Skip to main content
Log in

Fully automated and simplified radiosynthesis of [18F]-3′-deoxy-3′-fluorothymidine using anhydro precursor and single neutral alumina column purification

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

[18F]-3′-deoxy-3′-fluorothymidine ([18F]FLT) is an established positron emission tomograph (PET)—radiopharmaceutical to study cell-proliferation rate in tumors. Very low practical yield, uncertain and time-consuming high performance liquid chromatography (HPLC) purification, are the main obstacles for the routine use of [18F]FLT in clinical PET. To obviate these difficulties, we have developed a fully automated radiosynthesis procedure for [18F]FLT using 5′-O-(4,4′-dimethoxytriphenylmethyl)-2,3′-anhydro-thymidine (DMTThy) and simplified single neutral alumina column purification. The [18F]FLT yield was 8.48 ± 0.93% (n = 5) (without radioactive decay correction) in a synthesis time of 68 ± 3 min. The radiochemical purity was greater than 95% as confirmed by analytical HPLC using reference standard FLT and also free of non-radioactive impurity. Soluble aluminum in the final product was much below the permissible limits. Di-methyl sulfoxide (DMSO), the reaction medium, could be detected in the final product in trace amounts, well below the permissible levels. The synthesized [18F]FLT was sterile and bacterial endotoxin free by appropriate tests. PET imaging study in normal rabbits showed distinct localization of [18F]FLT in organs having rapid cell division rate like bone marrow, guts and snout and the excretion was through the renal route. There were no significant uptakes in bone and brain. The former finding confirms the in vivo stability of the [18F]FLT. This simplified radiosynthesis procedure can easily be adapted in any commercial or indigenous [18F]FDG synthesis module for routine [18F]FLT synthesis without the need of additional automation for HPLC purification.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Scheme 1
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Barthel H, Perumal M, Latigo J, He Q, Bardy F, Luthara SK, Pierec PM (2005) Eur J Nucl Med Mol Imaging 32:257

    Article  CAS  Google Scholar 

  2. Been LB, Suurmeijer AJH, Cobben DCP, Jager PL, Hoekstra HJ, Elsinga PH (2004) Eur J Nucl Med Mol Imaging 31:1659

    Article  Google Scholar 

  3. Buck AK, Schirrmeister H, Hetzel M, Von Der Heide M, Halter G, Gatting G, Mattfeldt T, Liewald F, Reske SN, Neumaier B (2002) Cancer Res 62:3331

    CAS  Google Scholar 

  4. Chen W, Cloughesy T, Kamadar N, Satyamurthy N, Bergoneider M, Liau L, Mischel P, Czernin J, Phelps ME, Silverman DHS (2005) J Nucl Med 46:945

    CAS  Google Scholar 

  5. Shields AF, Grierson JR, Dohmen BM, Machulla HJ, Stayanoff JC, Lawhorn-crews JM, Obradovich JE, Muzik O, Mangner TJ (1998) Nat Med 4:1334

    Article  CAS  Google Scholar 

  6. Shields AF, Lim K, Grierson J, Link K, Krohn KA (1990) J Nucl Med 31:337

    CAS  Google Scholar 

  7. Wilson IK, Chatterjee S, Wolf W (1991) J Fluor Chem 55:283

    Article  CAS  Google Scholar 

  8. Grierson JR, Shields AF (2000) Nucl Med Biol 27:143

    Article  CAS  Google Scholar 

  9. Wodarski C, Eisenbarth J, Naber K, Henze M, Haberkorn U, Eisenhut M (2000) J Labelled Comp Radiopharm 43:1211–1218

    Article  CAS  Google Scholar 

  10. Martin SJ, Eisenbarth JA, Wagner-Utermann U, Mier W, Henze M, Prizkow H, Haberkorn U, Eisenhut M (2002) Nucl Med Biol 29:263–273

    Article  CAS  Google Scholar 

  11. Machulla HJ, Blocher A, Kuntzsch M, Piert M, Wei R, Grierson JR (2000) J Radioanal Nucl Chem 243:843

    Article  CAS  Google Scholar 

  12. Blocher A, Kunzsch R, Wei R, Machulla HJ (2002) J Radioanal Nucl Chem 251:55

    Article  CAS  Google Scholar 

  13. Windhorst AD, Klein PJ, Eisenbarth J, Oeser T, Kruijer PS, Eisenhut M (2008) Nucl Med Biol 35:413

    Article  CAS  Google Scholar 

  14. Nandy SK, Rajan MGR, Korde A, Chaudhari PR (2007) J Labelled Comp Radiopharm 50:S121

    Google Scholar 

  15. Nandy SK, Krishnamurthy NV, Rajan MGR (2009) J Radioanal Nucl Chem. doi:10.1007/s10967-0322-1

  16. Tewson TJ, Paulsen A, El-Shafie F (2003) J Labelled Comp Radiopharm 46:S222

    Google Scholar 

  17. Nakao R, Kida T, Suzuki B (2005) Appl Radiat Isot 62:889

    Article  CAS  Google Scholar 

  18. Demirtas I, Buyukkidin S, Elmastas M (2002) Turk J Chem 26:889

    CAS  Google Scholar 

  19. www.sigmaaldrich.com/catalogue (Product CAS Number: 67-68-5)

  20. Choi MF, Hawkins P (1995) Spectrochim Acta 51A:579

    CAS  Google Scholar 

  21. Impurities: residual solvents in new veterinary medicinal products, active substances and excipients, VICH Topic GL18 (Impurities Solvents), June 2000 (Recommended for Implementation at Step 7 of the VICH Process)

  22. Salskov A, Tammisetli S, Grierson J, Vesselle H (2007) Semin Nucl Med 37:429

    Article  Google Scholar 

Download references

Acknowledgements

Thanks to Mr. B. P. Tiwari, Radiation Medicine Centre, Bhabha Atomic Research Centre (BARC) for helping in PET imaging studies. Special thanks to Mr. Arpit Mitra, Medical Cyclotron Facility, Board of Radiation and Isotope Technology (BRIT), for analyzing the samples for sterility and BET.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. G. R. Rajan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nandy, S.K., Rajan, M.G.R. Fully automated and simplified radiosynthesis of [18F]-3′-deoxy-3′-fluorothymidine using anhydro precursor and single neutral alumina column purification. J Radioanal Nucl Chem 283, 741–748 (2010). https://doi.org/10.1007/s10967-009-0429-4

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-009-0429-4

Keywords

Navigation