  • RJ Jaszczak et al.

    Scatter compensation techniques for SPECT

    IEEE Trans Nucl Sci

    (1985)
  • MA King et al.

    A dual-photopeak window method for scatter correction

    J Nucl Med

    (1992)
  • K Ogawa et al.

    A practical method for positiondependent Compton-scatter correction in single photon emission CT

    IEEE Trans Med Imag

    (1991)
  • K Ogawa et al.

    Accurate scatter correction in single photon emission CT

    Ann Nucl Med Sci

    (1994)
  • D Gagnon et al.

    Introduction to holospectral imaging in nuclear medicine for scatter correction

    IEEE Trans Med Imag

    (1989)
  • I Buvat et al.

    Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations

    J Nucl Med

    (1995)
  • B Axelsson et al.

    Subtraction of Compton-scattered photons in single-photon emission computerized tomography

    J Nucl Med

    (1984)
  • M Ljungberg et al.

    Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a Monte Carlo study

    J Nucl Med

    (1991)
  • JE Bowsher et al.

    Treatment of Compton scattering in maximum likelihood expectation-maximization reconstructions of SPECT images

    J Nucl Med

    (1991)
  • FJ Beckman et al.

    Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation

    IEEE Trans Med Imag

    (1996)
  • T Ichihara et al.

    Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT

    J Nucl Med

    (1993)
  • Y Narita et al.

    Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT

    Phys Med Biol

    (1996)
  • Y Narita et al.

    Monte Carlo evaluation of accuracy and noise properties of two scatter correction methods for 201T1 cardiac SPECT

    IEEE Trans Nucl Sci

    (1997)
  • BMW Tsui et al.

    Quantative cardiac SPECT with reduced degradation due to patient anatomy

    IEEE Trans Nucl Sci

    (1994)
  • HM Hudson et al.

    Accelerated image reconstruction using ordered subsets of projection data

    IEEE Trans Med Imag

    (1994)
  • Cited by (63)

    • Quantitative Assessment of Myocardial Blood Flow with SPECT

      2015, Progress in Cardiovascular Diseases
      Citation Excerpt :

      Several researches suggested that it is possible to quantify CFR with this approach (Table 3). In particular, there are studies using dynamic planar scintigraphy in humans39–44 or dynamic SPECT in animals.34,45,46 The method used in these investigations is potentially open to implementation in most nuclear cardiology laboratories, and it could be adapted for general application (Fig 2).

    View all citing articles on Scopus

    Supported by a research grant for cardiovascular diseases (8C-5, 1996–1998) from the Ministry of Health and Welfare.

    View full text